Rationale for the Design and Use of Pure Titanium Internal Fixation Plates

Author(s):  
FW Baumgart ◽  
SM Perren
2014 ◽  
Vol 7 (3) ◽  
pp. 218-223 ◽  
Author(s):  
Peter Aquilina ◽  
William C.H. Parr ◽  
Uphar Chamoli ◽  
Stephen Wroe ◽  
Philip Clausen

The most stable pattern of internal fixation for mandibular condyle fractures is an area of ongoing discussion. This study investigates the stability of three patterns of plate fixation using readily available, commercially pure titanium implants. Finite element models of a simulated mandibular condyle fracture were constructed. The completed models were heterogeneous in bone material properties, contained approximately 1.2 million elements and incorporated simulated jaw adducting musculature. Models were run assuming linear elasticity and isotropic material properties for bone. No human subjects were involved in this investigation. The stability of the simulated condylar fracture reduced with the different implant configurations, and the von Mises stresses of a 1.5-mm X-shaped plate, a 1.5-mm rectangular plate, and a 1.5-mm square plate (all Synthes (Synthes GmbH, Zuchwil, Switzerland) were compared. The 1.5-mm X plate was the most stable of the three 1.5-mm profile plate configurations examined and had comparable mechanical performance to a single 2.0-mm straight four-hole plate. This study does not support the use of rectangular or square plate patterns in the open reduction and internal fixation of mandibular condyle fractures. It does provide some support for the use of a 1.5-mm X plate to reduce condylar fractures in selected clinical cases.


Injury ◽  
1994 ◽  
Vol 25 (2) ◽  
pp. 87-89 ◽  
Author(s):  
K.M. Pfeiffer ◽  
J. Brennwald ◽  
U. Büchler ◽  
D. Hanel ◽  
J. Jupiter ◽  
...  

Author(s):  
B. B. Rath ◽  
J. E. O'Neal ◽  
R. J. Lederich

Addition of small amounts of erbium has a profound effect on recrystallization and grain growth in titanium. Erbium, because of its negligible solubility in titanium, precipitates in the titanium matrix as a finely dispersed second phase. The presence of this phase, depending on its average size, distribution, and volume fraction in titanium, strongly inhibits the migration of grain boundaries during recrystallization and grain growth, and thus produces ultimate grains of sub-micrometer dimensions. A systematic investigation has been conducted to study the isothermal grain growth in electrolytically pure titanium and titanium-erbium alloys (Er concentration ranging from 0-0.3 at.%) over the temperature range of 450 to 850°C by electron microscopy.


Author(s):  
D.M. Vanderwalker

There is a fundamental interest in electrochemical fusion of deuterium in palladium and titanium since its supposed discovery by Fleischmann and Pons. Their calorimetric experiments reveal that a large quantity of heat is released by Pd after hours in a cell, suggesting fusion occurs. They cannot explain fusion by force arguments, nor can it be an exothermic reaction on the formation of deuterides because a smaller quantity of heat is released. This study examines reactions of deuterium in titanium.Both iodide titanium and 99% pure titanium samples were encapsulated in vacuum tubes, annealed for 2h at 800 °C. The Ti foils were charged with deuterium in a D2SO4 D2O solution at a potential of .45V with respect to a calomel reference junction. Samples were ion beam thinned for transmission electron microscopy. The TEM was performed on the JEOL 200CX.The structure of D charged titanium is α-Ti with hexagonal and fee deuterides.