scholarly journals Early Results after Aortic Valve Replacement Using Last Generation Bioprosthetic Aortic Valve

2021 ◽  
Vol 24 (6) ◽  
pp. E598-E962
Author(s):  
Dritan Useini ◽  
Markus Schlömicher ◽  
Peter Haldenwang ◽  
Hamid Naraghi ◽  
Vadim Moustafine ◽  
...  

Introduction: Few data are available about the newest generation surgical bioprosthesis. We aimed to evaluate early clinical and hemodynamic outcomes after using the INSPIRIS RESILIA aortic valve (Edwards Lifesciences, Irvine, California, USA). Methods: Between July 2018 and April 2021, 80 patients underwent aortic valve replacement receiving the INSPIRIS RESILIA aortic valve at our institution. Primary outcomes were the composite of early mortality, stroke, and myocardial infarction. Secondary outcomes were hemodynamic performances of the valve, paravalvular leakage, and new pacemaker implantation. Results: The mean age of the study population was 60.6 ± 8.3 years. The mean Society of Thoracic Surgery-Predicted Risk of Mortality score was 2.9 ± 1.7%. In 43.7% of the patients, concomitant surgery was performed. The in-hospital mortality, all-stroke, and myocardial infarction rates were 2.5%, 1.2%, and 1.2%, respectively. No valve was explanted and no redo was performed. The mean postoperative trans-prosthetic gradient at discharge was 10.2 ± 4.1 mm Hg. There was no need for new pacemaker implantation. We registered only two cases with minimal (trace) paravalvular leakage. Conclusion: The use of the INSPIRIS RESILIA aortic valve in a young, low-risk population is safe and associated with very good early clinical and hemodynamic outcomes.

Perfusion ◽  
2021 ◽  
pp. 026765912110232
Author(s):  
Serik Aitaliyev ◽  
Egle Rumbinaitė ◽  
Karolina Mėlinytė-Ankudavičė ◽  
Rokas Nekrošius ◽  
Vytenis Keturakis ◽  
...  

Introduction: Patient-prosthesis mismatch (PPM) has been associated with numerous short- and long-term adverse events. This study aimed to evaluate the effect of PPM on early postoperative results after aortic valve replacement (AVR) in daily practice. Methods: In this single-centre retrospective study, 150 non-consecutive patients from March 2019 to January 2020 with clinically indicated AVR with/without concomitant surgery were analysed. The study protocol included operative mortality, complication rate, and pre- and postoperative echocardiographic data. PPM was considered severe with indexed effective orifice area at <0.65 cm2/m2, moderate at 0.65–0.85 cm2/m2 and none at >0.85 cm2/m2. Results: Moderate PPM was observed in 16 patients (10.6%). No patient had severe PPM. PPM was not related to early mortality ( r = 0.40, p = 0.630), intra- ( r = −0.076, p = 0.352) and postoperative ( r = −0.0134, p = 0.102) events. Conclusion: In this study, moderate PPM was a frequent finding after AVR, whereas severe PPM was not observed. PPM did not affect the early results after AVR. A long-term follow-up study in a large patient population is required to assess the actual influence of residual PPM.


2020 ◽  
Vol 58 (5) ◽  
pp. 1045-1053 ◽  
Author(s):  
Alexander Horke ◽  
Igor Tudorache ◽  
Günther Laufer ◽  
Martin Andreas ◽  
Jose L Pomar ◽  
...  

Abstract OBJECTIVES Decellularized aortic homografts (DAH) may provide an additional aortic valve replacement option for young patients due to their potential to overcome the high early failure rate of conventional allogenic and xenogenic aortic valve prostheses. METHODS A prospective, European Union-funded, single-arm, multicentre, safety study was conducted in 8 centres evaluating non-cryopreserved DAH for aortic valve replacement. RESULTS One hundred and forty-four patients (99 male) were prospectively enrolled between October 2015 and October 2018, mean age 33.6 ± 20.8 years; 45% had undergone previous cardiac operations. Mean implanted DAH diameter 22.6 ± 2.4 mm and mean durations for the operation, cardiopulmonary bypass and cross-clamp were 341 ± 140, 174 ± 80 and 126 ± 43 min, respectively. There were 2 early deaths (1 LCA thrombus on day 3 and 1 ventricular arrhythmia 5 h postop) and 1 late death due to endocarditis 4 months postoperatively, resulting in a total mortality of 2.08%. One pacemaker implantation was necessary and 1 DAH was successfully repaired after 6 weeks for early regurgitation following subcoronary implantation. All other DAH were implanted as a free-standing root. After a mean follow-up of 1.54 ± 0.81 years, the primary efficacy end points peak gradient (mean 11.8 ± 7.5 mmHg) and regurgitation (mean 0.42 ± 0.49, grade 0–3) were excellent. At 2.5 years, freedom from explantation/endocarditis/bleeding/stroke was 98.4 ± 1.1%/99.4 ± 0.6%/99.1 ± 0.9%/99.2 ± 0.8%, respectively, with results almost identical to those in an age-matched Ross operation cohort of 212 patients (mean age 34 years) despite DAH patients having undergone &gt;2× more previous procedures. CONCLUSIONS The initial results of the prospective multicentre ARISE trial show DAH to be safe for aortic valve replacement with excellent haemodynamics in the short follow-up period.


2011 ◽  
Vol 14 (4) ◽  
pp. 232 ◽  
Author(s):  
Orlando Santana ◽  
Joseph Lamelas

<p><b>Objective:</b> We retrospectively evaluated the results of an edge-to-edge repair (Alfieri stitch) of the mitral valve performed via a transaortic approach in patients who were undergoing minimally invasive aortic valve replacement.</p><p><b>Methods:</b> From January 2010 to September 2010, 6 patients underwent minimally invasive edge-to-edge repair of the mitral valve via a transaortic approach with concomitant aortic valve replacement. The patients were considered to be candidates for this procedure if they were deemed by the surgeon to be high-risk for a double valve procedure and if on preoperative transesophageal echocardiogram the mitral regurgitation jet originated from the middle portion (A2/P2 segments) of the mitral valve.</p><p><b>Results:</b> There was no operative mortality. Mean cardiopulmonary bypass time was 137 minutes, and mean cross-clamp time was 111 minutes. There was a significant improvement in the mean mitral regurgitation grade, with a mean of 3.8 preoperatively and 0.8 postoperatively. The ejection fraction remained stable, with mean preoperative and postoperative ejection fractions of 43.3% and 47.5%, respectively. Follow-up transthoracic echocardiograms obtained at a mean of 33 days postoperatively (range, 8-108 days) showed no significant worsening of mitral regurgitation.</p><p><b>Conclusion:</b> Transaortic repair of the mitral valve is feasible in patients undergoing minimally invasive aortic valve replacement.</p>


Author(s):  
Luca Koechlin ◽  
Friedrich S. Eckstein

Abstract Purpose of the Review The aim of this article is to describe the technique of aortic valve neocuspidization using autologous pericardium (AVNeo, “OZAKI procedure”) in adult cardiac surgery, to analyze recent findings, and to discuss benefits and limitations of this technique. Recent Findings Potential benefits of this technique include excellent hemodynamic performances, minimal use of foreign material, low rates of permanent pacemaker implantation, and omission of oral anticoagulation. However, data regarding the durability of the procedure are hitherto limited, and the procedure is associated with a higher complexity compared to aortic valve replacement. Summary AVNeo using autologous pericardium in adult cardiac surgery is a promising technique providing several benefits. However, there is a major unmet need for more data, especially regarding long-term durability. Thus, based on currently available data, we recommend careful patient selection within the heart team and shared decision-making with the informed patient.