Nonlinear Predictive Control for Maximum Power Point Tracking and Unity Power Factor of a Three Phase Grid Connected PV System

2018 ◽  
Vol 11 (3) ◽  
pp. 133
Author(s):  
Mohammed El Malah ◽  
Abdellfattah Ba-razzouk ◽  
M’hammed Guisser ◽  
Elhassane Abdelmounim ◽  
Mhamed Madark ◽  
...  
Energies ◽  
2020 ◽  
Vol 13 (6) ◽  
pp. 1304 ◽  
Author(s):  
Miaomiao Ma ◽  
Xiangjie Liu ◽  
Kwang Y. Lee

This paper proposes a maximum power point tracking (MPPT) and voltage regulation method based on model predictive control (MPC) for the two-stage grid-tied photovoltaic (PV) system, which can achieve MPPT and output voltage regulation of a PV system simultaneously. The MPPT algorithm based on MPC is implemented in a DC-DC boost converter. The reference voltage at maximum power point is obtained by dual step Incremental Conductance (I&C) algorithm under the rapidly varying illumination intensity, and the MPPT controller only needs to minimize one cost function of PV current, without pulse width modulation (PWM) module. To inject the generated PV power into the grid with high quality, this paper designs voltage regulation controller based on MPC to maintain the output voltage of the PV system at the desired value. The MPC controller outputs the optimal duty signal with the input and state constraints in the inner loop, and the PI controller in the outer loop is designed to improve the dynamic performance. The proposed method based on MPC was demonstrated using the SimPower systems tool in MATLAB/Simulink. Analysis and simulation results for the PV system show possible improvements on the closed-loop performance such as fast response and low overshoot.


Author(s):  
Hicham Bahri ◽  
Mohamed Aboulfatah ◽  
M’hammed Guisser ◽  
Elhassane Abdelmounim ◽  
Mohammed El Malah

This paper presents a robust control strategy for a grid connected photovoltaic system with a boost converter by using an integral Backstepping method based on a nonlinear state model, which guarantees the Lyapunov stability of the global system. The system has tracked precisely the maximum power point, with a very fast response and the unit power factor has been observed under different atmospheric conditions. Moreover, the best advantage of the controller is that it’s a good corrector of the grid perturbation and system parameter disturbance. The simulation result has demonstrated the performance of this strategy.


Author(s):  
Pradeep Rai ◽  
Roshan Nayak

This paper proposes a nonlinear control methodology for three phase grid connected of PV generator. It consists of a PV arrays; a voltage source inverter, a grid filter and an electric grid. The controller objectives are threefold: i) ensuring the Maximum power point tracking (MPPT) in the side of PV panels, ii) guaranteeing a power factor unit in the side of the grid, iii) ensuring the global asymptotic stability of the closed loop system. Based on the nonlinear model of the whole system, the controller is carried out using a Lyapunov approach. It is formally shown, using a theoretical stability analysis and simulation results that the proposed controller meets all the objectives.


Sign in / Sign up

Export Citation Format

Share Document