scholarly journals Association between the systolic arterial blood pressure level and inter-arm asymmetry

2014 ◽  
Vol 95 (3) ◽  
pp. 472-474
Author(s):  
P I Petrov

Aim. To determine the association between the systolic arterial blood pressure level and the inter-arm asymmetry measurements in healthy individuals. Methods. 580 healthy volunteers aged 20 to 60 years (401 females, 179 males) were included in the study. Arterial blood pressure was measured in both left and right wrists using an automatic blood pressure sensor with the detector of hand position in a quiet, comfortable environment. Depending on the systolic arterial blood pressure level on the left arm, subjects were distributed to 5 groups: the 1st - blood pressure of 99 mm Hg and lower; 2nd - 100-119; 3rd - 120-129; 4th - 130-139; 5th -140 and over. Each group were further subdivided to 3 subgroups depending on the inter-arm blood pressure level asymmetry (difference of blood pressure levels on both arms): 1st - symmetry, 2nd - acceptable asymmetry (not exceeding 15 mm Hg), 3rd - abnormal asymmetry (16 mm Hg and over). Results. The major part of the examined subjects had systolic arterial blood pressure level between 100 and 119 mm Hg, systolic blood pressure below 99 mm Hg was registered more rarely. Among 580 examined subjects, abnormal asymmetry was more frequently seen in patients with blood pressure below 99 mm Hg and exceeding 140 mm Hg, the lowest frewuency was in the group with blood pressure between 120 and 129 mm Hg. The right arm was the dominating arm for the asymmetry in subjects with blood pressure below 119 mm Hg, in other cases the dominating arm was not determined. Conclusion. The study demonstrates the presence of vascular inter-arm asymmetry in systolic blood pressure in individuals who perceive themselves as healthy. Inter-arm asymmetry depended on the level of systolic arterial blood pressure.

1984 ◽  
Vol 6 (1) ◽  
pp. 33-39 ◽  
Author(s):  
G. Vachtsevanos ◽  
C. Kalaitzakis ◽  
N. Papamarkos ◽  
G. Ziakas ◽  
K. Economou ◽  
...  

1941 ◽  
Vol 74 (1) ◽  
pp. 29-40 ◽  
Author(s):  
Philip D. McMaster

Advantage has been taken of the relative transparency of the claw of the mouse to devise a method, here described, to measure the blood pressure in the animal's leg. Direct measurements of the systolic blood pressure from the carotid arteries of anesthetized mice have also been made. Simultaneous blood pressure readings by both these methods applied to the same animal showed close agreement. The systolic pressure ranged from 60 to 126 mm. Hg, according to the conditions.


2003 ◽  
Vol 98 (6) ◽  
pp. 1338-1344 ◽  
Author(s):  
Gilles Boccara ◽  
Alexandre Ouattara ◽  
Gilles Godet ◽  
Eric Dufresne ◽  
Michèle Bertrand ◽  
...  

Background Terlipressin, a precursor that is metabolized to lysine-vasopressin, has been proposed as a drug for treatment of intraoperative arterial hypotension refractory to ephedrine in patients who have received long-term treatment with renin-angiotensin system inhibitors. The authors compared the effectiveness of terlipressin and norepinephrine to correct hypotension in these patients. Methods Among 42 patients scheduled for elective carotid endarterectomy, 20 had arterial hypotension following general anesthesia that was refractory to ephedrine. These patients were the basis of the study. After randomization, they received either 1 mg intravenous terlipressin (n = 10) or norepinephrine infusion (n = 10). Beat-by-beat recordings of systolic arterial blood pressure and heart rate were stored on a computer. The intraoperative maximum and minimum values of blood pressure and heart rate, and the time spent with systolic arterial blood pressure below 90 mmHg and above 160 mmHg, were used as indices of hemodynamic stability. Data are expressed as median (95% confidence interval). Results Terlipressin and norepinephrine corrected arterial hypotension in all cases. However, time spent with systolic arterial blood pressure below 90 mmHg was less in the terlipressin group (0 s [0-120 s] vs. 510 s [120-1011 s]; P < 0.001). Nonresponse to treatment (defined as three boluses of terlipressin or three changes in norepinephrine infusion) occurred in zero and eight cases (P < 0.05), respectively. Conclusions In patients who received long-term treatment with renin-angiotensin system inhibitors, intraoperative refractory arterial hypotension was corrected with both terlipressin and norepinephrine. However, terlipressin was more rapidly effective for maintaining normal systolic arterial blood pressure during general anesthesia.


PEDIATRICS ◽  
1985 ◽  
Vol 75 (6) ◽  
pp. 1081-1090
Author(s):  
Ronald M. Lauer ◽  
Trudy L. Burns ◽  
William R. Clarke

Blood pressure was assessed in 4,207 children, aged 5 to 18 years, examined in the schools of Muscatine, Iowa during 1981. Overall, 69.9% of the age-sex-specific quintiles and height-sex-specific quintiles of systolic blood pressure were identical. In only 1.0% of children did these quintiles differ by more than one. Children whose blood pressure was in the highest quintile for both age and height were more obese than their peers. Those whose blood pressure was high for age but not for height were proportionately taller and heavier than their age peers. Children whose blood pressure was high for height but not for age were older, shorter, and lighter. Thus, having precocious levels of blood pressure for age during childhood is associated with excessive body weight or precocious height, whereas having high blood pressure for height but not for age is associated with being short for age. The latter suggests that age may be a factor independent of height and weight affecting blood pressure level in childhood. These relationships of body size and age to blood pressure must be considered when evaluating children's blood pressure levels in the clinical setting, and a technique for doing so is presented.


PEDIATRICS ◽  
1982 ◽  
Vol 69 (5) ◽  
pp. 583-586
Author(s):  
Ronald N. Goldberg ◽  
Steven L. Goldman ◽  
R. Eugene Ramsay ◽  
Rosalyn Feller

In experimental animals neurologic damage may occur during seizure activity whether the seizure is accompanied by motor activity and hypoxemia or whether the animal is paralyzed and normoxemic. These findings suggest that it may be important to detect seizure activity in the paralyzed neonate. Nine infants who were mechanically ventilated and paralyzed with pancuronium had their condition diagnosed as seizure activity. Vital signs were continuously monitored and six infants had either oxygen saturation or transcutaneous oxygen measured during seizure activity. For the group as a whole, rhythmic fluctuations in vital signs, cardiac rhythm, and oxygenation occurred every four minutes (range one to seven minutes) and lasted two minutes (range one to four minutes). In seven patients whose seizures were not accompanied by cardiac arrhythmias the following mean increases were noted: systolic arterial blood pressure, 15 mm Hg (range 7 to 36 mm Hg); heart rate, ten beats per minute (-11 to 30/min); oxygen saturation, 12% (range 4% to 20%); and transcutaneous oxygen, 31 mm Hg (range 14 to 45 mm Hg). Seizures in the two patients with cardiac arrhythmias were accompanied by a decrease in systolic arterial blood pressure of 27 mm Hg (range 15 to 40 mm Hg) and in oxygen saturation of 24% (range 20% to 28%). The presence of rhythmic fluctuation in vital signs and oxygenation should alert the physician to the possibility of seizure activity in the paralyzed neonate.


Sensors ◽  
2020 ◽  
Vol 20 (14) ◽  
pp. 3829
Author(s):  
Muammar Sadrawi ◽  
Yin-Tsong Lin ◽  
Chien-Hung Lin ◽  
Bhekumuzi Mathunjwa ◽  
Shou-Zen Fan ◽  
...  

Hypertension affects a huge number of people around the world. It also has a great contribution to cardiovascular- and renal-related diseases. This study investigates the ability of a deep convolutional autoencoder (DCAE) to generate continuous arterial blood pressure (ABP) by only utilizing photoplethysmography (PPG). A total of 18 patients are utilized. LeNet-5- and U-Net-based DCAEs, respectively abbreviated LDCAE and UDCAE, are compared to the MP60 IntelliVue Patient Monitor, as the gold standard. Moreover, in order to investigate the data generalization, the cross-validation (CV) method is conducted. The results show that the UDCAE provides superior results in producing the systolic blood pressure (SBP) estimation. Meanwhile, the LDCAE gives a slightly better result for the diastolic blood pressure (DBP) prediction. Finally, the genetic algorithm-based optimization deep convolutional autoencoder (GDCAE) is further administered to optimize the ensemble of the CV models. The results reveal that the GDCAE is superior to either the LDCAE or UDCAE. In conclusion, this study exhibits that systolic blood pressure (SBP) and diastolic blood pressure (DBP) can also be accurately achieved by only utilizing a single PPG signal.


1998 ◽  
Vol 275 (1) ◽  
pp. H139-H144 ◽  
Author(s):  
Olivier Régrigny ◽  
Philippe Delagrange ◽  
Elizabeth Scalbert ◽  
Jeffrey Atkinson ◽  
Isabelle Lartaud-Idjouadiene

Because melatonin is a cerebral vasoconstrictor agent, we tested whether it could shift the lower limit of cerebral blood flow autoregulation to a lower pressure level, by improving the cerebrovascular dilatory reserve, and thus widen the security margin. Cerebral blood flow and cerebrovascular resistance were measured by hydrogen clearance in the frontal cortex of adult male Wistar rats. The cerebrovasodilatory reserve was evaluated from the increase in the cerebral blood flow under hypercapnia. The lower limit of cerebral blood flow autoregulation was evaluated from the fall in cerebral blood flow following hypotensive hemorrhage. Rats received melatonin infusions of 60, 600, or 60,000 ng ⋅ kg−1 ⋅ h−1, a vehicle infusion, or no infusion ( n= 9 rats per group). Melatonin induced concentration-dependent cerebral vasoconstriction (up to 25% of the value for cerebrovascular resistance of the vehicle group). The increase in vasoconstrictor tone was accompanied by an improvement in the vasodilatory response to hypercapnia (+50 to +100% vs. vehicle) and by a shift in the lower limit of cerebral blood flow autoregulation to a lower mean arterial blood pressure level (from 90 to 50 mmHg). Because melatonin had no effect on baseline mean arterial blood pressure, the decrease in the lower limit of cerebral blood flow autoregulation led to an improvement in the cerebrovascular security margin (from 17% in vehicle to 30, 55, and 55% in the low-, medium-, and high-dose melatonin groups, respectively). This improvement in the security margin suggests that melatonin could play an important role in the regulation of cerebral blood flow and may diminish the risk of hypoperfusion-induced cerebral ischemia.


2004 ◽  
Vol 286 (6) ◽  
pp. H2408-H2415 ◽  
Author(s):  
Steven E. Whitesall ◽  
Janet B. Hoff ◽  
Alan P. Vollmer ◽  
Louis G. D'Alecy

Radiotelemetry of mouse blood pressure accurately monitors systolic pressure, diastolic pressure, heart rate, and locomotor activity but requires surgical implantation. Noninvasive measurements of indirect systolic blood pressure have long been available for larger rodents and now are being reported more frequently for mice. This study compared mouse systolic arterial blood pressure measurements using implanted radiotelemetry pressure transducer with simultaneous tail-cuff measurements in the same unanesthetized mice. The pressure range for comparison was extended by inducing experimental hypertension or by observations of circadian elevations between 3 AM and 6 AM. Both trained and untrained tail-cuff operators used both instruments. Every effort was made to follow recommended manufacturer's instructions. With the initial flow-based tail-cuff instrument, we made 671 comparisons (89 sessions) and found the slope of the linear regression to be 0.118, suggesting poor agreement. In an independent assessment, 277 comparisons (35 sessions) of radiotelemetry measurements with the pulse based tail-cuff instrument were made. The slope of the linear regression of the simultaneous measurements of systolic pressures was 0.98, suggesting agreement. Bland-Altman analysis also supported our interpretation of the linear regression. Thus although reliable systolic pressure measurements are possible with either tail-cuff or radiotelemetry techniques, in our hands some tail-cuff instruments fail to accurately detect elevated blood pressures. These data, however, do not distinguish whether this instrument-specific tail-cuff failure was due to operator or instrument inadequacies. We strongly advise investigators to obtain an independent and simultaneous validation of tail-cuff determinations of mouse blood pressure before making critical genotyping determinations.


Sign in / Sign up

Export Citation Format

Share Document