Soil-structure interaction at CDMG and USGS accelerograph stations

1989 ◽  
Vol 79 (1) ◽  
pp. 1-14
Author(s):  
C. B. Crouse ◽  
Behnam Hushmand

Abstract Forced harmonic and impulse-response vibration tests were conducted at several California accelerograph stations operated by the California Division of Mines and Geology (CDMG) and U.S. Geological Survey (USGS) to determine the extent to which soil-structure interaction may be affecting the recorded ground motions. The results of the tests on the foundations comprising USGS Station 6 in the Imperial Valley and CDMG Cholame 1E and Fault Zone 3 stations in the Cholame Valley indicated the presence of highly damped fundamental frequencies between 20 and 40 Hz. However, at the much larger Differential Array station, a masonry-block structure approximately 6 km southwest of Station 6, a moderately damped fundamental frequency of 12 Hz was observed. Approximate transfer functions between earthquake motions recorded at the stations and the free-field motions were computed from the response data obtained from the forced harmonic vibration tests. For the three smaller stations, these functions showed peak amplification factors ranging from 1.25 to 1.4 at frequencies between 20 and 40 Hz. The amplification at smaller frequencies was insignificant. For the Differential Array station, the amplification factor was 1.5 at 12 Hz and was roughly 0.6 for frequencies between 14 and 25 Hz. These results suggest that soil-structure interaction will have little effect on ground motions recorded at the smaller stations provided that most of the energy in these motions is confined to frequencies less than approximately 20 Hz. However, at the Differential Array station, soil-structure interaction probably has had, and will continue to have, a significant influence on the motions recorded at this station.

1979 ◽  
Vol 69 (1) ◽  
pp. 221-236
Author(s):  
R. R. Little ◽  
D. D. Raftopoulos

abstract An analytical expression describing the three-dimensional vertical soil-structure interaction effects is developed using Laplace and Hankel transformation techniques. Utilizing these transformation techniques and normal mode theory of vibration, an N-mass structural model is coupled to an elastic half-space representing the earth. The resulting interaction equation is solved by numerical iteration techniques for a model of a nuclear power plant subjected to actual earthquake ground excitation. The effects of the soil-structure interaction are evaluated by comparing free-field acceleration spectrum response curves with similar curves determined from the foundation motion. These effects are found to be significant for structures typical of modern nuclear power plants subjected to seismic ground motions.


2018 ◽  
Vol 2018 ◽  
pp. 1-17 ◽  
Author(s):  
Shahrokh Shahbazi ◽  
Iman Mansouri ◽  
Jong Wan Hu ◽  
Armin Karami

Seismic response of a structure is affected by its dynamic properties and soil flexibility does not have an impact on it when the bottom soil of foundation is supposedly frigid, and the soil flexibility is also ignored. Hence, utilizing the results obtained through fixed-base buildings can lead to having an insecure design. Being close to the source of an earthquake production causes the majority of earthquake’s energy to reach the structure as a long-period pulse. Therefore, near-field earthquakes produce many seismic needs so that they force the structure to dissipate output energy by relatively large displacements. Hence, in this paper, the seismic response of 5- and 8-story steel buildings equipped with special moment frames (SMFs) which have been designed based on type-II and III soils (according to the seismic code of Iran-Standard 2800) has been studied. The effects of soil-structure interaction and modeling of the panel zone were considered in all of the two structures. In order to model radiation damping and prevent the reflection of outward propagating dilatational and shear waves back into the model, the vertical and horizontal Lysmer–Kuhlemeyer dashpots as seen in the figures are adopted in the free-field boundary of soil. The selected near- and far-field records were used in the nonlinear time-history analysis, and structure response was compared in both states. The results obtained from the analysis showed that the values for the shear force, displacement, column axial force, and column moment force on type-III soil are greater than the corresponding values on type-II soil; however, it cannot be discussed for drift in general.


1978 ◽  
Vol 68 (3) ◽  
pp. 823-843
Author(s):  
G. N. Bycroft

abstract Rocking and vertical and horizontal translations of typical “free-field” seismometer installations lead to magnification of the ground motion record. This magnification can be significant for the higher frequency components if the terrain has a relatively low shear-wave velocity. Seismometers placed on foundations which cover a significant part of a wavelength of a horizontally incident wave, experience an attenuated ground motion. A method of correcting the seismograms for these effects is given. Compliance functions for a rigid sphere in a full elastic space are derived and are used to show that, in practical cases, down-hole seismometer installations are not significantly affected by interaction. These compliance functions should be useful in discussing the soil structure interaction of structures erected on bulbous piles. They may be also used as the basis of a method of determining elastic constants of ground at depth, in situ, and at different frequencies.