scholarly journals Corrigendum to "A comparative evaluation of design factors on bubble column operation in photosynthetic biogas upgrading" [Biofuel Res J 8(2) (2021) 1351-1373]

2021 ◽  
Vol 8 (4) ◽  
pp. 1550-1550
Author(s):  
Archishman Bose ◽  
Richard O’Shea ◽  
Richen Lin ◽  
Jerry D. Murphy
2021 ◽  
Vol 8 (2) ◽  
pp. 1351-1373
Author(s):  
Archishman Bose ◽  
Richard O’Shea ◽  
Richen Lin ◽  
Jerry D. Murphy

Studies attempting to optimise photosynthetic biogas upgrading by simultaneous investigation of the bubble column-photobioreactor setup have experienced considerable variability in results and conclusions. To identify the sources of such variation, this work quantitatively compared seven design factors (superficial gas velocity; liquid to gas flow rate (L/G) ratio; empty bed residence time; liquid inlet pH; liquid inlet alkalinity; temperature; and algal concentration) using the L16 Taguchi orthogonal array as a screening design of experiment. Assessments were performed using the signal to noise (S/N) ratio on the performance of CO2 removal (CO­2 removal efficiency, CO2 absorption rate, and overall CO2 mass transfer coefficient) and O2 stripping (O2 concentration in biomethane and O2 flow rate in biomethane). Results showed that pH and L/G ratio were the most critical design factors. Temperature and gas residence times had minimal impact on the biomethane composition. The interactive effect between pH and L/G ratio was the most impactful, followed by the interactive effects between superficial gas velocity and L/G ratio and pH on CO2 removal efficiency. The impact of L/G ratio, algal concentration, and pH (in that order of impact) caused up to a 90% variation in oxygen content in biomethane. However, algal concentration had a diminishing role as the L/G ratio increased. Using only the statistically significant main effects and interactions, the biomethane composition (CO2% and O2%) was predicted with over 95% confidence through regression equations for superficial gas velocity up to 0.2 cm/s.


1986 ◽  
Vol 51 (4) ◽  
pp. 362-369 ◽  
Author(s):  
Donna M. Risberg ◽  
Robyn M. Cox

A custom in-the-ear (ITE) hearing aid fitting was compared to two over-the-ear (OTE) hearing aid fittings for each of 9 subjects with mild to moderately severe hearing losses. Speech intelligibility via the three instruments was compared using the Speech Intelligibility Rating (SIR) test. The relationship between functional gain and coupler gain was compared for the ITE and the higher rated OTE instruments. The difference in input received at the microphone locations of the two types of hearing aids was measured for 10 different subjects and compared to the functional gain data. It was concluded that (a) for persons with mild to moderately severe hearing losses, appropriately adjusted custom ITE fittings typically yield speech intelligibility that is equal to the better OTE fitting identified in a comparative evaluation; and (b) gain prescriptions for ITE hearing aids should be adjusted to account for the high-frequency emphasis associated with in-the-concha microphone placement.


Sign in / Sign up

Export Citation Format

Share Document