scholarly journals A Perspective on Cell Tracking with Magnetic Particle Imaging

Tomography ◽  
2020 ◽  
Vol 6 (4) ◽  
pp. 315-324
Nano Letters ◽  
2017 ◽  
Vol 18 (1) ◽  
pp. 182-189 ◽  
Author(s):  
Guosheng Song ◽  
Min Chen ◽  
Yanrong Zhang ◽  
Liyang Cui ◽  
Haibo Qu ◽  
...  

2020 ◽  
Author(s):  
Kierstin P Melo ◽  
Ashley V Makela ◽  
Natasha N Knier ◽  
Amanda M Hamilton ◽  
Paula J Foster

AbstractIntroductionMagnetic particle imaging (MPI) is a new imaging modality that sensitively and specifically detects superparamagnetic iron oxide nanoparticles (SPIONs) within a sample. SPION-based MRI cell tracking has very high sensitivity, but low specificity and quantification of iron labeled cells is difficult. MPI cell tracking could overcome these challenges.MethodsMDM-AB-231BR cells labeled with MPIO, mice were intracardially injected with either 2.5 × 105 or 5.0 × 105 cells. MRI was performed in vivo the same day at 3T using a bSSFP sequence. After mice were imaged ex vivo with MPI. In a second experiment Mice received an intracardiac injection of either 2.5 × 10 5 or 5 × 10 4 MPIO-labeled 231BR cells. In a third experiment, mice were injected with 5 × 10 4 4T1BR cells, labelled with either MPIO or the SPION Vivotrax. MRI and MPI was performed in vivo.ResultsSignal from MPI and signal voids from MRI both showed more iron content in mice receiving an injection of 5.0 × 105 cells than the 2.5 × 105 injection. In the second experiment, Day 0 MRI showed signal voids and MPI signal was detected in all mouse brains. The MPI signal and iron content measured in the brains of mice that were injected with 2.5 × 10 5 cells were approximately four times greater than in brains injected with 5 × 10 4 cells. In the third experiment, in vivo MRI was able to detect signal voids in the brains of mice injected with Vivotrax and MPIO, although voids were fainter in Vivotrax labeled cells. In vivo MPI signal was only detectable in mice injected with MPIO-labeled cells.ConclusionThis is the first example of the use of MPIO for cell tracking with MPI. With an intracardiac cell injection, approximately 15% of the injected cells are expected to arrest in the brain vasculature. For our lowest cell injection of 5.0 × 104 cells this is ∼10000 cells.


2018 ◽  
Vol 45 ◽  
pp. 131-138 ◽  
Author(s):  
Xinyi Y Zhou ◽  
Zhi Wei Tay ◽  
Prashant Chandrasekharan ◽  
Elaine Y Yu ◽  
Daniel W Hensley ◽  
...  

Diagnostics ◽  
2020 ◽  
Vol 10 (10) ◽  
pp. 800
Author(s):  
Xiao Han ◽  
Yang Li ◽  
Weifeng Liu ◽  
Xiaojun Chen ◽  
Zeyu Song ◽  
...  

Magnetic particle imaging (MPI) is a cutting-edge imaging technique that is attracting increasing attention. This novel technique collects signals from superparamagnetic nanoparticles as its imaging tracer. It has characteristics such as linear quantitativity, positive contrast, unlimited penetration, no radiation, and no background signal from surrounding tissue. These characteristics enable various medical applications. In this paper, we first introduce the development and imaging principles of MPI. Then, we discuss the current major applications of MPI by dividing them into four categories: cell tracking, blood pool imaging, tumor imaging, and visualized magnetic hyperthermia. Even though research on MPI is still in its infancy, we hope this discussion will promote interest in the applications of MPI and encourage the design of tracers tailored for MPI.


2021 ◽  
Author(s):  
Ashley V Makela ◽  
Melissa A Schott ◽  
Olivia C Sehl ◽  
Julia J Gevaert ◽  
Paula J. Foster ◽  
...  

The use of imaging to detect and monitor the movement and accumulation of cells in living subjects can provide significant insights that can improve our understanding of metastasis and guide therapeutic development. For cell tracking using Magnetic Resonance Imaging (MRI), cells are labeled with iron oxides and the effects of the iron on water provides contrast. However, due to low specificity and difficulties in quantification with MRI, other modalities and approaches need to be developed. Magnetic Particle Imaging (MPI) is an emerging imaging technique which directly detects magnetic iron, allowing for a specific, quantitative and sensitive readout. Here, we use MPI to image iron-labeled tumor cells longitudinally, from implantation and growth at a primary site to movement to distant anatomic sites. In vivo bioluminescent imaging (BLI) was used to identify tumor metastases and computed tomography (CT) allowed for correlation of these signals to anatomic locations. These three imaging modalities provide information on immune escape and metastasis of iron-labeled, and unlabeled, tumor cells, and the accumulation of cell-free iron contrast over time. We identified iron signals by MPI and tumor cells via BLI, and correlated these positive contrast images with CT scans to reveal the anatomic sites with cancer cells; histologic analysis confirmed the presence of iron-labeled tumor cells in the tissues, suggesting that the metastatic cells retained enough iron for MPI detection. The use of multi-modality cell tracking reveals the movement, accumulation and fates of labeled cells that will be helpful understanding cancer progression and guiding the development targeted therapies.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Olivia C. Sehl ◽  
Paula J. Foster

AbstractMagnetic particle imaging (MPI) and fluorine-19 (19F) MRI produce images which allow for quantification of labeled cells. MPI is an emerging instrument for cell tracking, which is expected to have superior sensitivity compared to 19F MRI. Our objective is to assess the cellular sensitivity of MPI and 19F MRI for detection of mesenchymal stem cells (MSC) and breast cancer cells. Cells were labeled with ferucarbotran or perfluoropolyether, for imaging on a preclinical MPI system or 3 Tesla clinical MRI, respectively. Using the same imaging time, as few as 4000 MSC (76 ng iron) and 8000 breast cancer cells (74 ng iron) were reliably detected with MPI, and 256,000 MSC (9.01 × 1016 19F atoms) were detected with 19F MRI, with SNR > 5. MPI has the potential to be more sensitive than 19F MRI for cell tracking. In vivo sensitivity with MPI and 19F MRI was evaluated by imaging MSC that were administered by different routes. In vivo imaging revealed reduced sensitivity compared to ex vivo cell pellets of the same cell number. We attribute reduced MPI and 19F MRI cell detection in vivo to the effect of cell dispersion among other factors, which are described.


Sign in / Sign up

Export Citation Format

Share Document