scholarly journals INTRAOCULAR PRESSURE MEASUREMENT BY GOLDMANN APPLANATION TONOMETER AND NONCONTACT TONOMETERS TAKING CONSIDERATION OF CENTRAL CORNEAL THICKNESS- A COMPARATIVE CROSS-SECTIONAL STUDY

2017 ◽  
Vol 4 (83) ◽  
pp. 4880-4883
Author(s):  
Soumya Swarup Chattopadhyay ◽  
Soumyadeep Majumdar ◽  
Nitesh Singh

2020 ◽  
Vol 30 (6) ◽  
Author(s):  
Samuel Kyei ◽  
Frank Assiamah ◽  
Michael Agyemang Kwarteng ◽  
Cynthia Pakyennu Gboglu

BACKGROUND፡ The aim of this study was to determine whether Central Corneal Thickness (CCT) is associated with intraocular pressure measurement (IOP) with a Non-contact tonometer and the Goldmann applanation tonometer in glaucoma patients.MATERIALS AND METHODS: The study involved two hundred and thirty-two eyes of clinically diagnosed glaucoma patients receiving care at a referral facility. IOP measurements were obtained using both the Non-Contact Tonometer (NCT) and Goldmann Applanation Tonometer (GAT). The association between age, ethnicity, and CCT, as well as CCT on the measures of NCT and GAT, were analyzed.RESULTS: There were 64(55.2%) males and 52 (44.8%) females and their ages ranged from 18 to 85 years (mean age = 47.72; SD ±15.75 years). There was a weak positive correlation between the CCT and NCT findings in the right eye (r = 0.19, n = 116, p < 0.05) and in the left eye (r = 0.25, n = 116, p < 0.05). However, there was no correlation between CCT and GAT measurements. Age had a significant correlation with CCT while gender and ethnicity had no significant correlation.CONCLUSION: The study found a significant association between CCT and NCT. However, there was no significant association between CCT and GAT. CCT had an association with age but independent of gender and ethnicity since there was no significant relationship between these variables.



2019 ◽  
Vol 30 (2) ◽  
pp. 258-263 ◽  
Author(s):  
Barbara Cvenkel ◽  
Makedonka Atanasovska Velkovska ◽  
Vesna Dimovska Jordanova

Purpose: To evaluate and compare the accuracy of self-measurement of intraocular pressure using Icare Home rebound tonometer with Goldmann applanation tonometer and assess acceptability of self-tonometry in patients with glaucoma and ocular hypertension. Methods: In the study, 117 subjects were trained to use Icare Home for self-measurement. Icare Home tonometer readings were compared with Goldmann applanation tonometer, including one eye per patient. Agreement between the two methods of measurement was evaluated by Bland and Altmann analysis. Questionnaire was used to evaluate patients’ perception of self-tonometry. Results: One hundred and three out of 117 patients (88%) were able to measure their own intraocular pressure and 96 (82%) fulfilled the requirements for certification. The mean (SD) difference Goldmann applanation tonometer minus Icare Home was 1.2 (2.4) mmHg (95% limits of agreement, –3.4 to 5.9 mmHg). The magnitude of bias between the two methods depended on central corneal thickness, with greater bias at central corneal thickness <500 µm. In 65 out of 96 subjects (67.7%), Icare Home results were within 2 mmHg of the Goldmann applanation tonometer. Seventy-three out of 93 (78.5%) felt that self-tonometry was easy to use and 75 patients (80.6%) responded that they would use the device at home. Conclusion: Icare Home tonometry tends to slightly underestimate intraocular pressure compared to Goldmann applanation tonometer. Most patients were able to perform self-tonometry and found it acceptable for home use. Measurements using rebound self-tonometry could improve the quality of intraocular pressure data and optimize treatment regimen.



2020 ◽  
Author(s):  
Amr A. Gab-Alla

Abstract Background: To generate reference values of the central corneal thickness (CCT) with different refractive errors for the adult Egyptian population. Methods: A retrospective, observational, and cross-sectional study of 2200 eyes in 1166 subjects scheduled for LASIK, who came to private refractive eye center, Ismailia, Egypt. The study period was from January 2018 to January 2020. The subjects were divided into a broad range of myopia with spherical equivalent (SE) <-0.5D and hyperopia SE> +0.5D. Then, the myopic eyes divided into low (SE>-3.0D), moderate (SE-3.0D to >-6.0D), and high (SE<-6.0D). Similarly, the hyperopic eyes were divided into low (SE<+3.0 D) and moderate (SE+3.0D to <+6.0D) and high >+6.0D. The refractive error was measured by an auto-refractometer (Topcon, Tokyo Optical Co., Ltd., Japan), and CCT was measured using Sirius (CSO, Florence, Italy). Results: The data of 1100 myopic eyes in 556 subjects (30.5% males and 69.5% females) and 1100 hyperopic eyes in 610 subjects (33.6% males and 66.4% females). The mean+SD of CCT for the total myopic subjects was 531.98+32.92μm, range (406 to 636μm). The mean+SD of SE was -4.1±2.5D, range (-0.5 to -12.0D). The mean+SD of CCT for the total hyperopic subjects was 529±38.8μm, range (448 to 619 μm). The mean+SD of SE was +3.65+1.97D, range (+0.5 to +8.5D).Conclusion: In this study, the mean of CCT of the Egyptian population was 531.9 μm for myopic and 529μm for hyperopic subjects respectively. The myopic and hyperopic subjects show a reduction in CCT with age. Females have a thinner cornea than males, 23.6% of the myopic eyes, and 16.5% of the hyperopic eyes have CCT less than 500μm.