scholarly journals Magnetic Data Acquisition System (MAGDAS) Malaysia: Installation and Performance Analysis of Local Data Logger with Kyushu University Data Logger at USM Transkrian, Pulau Pinang

Author(s):  
Kharismi Burhanudin ◽  
Mohamad Huzaimy Jusoh ◽  
Zatul Iffah Abd Latiff ◽  
Siti Harwani Md Yusoff ◽  
Nurul Shazana Abd Hamid ◽  
...  
2021 ◽  
Vol 1768 (1) ◽  
pp. 012017
Author(s):  
K Burhanudin ◽  
M H Jusoh ◽  
Z I Abdul Latiff ◽  
M S Suaimi ◽  
Z Ibrahim ◽  
...  

2021 ◽  
Vol 67 (7) ◽  
pp. 2199-2206
Author(s):  
N.A. Zakaria ◽  
S.H.M. Yusoff ◽  
N.A.M. Rizal ◽  
N.S.A. Hamid ◽  
M.H. Hashim ◽  
...  

2018 ◽  
Vol 93 (5) ◽  
pp. 553-564 ◽  
Author(s):  
R. Umar ◽  
◽  
S. F. Natasha ◽  
S. S. N. Aminah ◽  
K. N. Juhari ◽  
...  

2020 ◽  
Vol 10 (24) ◽  
pp. 9092
Author(s):  
Edson L. Meyer ◽  
Oliver O. Apeh ◽  
Ochuko K. Overen

This paper centers on the design and installation of a robust photovoltaic (PV)-based microgrid data acquisition system (DAS) that can monitor different PV systems simultaneously. The PV-based microgrid consists of three solar systems: off-grid, hybrid and grid-assisted systems, each with 3.8 kWp located at SolarWatt park, Fort Hare Institute of Technology (FHIT), South Africa. The designed DAS is achieved by assembling and connecting a set of sensors to measure and log electrical and meteorological parameters from each of the three power plants. Meteorological parameters use a CR1000 datalogger while the electrical output parameters use a DT80 data logger. Calibration was done by voltage signal conditioning which helps to reduce errors initiated by analogue signals. The designed DAS mainly assist in assessing the potential of solar energy of the microgrid power plant considering the energy needed in the remote community. Besides, the simultaneous monitoring of the three systems ensures that the outdoor operating conditions are the same while comparing the logged data. A variable day and a week, data were used to verify the reliability of the system. The back of the array temperature was observed to be 42.7 °C when solar irradiance was 1246 W/m2. The ambient temperature and relative humidity were obtained at 21.3 °C and 63.3%, respectively. The PV current in all three systems increases with the solar irradiance and is highest around midday. The results obtained show that the designed DAS is of great interest in PV system developments.


Cryobiology ◽  
1982 ◽  
Vol 19 (6) ◽  
pp. 663
Author(s):  
M.D. Cosman ◽  
E.G. Cravalho ◽  
C.E. Huggins

2013 ◽  
Vol 774-776 ◽  
pp. 399-406
Author(s):  
Shan Hu Yu ◽  
You Lin Yao ◽  
Yu Jian Wang ◽  
Yun Hao Zhang ◽  
Jie Li ◽  
...  

According to the requirement of Formula Student China (FSC), combined with the actual of 2012 Guangzhou Auto S - Power team of South China University of Technology, a set of data acquisition system was designed and developed, and performance of the car chassis was analysed with data acquisition system, effective adjustment scheme is put forward. program was designed with LabVIEW software and NI cRIO 9076 data collector. This is experiment demonstrated that data acquisition system help designer to understand the quantitative value of the car performance in the process of the car testing, and help us to improve accuracy of the chassis adjustment, and also help us to improve work efficiency of commissioning phase.


Sign in / Sign up

Export Citation Format

Share Document