A differential method for locating single-phase-to-ground faults in isolated-neutral distribution grids

2019 ◽  
Vol 6 ◽  
pp. 42-44
Author(s):  
Elena Kirzhatskikh ◽  
Vladimir Kozlov
Author(s):  
A. I. Fedotov ◽  
L. V. Akhmetvaleeva ◽  
R. S. Basyrov ◽  
G. V. Vagapov ◽  
E. A. Fedotov

The aim of the paper is theoretical and experimental research of processes during the single-phase ground faults in electrical distribution grids of 10/06/35 kV with isolated neutral mode. The mathematical method of rationing is used for the analysis of the spectral composition of currents and voltages increasing the information content of the allocated higher harmonics of current and voltage. The paper show a comparison of the results of spectral analysis with and without taking into account the mathematical rationing obtained on the simulation model. Field experiments have demonstrated the effectiveness of using of the method of mathematical rationing of the higher harmonic components of current and voltage for various types of single-phase ground faults. The results of field experiments provided an opportunity of improving the methodology of yearling detection of single-phase ground faults in electric grids of 6-10-35 kV with an isolated mode of neutral. The conclusion of the research is the possibility of a significantly more accurate selection of the resonant frequencies of the spectrum of currents and voltages obtained by using of the method of mathematical rationing. The possibility of earlier and more precise localization of the feeder with ground fault is shown on the base more precise selection of the resonant frequency currents and voltages.


2021 ◽  
Vol 7 (2) ◽  
pp. 111-116
Author(s):  
Zinoviy Bakhor ◽  
◽  
Andriy Yatseiko ◽  
Roman Ferensovych

The arc overvoltages during the single phase to earth faults in electrical distribution grids of 6-35 kV are the object of the research in this paper. The development of 35 kV distribution electrical grids is accompanied by the construction of new overhead and cable power lines. It causes a change of the capacitive earth fault current in the grids and also affects the multiplicity of overvoltages in electrical distribution grids during the single phase to earth faults. The paper shows the research results of overvoltages during arc single phase to earth faults in 35 kV electrical grid with the different grounding modes of a grid neutral (an isolated neutral, a grounded neutral through an arc-quenching reactor, a grounded neutral through a resistor). The calculations were performed on the digital models of the investigation power grids. According to the research results, a mathematical model has been created, which allows obtaining the maximum expected multiplicity of overvoltages in 35 kV electrical grids during the single phase to earth faults. This allows making decisions about the optimal measures for the protection of an electrical equipment insulation taking into account expected values of overvoltages as early as at the stage of pre-design works for the development of such electrical grids.


2020 ◽  
Vol 11 (1) ◽  
pp. 774-785 ◽  
Author(s):  
Xuewen Wang ◽  
Hengxu Zhang ◽  
Fang Shi ◽  
Qiuwei Wu ◽  
Vladimir Terzija ◽  
...  

2018 ◽  
Vol 2018 (5) ◽  
pp. 96-99
Author(s):  
V.M. Bezruchko ◽  
◽  
R.O. Buinyi ◽  
A.Y. Strogii ◽  
V.I. Tkach ◽  
...  