HLA-D and T Lymphocyte Reactivity to Specific Periodontal Pathogens in Type 1 Diabetic Periodontitis

1993 ◽  
Vol 64 (10) ◽  
pp. 974-979 ◽  
Author(s):  
Catherine Seagren Alley ◽  
Richard A. Reinhardt ◽  
Connie A. Maze ◽  
Linda M. DuBois ◽  
Timothy O. Wahl ◽  
...  
2005 ◽  
Vol 12 (12) ◽  
pp. 1416-1424 ◽  
Author(s):  
Kovit Pattanapanyasat ◽  
Surada Lerdwana ◽  
Egarit Noulsri ◽  
Thanyanan Chaowanachan ◽  
Punneeporn Wasinrapee ◽  
...  

ABSTRACT Use of the standard dual-platform flow cytometric method for determination of CD4+ T-lymphocyte counts, which needs both a flow cytometer (FCM) and hematological analyzer, would inevitably lead to increased variability. The development of new single-platform (SP) FCMs that provide direct CD4+ T-lymphocyte counts for improved assay precision and accuracy have recently attracted attention. This study evaluated one of those systems, CyFlowgreen (Partec), a single-parameter SP volumetric FCM. The performance of CyFlowgreen was compared with those of two reference standard SP microbead-based technologies of the three-color TruCOUNT tube with the FACScan FCM and a two-color FACSCount system (Becton Dickinson Biosciences). Absolute CD4+ and CD8+ T-lymphocyte counts in 200 human immunodeficiency virus type 1-seropositive blood specimens were determined. Statistical analysis for correlation and agreement were performed. A high correlation of absolute CD4 counts was shown when those obtained with CyFlowgreen were compared with those obtained with the bead-based three-color TruCOUNT system (R 2 = 0.96; mean bias, −69.1 cells/μl; 95% confidence interval [CI], −225.7 to +87.5 cells/μl) and the FACSCount system (R 2 = 0.97; mean bias, −40.0 cells/μl; 95% CI, −165.1 to +85.1 cells/μl). The correlation of the CD4+ T-lymphocyte counts obtained by the two bead-based systems was high (R 2 = 0.98). Interestingly, CyFlowgreen yielded CD4+ T-lymphocyte counts that were 21.8 and 7.2 cells/μl lower than those obtained with the TruCOUNT and the FACSCount systems, respectively, when CD4+ T-lymphocyte counts were <250 CD4+ T-lymphocyte counts/μl range or 17.3 and 5.8 cells/μl less, respectively, when CD4+ T-lymphocyte counts were <200 cells/μl. The single-parameter CyFlowgreen volumetric technology performed well in comparison with the performance of the standard SP bead-based FCM system. However, a multicenter comparative study is needed before this FCM machine is implemented in resource-limited settings.


1999 ◽  
pp. 272-278 ◽  
Author(s):  
F Dotta ◽  
S Dionisi ◽  
V Viglietta ◽  
C Tiberti ◽  
MC Matteoli ◽  
...  

The target molecules of the T-cell response in type 1 diabetes, despite their pathogenic importance, remain largely uncharacterized, especially in humans. Interestingly, molecules such as insulin and glutamic acid decarboxylase (GAD) have been shown to be a target not only of autoantibodies, but also of autoreactive T-lymphocytes both in man and in the non-obese diabetic (NOD) mouse. In the present study we aimed to determine the existence of a specific T-cell response towards the insulinoma-associated protein 2 (IA-2) islet tyrosine phosphatase, a recently identified autoantigen which is the target of autoantibodies strongly associated with diabetes development. Human recombinant IA-2 produced in Escherichia coli, was tested for its reactivity with peripheral blood lymphocytes obtained from 16 newly diagnosed type 1 diabetic patients and from 25 normal controls, 15 of whom were HLA-DR-matched. A T-cell proliferation assay was performed in triplicate employing freshly isolated cells in the absence or in the presence of the antigen to be tested (at two different concentrations: 2 microg/ml and 10 microg/ml). A specific T-cell proliferation (defined as a stimulation index (S.I.) >/=3) was observed against IA-2 used at a concentration of 10 microg/ml (but not of 2 microg/ml) in 8/16 diabetic patients, in 1/15 HLA-DR-matched control subjects (P<0.01 by Fisher exact test) and in 0/10 of the remaining normal individuals. A statistically significant difference (P<0.003 by Mann-Whitney U test) was also observed in S.I. values between patients (3.1+/-1.4) and HLA-DR-matched controls (1.7+/-0.54) employing IA-2 at a concentration of 10 microg/ml. However, when IA-2 was used at a concentration of 2 microg/ml, the difference in S. I. between patients (1.65+/-0.8) and controls (1.0+/-0.3) did not reach statistical significance. In conclusion, these data show the presence of a specific, dose-dependent T-lymphocyte response against the IA-2 islet tyrosine phosphatase at the onset of type 1 diabetes. Consequently, this molecule appears to be a target not only at the B-lymphocyte but also at the T-lymphocyte level, reinforcing the potential pathogenic role of this autoantigen in the islet destructive process.


2005 ◽  
Vol 21 (8) ◽  
pp. 719-727 ◽  
Author(s):  
Florence Buseyne ◽  
Jérôme Le Chenadec ◽  
Marianne Burgard ◽  
Nassima Bellal ◽  
Marie-Jeanne Mayaux ◽  
...  

1997 ◽  
Vol 13 (1) ◽  
pp. 33-39 ◽  
Author(s):  
MARC DUPUIS ◽  
MADHUSUDAN V. PESHWA ◽  
CLAUDIA BENIKE ◽  
SMRITI K. KUNDU ◽  
EDGAR G. ENGLEMAN ◽  
...  

2011 ◽  
Vol 129 (5) ◽  
pp. 1126-1136 ◽  
Author(s):  
Masaaki Toda ◽  
Linan Wang ◽  
Suguru Ogura ◽  
Mie Torii ◽  
Makoto Kurachi ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document