scholarly journals Evaluation of soft-plaque stenoses in coronary artery stents using conventional and monoenergetic images: first in-vitro experience and comparison of two different dual-energy techniques

2020 ◽  
Vol 10 (3) ◽  
pp. 612-623
Author(s):  
Tilman Hickethier ◽  
Justus Wenning ◽  
Grischa Bratke ◽  
David Maintz ◽  
Guido Michels ◽  
...  
2017 ◽  
Vol 11 (1) ◽  
pp. 33-39 ◽  
Author(s):  
Tilman Hickethier ◽  
Bettina Baeßler ◽  
Jan Robert Kroeger ◽  
Jonas Doerner ◽  
Gregor Pahn ◽  
...  

2011 ◽  
Vol 80 (1) ◽  
pp. 143-150 ◽  
Author(s):  
Henning Steen ◽  
Florian André ◽  
Grigorios Korosoglou ◽  
Dirk Mueller ◽  
Waldemar Hosch ◽  
...  

2020 ◽  
Vol 36 (6) ◽  
pp. 1021-1029
Author(s):  
Leonardo Cecchetti ◽  
Tianshi Wang ◽  
Ayla Hoogendoorn ◽  
Karen T. Witberg ◽  
Jurgen M. R. Ligthart ◽  
...  

2010 ◽  
Vol 74 (1) ◽  
pp. 156-160 ◽  
Author(s):  
Abdulrahman Marzouq Almutairi ◽  
Zhonghua Sun ◽  
Curtise Ng ◽  
Zakariya A. Al-Safran ◽  
Abeer A. Al-Mulla ◽  
...  

1995 ◽  
Vol 28 (1) ◽  
pp. 17-26 ◽  
Author(s):  
Jon Peacock ◽  
Shelly Hankins ◽  
Travis Jones ◽  
Robert Lutz

2003 ◽  
Vol 13 (4) ◽  
pp. 830-835 ◽  
Author(s):  
David Maintz ◽  
Kai-Uwe Juergens ◽  
Thomas Wichter ◽  
Matthias Grude ◽  
Walter Heindel ◽  
...  

2019 ◽  
Vol 92 (1104) ◽  
pp. 20190530 ◽  
Author(s):  
Ross Edward Taylor ◽  
Pamela Mager ◽  
Nam C. Yu ◽  
David P. Katz ◽  
Jett R. Brady ◽  
...  

Objectives: To estimate the minimum detectable iodine concentration on multiple dual-energy CT (DECT) platforms. Methods and materials: A phantom containing iodine concentrations ranging from 0 to 10 mg ml−1 was scanned with five dual-energy platforms (two rapid kilo volt switching (r-kVs), one dual source (DS), one sequential acquisition and one split-filter). Serial dilutions of 300 mg ml−1 iodinated contrast material were used to generate concentrations below 2 mg ml−1. Iodine density and virtual monoenergetic images were reviewed by three radiologists to determine the minimum visually detectable iodine concentration. Contrast-to-noise ratios (CNRs) were calculated. Results: 1 mg mL−1 (~0.8 mg mL−1 corrected) was the minimum visually detectable concentration among the platforms and could be seen by all readers on the third-generation r-kVs and DS platforms. Conclusions: At low concentrations, CNR for monoenergetic images was highest on the DS platform and lowest in the sequential acquisition and split-filter platforms. Advances in knowledge: The results of this study corroborate previous in vivo estimates of iodine detection limits at DECT and provide a comparison for the performance of different DECT platforms at low iodine concentrations in vitro.


Sign in / Sign up

Export Citation Format

Share Document