scholarly journals The dosimetric comparison using anisotropic analytical algorithm (AAA) and Acuros XB algorithms in the target overlapping with air cavity of pituitary carcinoma

2021 ◽  
Vol 0 ◽  
pp. 0-0
Author(s):  
Isra Israngkul-Na-Ayuthaya ◽  
Sivalee Suriyapee ◽  
Taweap Sanghamthum
2018 ◽  
Vol 18 (1) ◽  
pp. 75-81 ◽  
Author(s):  
Ashfaq Zaman ◽  
Muhammad Basim Kakakhel ◽  
Amjad Hussain

AbstractBackgroundA comparison of anisotropic analytical algorithm (AAA) and Acuros XB (AXB) dose calculation algorithms with Electron Gamma Shower (EGSnrc) Monte Carlo (MC) for modelling lung and bone heterogeneities encountered during enhanced dynamic wedged (EDWs) radiotherapy dose deliveries was carried out.Materials and methodsIn three heterogenous slab phantoms: water–bone, lung–bone and bone–lung, wedged percentage depth doses with EGSnrc, AAA and AXB algorithms for 6 MV photons for various field sizes (5×5, 10×10 and 20×20 cm2) and EDW angles (15°, 30°, 45° and 60°) have been scored.ResultsFor all the scenarios, AAA and AXB results were within ±1% of the MC in the pre-inhomogeneity region. For water–bone AAA and AXB deviated by 6 and 1%, respectively. For lung–bone an underestimation in lung (AAA: 5%, AXB: 2%) and overestimation in bone was observed (AAA: 13%, AXB: 4%). For bone–lung phantom overestimation in bone (AAA: 7%, AXB: 1%), a lung underdosage (AAA: 8%, AXB: 5%) was found. Post bone up to 12% difference in the AAA and MC results was observed as opposed to 6% in case of AXB.ConclusionThis study demonstrated the limitation of the AAA (in certain scenarios) and accuracy of AXB for dose estimation inside and around lung and bone inhomogeneities. The dose perturbation effects were found to be slightly dependent on the field size with no obvious EDW dependence.


2021 ◽  
pp. 1-13
Author(s):  
Chaymaa Abdullah ◽  
Hamed Farag ◽  
Wael El-Sheshtawy ◽  
Hassan Aboelenein ◽  
O.W. Guirguis

OBJECTIVE: To evaluate dose differences predicted between using Anisotropic Analytical Algorithm (AAA) and Acuros XB (AXB) in patients diagnosed with locally advanced non-small cell lung cancer (NSCLC) treated with intensity modulated radiation therapy (IMRT). METHODS: A phantom study was done to evaluate the dose prediction accuracy of AXB and AAA beyond low-density medium by comparing the calculated measurement results. Thirty-two advanced NSCLC patients were subjected to IMRT. The dose regimen was 60 Gy over 30 fractions. Effects on planning target volume (PTV) and organ-at-risk (OAR) were evaluated. Clinically acceptable treatment plans with AAA were re-calculated using AXB algorithms with two modes Dw and Dm at the same beam arrangements and multileaf collimator leaf settings as with AAA. RESULTS: Using AXB yielded better agreement with the measurements and the average dose difference for all points was about 0.5%. Conversely, using AAA showed a larger disagreement with measured values and the average difference was up to 5.9%. The maximum relative difference was between AXB_Dm and AAA for PTV dose (D98 %). The percentage dose differences of plans calculated by AAA, AXB_Dw and AAA, AXB_Dm revealed that AAA overestimated the dose than AXB. Regarding OAR, results showed significant difference for lungs-PTV. CONCLUSIONS: AXB algorithm yields more accurate dose prediction than AAA in heterogeneous medium. Differences in dose distribution are observed when plans re-calculated with AXB indicating that AAA apparently overestimates dose, particularly the PTV dose. Thus, AXB algorithm should be used in preference to AAA for cases in which PTVs are involved with tissues of highly different densities, such as lung.


2015 ◽  
Vol 42 (6Part13) ◽  
pp. 3359-3359
Author(s):  
D Mynampati ◽  
H Kuo ◽  
R Yaparpalvi ◽  
P Godoy Scripes ◽  
W Tome

PLoS ONE ◽  
2018 ◽  
Vol 13 (11) ◽  
pp. e0207232 ◽  
Author(s):  
Kyeong-Hyeon Kim ◽  
Jin-Beom Chung ◽  
Tae Suk Suh ◽  
Sang-Won Kang ◽  
Seong-Hee Kang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document