scholarly journals Temperature-Responsive Chromatography Using Poly-(N-isopropylacrylamide) Hydrogel-Modified Silica.

2002 ◽  
Vol 18 (1) ◽  
pp. 45-48 ◽  
Author(s):  
Hideko KANAZAWA ◽  
Tatsuo SUNAMOTO ◽  
Eri AYANO ◽  
Yoshikazu MATSUSHIMA ◽  
Akihiko KIKUCHI ◽  
...  
2019 ◽  
Vol 178 ◽  
pp. 253-262 ◽  
Author(s):  
Kenichi Nagase ◽  
Daimu Inanaga ◽  
Daiju Ichikawa ◽  
Aya Mizutani Akimoto ◽  
Yutaka Hattori ◽  
...  

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Kenichi Nagase ◽  
Teruno Nishiyama ◽  
Masakazu Inoue ◽  
Hideko Kanazawa

AbstractTherapeutic drug monitoring is a key technology for effective pharmacological treatment. In the present study, a temperature-responsive chromatography column was developed for safe and simple therapeutic drug monitoring without the use of organic solvents. Poly(N-isopropylacrylamide) (PNIPAAm) hydrogel-modified silica beads were prepared via a condensation reaction and radical polymerization. The temperature-dependent elution behavior of the drugs was observed using a PNIPAAm-modified silica-bead packed column and an all-aqueous mobile phase. Sharp peaks with reproducible retention times were observed at temperatures of 30 °C or 40 °C because the PNIPAAm hydrogel on the silica beads shrinks at these temperatures, limiting drug diffusion into the PNIPAAm hydrogel layer. The elution behavior of the sample from the prepared column was examined using a mixture of serum and model drugs. The serum and drugs were separated on the column at 30 °C or 40 °C, and the concentration of the eluted drug was obtained using the calibration curve. The results show that the prepared chromatography column would be useful for therapeutic drug monitoring because the drug concentration in serum can be measured without using organic solvents in the mobile phase and without any need for sample preparation.


The Analyst ◽  
2016 ◽  
Vol 141 (3) ◽  
pp. 910-917 ◽  
Author(s):  
Yuki Hiruta ◽  
Ryosuke Kanazashi ◽  
Eri Ayano ◽  
Teruo Okano ◽  
Hideko Kanazawa

The separation system with dual temperature-response and molecular recognition characteristics leads to selective separation using only aqueous solution.


1996 ◽  
Vol 68 (1) ◽  
pp. 100-105 ◽  
Author(s):  
Hideko Kanazawa ◽  
Kazuo Yamamoto ◽  
Yoshikazu Matsushima ◽  
Nobuharu Takai ◽  
Akihiko Kikuchi ◽  
...  

1997 ◽  
Vol 69 (5) ◽  
pp. 823-830 ◽  
Author(s):  
Hideko Kanazawa ◽  
Yuki Kashiwase ◽  
Kazuo Yamamoto ◽  
Yoshikazu Matsushima ◽  
Akihiko Kikuchi ◽  
...  

2018 ◽  
Vol 1568 ◽  
pp. 38-48 ◽  
Author(s):  
Kohei Okubo ◽  
Koji Ikeda ◽  
Ayaka Oaku ◽  
Yuki Hiruta ◽  
Kenichi Nagase ◽  
...  

2016 ◽  
Author(s):  
Arjen Gebraad ◽  
Teuvo Hentunen ◽  
Tiina Laitala-Leinonen

2000 ◽  
Vol 116 (1) ◽  
pp. 56-61
Author(s):  
Tatsuo YAMAGUCHI ◽  
Toshiaki NAKAI ◽  
Kunihiko TAKEDA

2013 ◽  
Vol 31 (5) ◽  
pp. 423
Author(s):  
Chao FAN ◽  
Zifeng SONG ◽  
Weijie QIN ◽  
Yun CAI ◽  
Xiaohong QIAN

Sign in / Sign up

Export Citation Format

Share Document