scholarly journals Determination of traces of chlorine in aluminum by the anion exchange-photometric method

1972 ◽  
Vol 21 (4) ◽  
pp. 480-486 ◽  
Author(s):  
Tsutomu FUKASAWA ◽  
Kazuhiko KATAGIRI
1965 ◽  
Vol 48 (6) ◽  
pp. 1095-1100
Author(s):  
James P Ussary ◽  
Charles W Gehrke

Abstract Three primary standard grade potassium salts, eight Magruder check samples, and 18 commercial fertilizer samples were analyzed by three methods. Primary standards gave an average recovery of 100.0% and an average range of 0.21% K20. Magruder check samples averaged 0.09% K20 higher by the modified flame photometric method than the grand averages of the STPB results on the respective Magruder reports. The modified flame photometric method averaged 0.02% K20 lower than the official flame photometric method and 0.11% K20 higher than the official STPB method on 18 commercial fertilizer samples. The automatic flame photometric method, without anion exchange cleanup, is rapid enough for routine analysis and is as accurate and precise as the AOAC official methods. The method was also applied to the direct available P205 extract. Results on three primary grade potassium salts, seven Magruder check samples, and 13 commercial fertilizer samples were as accurate and precise as the official STPB method.


Author(s):  
Abbas Shebeeb Al-kadumi ◽  
Sahar Rihan Fadhel ◽  
Mohammed Abdullah Ahmed ◽  
Luma Amer Musa

We proposed two simple, rapid, and convenient spectrophotometric methods are described for the determination of Amoxicillin in bulk and its pharmaceutical preparations. They are based on the measurement of the flame atomic emission of potassium ion (in first method) and colorimetric determination of the green colored solution for manganite ion at 610 nm formed after reaction of Amoxicillin with potassium permanganate as oxidant agent (in the second method) in basic medium. The working conditions of the methods were investigated and optimized. Beer's law plot showed a good correlation in the concentration range of 5-45 μg/ml. The detection limits and relative standared deviations were (2.573, 2.814 μg/ml) (2.137, 2.498) for the flame emission photometric method and (1.844, 2.016 μg/ml) (1.645,1.932) for colorimetric methods for capsules and suspensions respectively. The methods were successfully applied to the determination of Amoxicillin in capsules and suspensions, and the obtained results were in good agreement with the label claim. No interference was observed from the commonly encountered additives and expectancies.


Sign in / Sign up

Export Citation Format

Share Document