scholarly journals The"slide technique"-a novel free-hand method of subaxial cervical pedicle screw placement

2020 ◽  
Author(s):  
Bin Liu ◽  
Xiangyang Liu ◽  
Xiongjie Shen ◽  
Guoping Wang ◽  
Yixin Chen

Abstract Background: Cervical Pedicle Screw(CPS) placement is a challenging work due to the high risk of neurovascular complications. Although there have been several different free-hand or navigation assisted techniques for CPS placement, perforations may occur during screw insertion, especially lateral perforation. The objective of this manuscript is to describe a novel free-hand technique for subaxial CPS placement (C3–C7) and to evaluate if it decreases the chances of perforation.Methods: Thirty-two patients undergoing surgery with CPS instrumentation (C3–C7) at our institute between June 2017 and December 2018 were included in this study. All the patients had cervical trauma, and pedicle screw insertion was performed according to the free-hand “slide technique”. The lamina, lateral mass and facet joint of the target area were exposed and the optimal entry point was found on the lateral mass posterior surface. A pedicular probe was then inserted and gently advanced. During the pedicle probe insertion, the cortex of the medial margin of the pedicle acted as a slide to permit the safe insertion of the screw. If the pedicle screw pathway was intact, the screw of the appropriate size was carefully placed. Three-dimensional (3D) CT imaging reconstruction was performed in all the patients after surgery, and screw perforations were graded with the Gertzbein-Robbins classification.Results: A total of 257 CPSs (C3-7) were inserted, of which 41 CPSs were in C3, 61 CPSs were in C4, 55 CPSs were in C5, 53 CPSs were in C6, and 47 CPSs were in C7. The diameter and length of CPSs were 3.5 mm and 22-26 mm respectively. According to the Gertzbein-Robbins classification, grade 0, 231 screws; grade 1, 19 screws; and grade 2, 7 screws. No neurovascular complications occurred stemming from malpositioning of pedicle screws. Among perforated screws (26 screws), there were 16 lateral perforations, 5 medical perforations, and 4 inferior perforations.Conclusions: The initial usage result shows the “slide technique” is a safe, effective and cost-effective technique for pedicle screw placement in the cervical spine. This is the first report of such a technique. We recommend its use though further studies are needed.

2019 ◽  
Author(s):  
Bin Liu ◽  
Xiangyang Liu ◽  
Xiongjie Shen ◽  
Guoping Wang ◽  
Yixin Chen

Abstract Background : Cervical Pedicle Screw(CPS) placement is a challenging work due to high risk of neurovascular complications. Although there have been a number of different free-hand or navigation assisted techniques for CPS placement, perforations always occur during screw insertion, especially lateral perforation. The objective of this research is to describe a novel free-hand technique for subaxial CPS placement (C3–C7) for improving security and decreasing the chances of perforation. Methods : Thirty-two patients undergoing surgery with CPS instrumentation (C3–C7) at our institute between June 2017 and December 2018 were included in the study. All the patients had cervical trauma, and pedicle screw insertion was made according to the free-hand “slide technique”. Lamina, lateral mass and facet joint of the target area were clearly exposed and the optimal entry point was found on the lateral mass posterior surface. A pedicular probe was then inserted and gently advanced. During the pedicle probe insertion, the cortex of the medial margin of the pedicle acted as a “slide” to permit safe insertion of the screw. If the pedicle screw pathway was intact, screw of appropriate size was carefully placed. Three-dimensional (3D) CT imaging reconstruction was performed in all the patients after surgery, and screw perforations were graded with the Gertzbein-Robbins classification. Results : A total of 257 CPSs (C3-7) were inserted, of which 41 CPSs in C3, 61 CPSs in C4, 55 CPSs in C5, 53 CPSs in C6, and 47 CPSs in C7. The diameter and length of CPSs were 3.5 mm and 22-26 mm respectively. According to the Gertzbein-Robbins classification, grade 0, 231 screws; grade 1, 19 screws; and grade 2, 7 screws. No neurovascular complications occurred stemming from malpositioning of pedicle screws. In perforated screws (26 screws), lateral perforations were 16, medical perforations were 5, and inferior perforations were 4. Conclusions : The initial usage result show the “slide technique” is a safe, effective and cost-effective technique for pedicle screw placement in the cervical spine. This is the first report of such technique, we recommend it to wide practical application though further studies are needed.


2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
S. Harrison Farber ◽  
Jakub Godzik ◽  
Randall J. Hlubek ◽  
James J. Zhou ◽  
Corey T. Walker ◽  
...  

2017 ◽  
Vol 14 (3) ◽  
pp. 84-88 ◽  
Author(s):  
Jung Hwan Lee ◽  
Byung Kwan Choi ◽  
In Ho Han ◽  
Won Gyu Choi ◽  
Kyoung Hyup Nam ◽  
...  

2018 ◽  
Vol 17 (1) ◽  
pp. 52-60 ◽  
Author(s):  
Zhimin Pan ◽  
Junlong Zhong ◽  
Shiming Xie ◽  
Limin Yu ◽  
Chunyang Wu ◽  
...  

2019 ◽  
Vol 126 ◽  
pp. e803-e813 ◽  
Author(s):  
Manuel Moser ◽  
Mazda Farshad ◽  
Nadja A. Farshad-Amacker ◽  
Michael Betz ◽  
José Miguel Spirig

2010 ◽  
Vol 13 (4) ◽  
pp. 509-515 ◽  
Author(s):  
Cary Idler ◽  
Kevin W. Rolfe ◽  
Josef E. Gorek

Object This study was conducted to assess the in vivo safety and accuracy of percutaneous lumbar pedicle screw placement using the owl's-eye view of the pedicle axis and a new guidance technology system that facilitates orientation of the C-arm into the appropriate fluoroscopic view and the pedicle cannulation tool in the corresponding trajectory. Methods A total of 326 percutaneous pedicle screws were placed from L-3 to S-1 in 85 consecutive adult patients. Placement was performed using simple coaxial imaging of the pedicle with the owl's-eye fluoroscopic view. NeuroVision, a new guidance system using accelerometer technology, helped align the C-arm trajectory into the owl's-eye view and the cannulation tool in the same trajectory. Postoperative fine-cut CT scans were acquired to assess screw position. Medical records were reviewed for complications. Results Five of 326 screws breached a pedicle cortex—all breaches were less than 2 mm—for an accuracy rate of 98.47%. Five screws violated an adjacent facet joint. All were at the S-1 superior facet and included in a fusion. No screw violated an adjacent mobile facet or disc space. There were no cases of new or worsening neurological symptoms or deficits for an overall clinical accuracy of 100%. Conclusions The owl's-eye technique of coaxial pedicle imaging with the C-arm fluoroscopy, facilitated by NeuroVision, is a safe and accurate means by which to place percutaneous pedicle screws for degenerative conditions of the lumbar spine. This is the largest series reported to use the oblique or owl's-eye projection for percutaneous pedicle screw insertion. The accuracy of percutaneous screw insertion with this technique meets or exceeds that of other reported clinical series or techniques.


Sign in / Sign up

Export Citation Format

Share Document