scholarly journals Influence of automated visual field testing on intraocular pressure

2020 ◽  
Author(s):  
Samuel Bertaud ◽  
Elisabeth Skarbek Borowski ◽  
Rachid Abbas ◽  
Christophe Baudouin ◽  
Antoine Labbé

Abstract Background To evaluate the influence of automated visual field (VF) testing on intraocular pressure (IOP) in patients with ocular hypertension (OHT) or glaucoma. Methods We conducted a prospective observational study from October 2015 to July 2016 at Quinze-Vingts National Ophthalmology Hospital in Paris. Ninety-five right eyes of 95 patients followed for glaucoma or OHT with reliable standard automated perimetry (SAP) were included. IOP was measured three times using a Nidek NT-510 non-contact tonometer within a maximum of 5 minutes before and after VF testing. Subanalyses using logistic regression analysis were performed to evaluate the impact of gender, age, central corneal thickness (CCT), mean deviation (MD) of the VF, VF test duration and filtration surgery on IOP fluctuations. Results There was no significant change in IOP after VF testing, with IOP’s 15.14 ± 4.00 mmHg before and 14.98 ± 3.33 mmHg after the VF (P = 0.4). The average change in IOP was 0.15 ± 1.82 mmHg. Using multivariate analysis, no effect of the VF test on IOP was found (global model fit R²=0.12), whether based on duration of the VF test (P = 0.18) or the MD (P = 0.7) after adjustment for age, gender, CCT and history of glaucoma surgery. Similarly, there was no significant difference within different types of glaucoma, including open-angle glaucoma (p = 0.36), chronic angle closure glaucoma (P = 0.85) and OHT (P = 0.42). The subgroup of patients with an IOP elevation > 2 mmHg had a significantly higher SAP test duration (P = 0.002). Conclusion VF testing by SAP does not influence IOP as measured with a non-contact tonometer.

2020 ◽  
Author(s):  
S Bertaud ◽  
E Skarbek Borowski ◽  
R Abbas ◽  
C Baudouin ◽  
A Labbé

Abstract Background: To evaluate the influence of automated visual field (VF) testing on intraocular pressure (IOP) in patients with ocular hypertension (OHT) or glaucoma.Methods: We conducted a prospective observational study in the glaucoma department at Quinze-Vingts National Ophthalmology Hospital in Paris. Ninety-five right eyes of 95 patients followed for glaucoma or OHT were included. IOP was measured three times using a Nidek NT-510 non-contact tonometer within a maximum of 5 minutes before and after VF testing. Sub analyses using logistic regression analysis were performed to evaluate the impact of gender, age, central corneal thickness (CCT), mean deviation (MD) of the VF, VF test duration and filtration surgery on IOP fluctuations.Results: There was no significant change in IOP after VF testing, with IOP’s 15.14 ± 4.00 mmHg before and 14.98 ± 3.33 mmHg after the VF (P = 0.4). The average change in IOP was 0.15 ± 1.82 mmHg. Using multivariate analysis, no effect of the VF test on IOP was found (global model fit R²=0.12), whether based on duration of the VF test (P=0.18) or the MD (P=0.7) after adjustment for age, gender, CCT and history of glaucoma surgery. Similarly, there was no significant difference within different types of glaucoma, including open-angle glaucoma (P=0.36), chronic angle closure glaucoma (P=0.85) and OHT (P=0.42). The subgroup of patients with an IOP elevation ≥ 2mmHg had a significantly higher VF test duration (P=0.002).Conclusion: VF testing does not influence IOP as measured with a non-contact tonometer.


2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Samuel Bertaud ◽  
Elisabeth Skarbek Borowski ◽  
Rachid Abbas ◽  
Christophe Baudouin ◽  
Antoine Labbé

Abstract Background To evaluate the influence of automated visual field (VF) testing on intraocular pressure (IOP) in patients with ocular hypertension (OHT) or glaucoma. Methods We conducted a prospective observational study in the glaucoma department at Quinze-Vingts National Ophthalmology Hospital in Paris. Ninety-five right eyes of 95 patients followed for glaucoma or OHT were included. IOP was measured three times using a Nidek NT-510 non-contact tonometer within a maximum of 5 min before and after VF testing. Sub analyses using logistic regression analysis were performed to evaluate the impact of gender, age, central corneal thickness (CCT), mean deviation (MD) of the VF, VF test duration and filtration surgery on IOP fluctuations. Results There was no significant change in IOP after VF testing, with IOP’s 15.14 ± 4.00 mmHg before and 14.98 ± 3.33 mmHg after the VF (P = 0.4). The average change in IOP was 0.15 ± 1.82 mmHg. Using multivariate analysis, no effect of the VF test on IOP was found (global model fit R2 = 0.12), whether based on duration of the VF test (P = 0.18) or the MD (P = 0.7) after adjustment for age, gender, CCT and history of glaucoma surgery. Similarly, there was no significant difference within different types of glaucoma, including open-angle glaucoma (P = 0.36), chronic angle closure glaucoma (P = 0.85) and OHT (P = 0.42). The subgroup of patients with an IOP elevation ≥2 mmHg had a significantly higher VF test duration (P = 0.002). Conclusion VF testing does not influence IOP as measured with a non-contact tonometer.


2020 ◽  
Author(s):  
S Bertaud ◽  
E Skarbek Borowski ◽  
R Abbas ◽  
C Baudouin ◽  
A Labbé

Abstract Background: To evaluate the influence of automated visual field (VF) testing on intraocular pressure (IOP) in patients with ocular hypertension (OHT) or glaucoma.Methods: We conducted a prospective observational study in the glaucoma department at Quinze-Vingts National Ophthalmology Hospital in Paris. Ninety-five right eyes of 95 patients followed for glaucoma or OHT were included. IOP was measured three times using a Nidek NT-510 non-contact tonometer within a maximum of 5 minutes before and after VF testing. Sub analyses using logistic regression analysis were performed to evaluate the impact of gender, age, central corneal thickness (CCT), mean deviation (MD) of the VF, VF test duration and filtration surgery on IOP fluctuations.Results: There was no significant change in IOP after VF testing, with IOP’s 15.14 ± 4.00 mmHg before and 14.98 ± 3.33 mmHg after the VF (P = 0.4). The average change in IOP was 0.15 ± 1.82 mmHg. Using multivariate analysis, no effect of the VF test on IOP was found (global model fit R²=0.12), whether based on duration of the VF test (P=0.18) or the MD (P=0.7) after adjustment for age, gender, CCT and history of glaucoma surgery. Similarly, there was no significant difference within different types of glaucoma, including open-angle glaucoma (P=0.36), chronic angle closure glaucoma (P=0.85) and OHT (P=0.42). The subgroup of patients with an IOP elevation ≥ 2mmHg had a significantly higher VF test duration (P=0.002).


2020 ◽  
Vol 2020 ◽  
pp. 1-6 ◽  
Author(s):  
Mengwei Li ◽  
Bingxin Zheng ◽  
Qi Wang ◽  
Xinghuai Sun

Purpose. To compare the impact of visual field (VF) testing on intraocular pressure (IOP) change trends between healthy subjects and glaucoma patients. Methods. We recruited healthy volunteer subjects who did not have previous ocular diseases and open-angle glaucoma patients who were medically controlled well. IOP in both eyes of each participant was measured by using a noncontact tonometer at five time points: before, immediately after (0 minute), and 10, 30, and 60 minutes after the standard automated perimetry. Repeated measures ANOVA was used to analyze the effect of VF testing on IOP change trends in healthy and glaucoma eyes. Results. Forty healthy subjects (80 eyes) and 31 open-angle glaucoma patients (62 eyes) were included for the study. The baseline IOP of healthy and glaucoma eyes was 16.11 ± 3.01 mmHg and 15.78 ± 3.57 mmHg, respectively. After the VF testing, the IOP in healthy eyes was decreased by 1.5% at 0 minute, 6.5% at 10 minutes (P<0.001), 6.6% at 30 minutes (P<0.001), and 7.0% at 1 hour (P<0.001), indicating that this reduction was sustained for at least 1 hour. However, the IOP in glaucoma eyes was increased by 12.7% at 0 minute (P<0.001) and, then, returned towards initial values 1 hour after the VF testing. Conclusions. IOP change trends after VF field testing between healthy subjects and glaucoma patients were quite different. VF testing led to a mild and relatively sustained IOP decrease in healthy subjects, whereas IOP in open-angle glaucoma patients tended to significantly increase immediately after VF testing and, then, returned to pretest values after 1 hour. These findings indicate that the factors of VF testing should be considered in the clinical IOP measurements.


2019 ◽  
Vol 104 (1) ◽  
pp. 121-126 ◽  
Author(s):  
Riccardo Vinciguerra ◽  
Salwah Rehman ◽  
Neeru A Vallabh ◽  
Mark Batterbury ◽  
Gabriela Czanner ◽  
...  

AimsTo compare the biomechanically corrected intraocular pressure (IOP) estimate (bIOP) provided by the Corvis-ST with Goldmann applanation tonometry (GAT-IOP) in patients with high-tension and normal-tension primary open-angle glaucoma (POAG; HTG and NTG), ocular hypertension (OHT) and controls. Moreover, we compared dynamic corneal response parameters (DCRs) of the Corvis-ST in POAG, OHT and controls, evaluated the correlation between global visual field parameters mean deviation and pattern SD (MD and PSD) and DCRs in the POAG group.Methods156 eyes of 156 patients were included in this prospective, single-centre, observational study, namely 41 HTG and 33 NTG, 45 OHT cases and 37 controls. Central corneal thickness (CCT), GAT-IOP and bIOP were measured, GAT-IOP was also adjusted for CCT (GATAdj). DCRs provided by Corvis-ST were evaluated, MD and PSD were recorded by 24–2 full-threshold visual field. To evaluate the difference in DCRs between OHT, HTG and NTG, a general linear model was used with sex, medications and group as fixed factors and bIOP and age as covariates.ResultsThere was a significant difference between GAT-IOP, GATAdj and bIOP in NTG and HTG, OHT and controls. NTG corneas were significantly softer and more deformable compared with controls, OHT and HTG as demonstrated by significantly lower values of stiffness parameters A1 and highest concavity and higher values of inverse concave radius (all p<0.05). There was a significant correlation (p<0.05) between MD, PSD and many DCRs with POAG patients with softer or more compliant corneas more likely to show visual field defects.ConclusionsCorneal biomechanics might be a significant confounding factor for IOP measurement that should be considered in clinical decision-making. The abnormality of corneal biomechanics in NTG and the significant correlation with visual field parameters might suggest a new risk factor for the development or progression of NTG.


2013 ◽  
Vol 2013 ◽  
pp. 1-5 ◽  
Author(s):  
Chang Mok Lee ◽  
Young Cheol Yoo

Purpose. To evaluate the short-term effect of standard automated perimetry (SAP) testing on intraocular pressure (IOP) in patients with open-angle glaucoma (OAG). Methods. We tested 45 patients (71 eyes) with OAG that had stable IOP under medical treatment. IOP was measured four times using an iCare rebound tonometer (RBT) immediately before, immediately after, 10 minutes after, and 20 minutes after SAP testing. Logistic regression analyses were performed to determine the relationships among SAP test duration, mean deviation of the SAP result, type of glaucoma medications, patient age, and significant IOP change (exceeding 2 mmHg) from baseline IOP. Results. The mean baseline IOP was 13.29 ± 3.06 mmHg. Although IOP changes immediately and 20 minutes after SAP testing were not statistically significant, the IOP change 10 minutes after SAP testing (−0.57 ± 1.84 mmHg) was statistically significant. However, the changes were within the margin of error of the RBT. Test duration, mean deviation, patient age, and type of glaucoma medications did not have a significant influence on IOP change (all ). Conclusions. IOP measured by RBT did not vary significantly after SAP testing in patients with OAG. It may be not necessary to reject IOP measured after SAP testing in patients with OAG.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Alexandru Lavric ◽  
Valentin Popa ◽  
Hidenori Takahashi ◽  
Rossen M. Hazarbassanov ◽  
Siamak Yousefi

AbstractThe main goal of this study is to identify the association between corneal shape, elevation, and thickness parameters and visual field damage using machine learning. A total of 676 eyes from 568 patients from the Jichi Medical University in Japan were included in this study. Corneal topography, pachymetry, and elevation images were obtained using anterior segment optical coherence tomography (OCT) and visual field tests were collected using standard automated perimetry with 24-2 Swedish Interactive Threshold Algorithm. The association between corneal structural parameters and visual field damage was investigated using machine learning and evaluated through tenfold cross-validation of the area under the receiver operating characteristic curves (AUC). The average mean deviation was − 8.0 dB and the average central corneal thickness (CCT) was 513.1 µm. Using ensemble machine learning bagged trees classifiers, we detected visual field abnormality from corneal parameters with an AUC of 0.83. Using a tree-based machine learning classifier, we detected four visual field severity levels from corneal parameters with an AUC of 0.74. Although CCT and corneal hysteresis have long been accepted as predictors of glaucoma development and future visual field loss, corneal shape and elevation parameters may also predict glaucoma-induced visual functional loss.


2021 ◽  
pp. bjophthalmol-2020-318304
Author(s):  
Hiroshi Murata ◽  
Ryo Asaoka ◽  
Yuri Fujino ◽  
Masato Matsuura ◽  
Kazunori Hirasawa ◽  
...  

Background/aimsWe previously reported that the visual field (VF) prediction model using the variational Bayes linear regression (VBLR) is useful for accurately predicting VF progression in glaucoma (Invest Ophthalmol Vis Sci. 2014, 2018). We constructed a VF measurement algorithm using VBLR, and the purpose of this study was to investigate its usefulness.Method122 eyes of 73 patients with open-angle glaucoma were included in the current study. VF measurement was performed using the currently proposed VBLR programme with AP-7700 perimetry (KOWA). VF measurements were also conducted using the Swedish interactive thresholding algorithm (SITA) standard programme with Humphrey field analyser. VF measurements were performed using the 24–2 test grid. Visual sensitivities, test–retest reproducibility and measurement duration were compared between the two algorithms.ResultMean mean deviation (MD) values with SITA standard were −7.9 and −8.7 dB (first and second measurements), whereas those with VBLR-VF were −8.2 and −8.0 dB, respectively. There were no significant differences across these values. The correlation coefficient of MD values between the 2 algorithms was 0.97 or 0.98. Test–retest reproducibility did not differ between the two algorithms. Mean measurement duration with SITA standard was 6 min and 02 s or 6 min and 00 s (first or second measurement), whereas a significantly shorter duration was associated with VBLR-VF (5 min and 23 s or 5 min and 30 s).ConclusionVBLR-VF reduced test duration while maintaining the same accuracy as the SITA-standard.


F1000Research ◽  
2016 ◽  
Vol 5 ◽  
pp. 762 ◽  
Author(s):  
Yalong Dang ◽  
Pritha Roy ◽  
Igor I. Bussel ◽  
Ralitsa T. Loewen ◽  
Hardik Parikh ◽  
...  

Prior glaucoma severity staging systems were mostly concerned with visual field function and retinal nerve fiber layer, but did not include intraocular pressure or medications to capture resistance to treatment. We recently introduced a simple index that combines pressure, medications, and visual field damage and applied it to stratify outcomes of trabectome surgery. In the analysis presented here, we combined data of trabectome alone and trabectome with same session cataract surgery to increase testing power and chances of effect discovery. This microincisional glaucoma surgery removes the primary resistance to outflow in glaucoma, the trabecular meshwork, and has been mostly used in mild glaucoma. Traditional glaucoma surgeries have a relatively high complication rate and have been reserved for more advanced disease stages. In the analysis presented here we include our data of trabectome combined with cataract surgery. This is a common practice pattern as both occur in the same age group with increasing frequency. For patients in higher glaucoma index (GI) groups, the intraocular pressure (IOP) reduction was 2.34+/-0.19 mmHg more than those in a GI group one level lower while holding everything else constant. Those who had undergone trabectome combined with phacoemulsification had an IOP reduction that was 1.29+/-0.39 mmHg less compared to those with trabectome alone. No statistically significant difference was found between genders and age groups while holding everything else constant. Hispanics had a 3.81+/-1.08 mmHg greater IOP reduction. Pseudoexfoliation and steroid glaucoma patients had an IOP reduction that was greater by 2.91+/-0.56 and 3.86+/-0.81 mmHg, respectively, than those with primary open angle glaucoma. These results suggest a role for trabectome-mediated ab interno trabeculectomy beyond mild forms of glaucoma. Additionally, the multifactorial glaucoma index demonstrates a role in staging patients when comparing glaucoma surgical modalities.


2007 ◽  
Vol 17 (4) ◽  
pp. 545-549 ◽  
Author(s):  
H. Shah ◽  
C. Kniestedt ◽  
A. Bostrom ◽  
R. Stamper ◽  
S. Lin

Purpose To evaluate the relationship of central corneal thickness (CCT) to baseline visual field parameters and visual field progression in patients with primary open-angle glaucoma (POAG). Methods Charts of consecutive patients with POAG were reviewed to obtain visual field data. Visual field was measured by standard threshold static perimetry. Variables analyzed included mean deviation (MD) and pattern standard deviation (PSD). Results A total of 121 eyes examined over 4 years were evaluated. A significant negative relationship between CCT and PSD (correlation coefficient: −0.02, p<0.05) was found. Analyses comparing CCT to change in PSD and MD (visual field progression) were statistically not significant. Conclusions Patients with thinner corneas initially present with a greater visual field defect, indicating that thin corneas may contribute to advanced glaucomatous damage at the time of diagnosis. However, CCT does not seem to be a significant risk factor for progression of the disease.