scholarly journals Detection of Lymph Node Metastases in Patients With Prostate Cancer: Comparing Conventional and Digital [18F]-Fluorocholine PET-CT Using Extended Pelvic Lymph Node Dissection as Reference

Author(s):  
Mimmi Bjoersdorff ◽  
Christopher Puterman ◽  
Jenny Oddstig ◽  
Jennifer Amidi ◽  
Sophia Zackrisson ◽  
...  

Abstract Background: Positron emission tomography-computed tomography (PET-CT) can be used to detect and stage metastatic lymph nodes in intermediate to high-risk prostate cancer. Improvements to hardware, such as digital technology, and to software, such as reconstruction algorithms, have recently been made. We compared the capability of detecting regional lymph node metastases using conventional and digital silicon photomultiplier (SiPM)-based PET-CT technology for [18F]-fluorocholine (FCH). Extended pelvic lymph node dissection (ePLND) histopathology was used as the reference method.Methods: Retrospectively, a consecutive series of patients with prostate cancer who had undergone staging with FCH PET-CT before ePLND were included. Images were obtained with either a conventional or a SiPM-based PET-CT and compared. FCH uptake in pelvic lymph nodes beyond the uptake in the mediastinal blood pool was considered to be abnormal.Results: One hundred eighty patients with intermediate or high-risk prostate cancer were examined using a conventional Philips Gemini PET-CT (n = 93) between 2015 and 2017 or a digital GE Discovery MI PET-CT (n = 87) from 2017 to 2018. Images that were obtained using the Philips Gemini PET-CT system showed 19 patients (20%) with suspected lymph node metastases compared with 40 patients (46%) using the GE Discovery MI PET-CT. Sensitivity, specificity, and positive and negative predictive value (PPV and NPV) were 0.30, 0.84, 0.47, and 0.72, respectively, for the Philips Gemini and 0.60, 0.58, 0.30, and 0.83, respectively for GE Discovery MI. Area under the curve (AUC) in a receiver operating characteristics (ROC) analysis was similar between the two PET-CT systems (0.58 and 0.58, P = 0.8).Conclusions: A marked difference in sensitivity and specificity was found for the different PET-CT systems. Independent of the PET-CT system, the overall diagnostic performance was poor (but similar), and FCH PET-CT should not be used for initial staging of patients with prostate cancer.

2021 ◽  
Author(s):  
Mimmi Bjöersdorff ◽  
Christopher Puterman ◽  
Jenny Oddstig ◽  
Jennifer Amidi ◽  
Sophia Zackrisson ◽  
...  

Abstract Background: Positron emission tomography-computed tomography (PET-CT) can be used to detect and stage metastatic lymph nodes in intermediate to high-risk prostate cancer. Improvements to hardware, such as digital technology, and to software, such as reconstruction algorithms, have recently been made. We compared the capability of detecting regional lymph node metastases using conventional and digital silicon photomultiplier (SiPM)-based PET-CT technology for [18F]-fluorocholine (FCH). Extended pelvic lymph node dissection (ePLND) histopathology was used as the reference method.Methods: Retrospectively, a consecutive series of patients with prostate cancer who had undergone staging with FCH PET-CT before ePLND were included. Images were obtained with either a conventional or a SiPM-based PET-CT and compared. FCH uptake in pelvic lymph nodes beyond the uptake in the mediastinal blood pool was considered to be abnormal.Results: One hundred eighty patients with intermediate or high-risk prostate cancer were examined using a conventional Philips Gemini PET-CT (n = 93) between 2015 and 2017 or a digital GE Discovery MI PET-CT (n = 87) from 2017 to 2018. Images that were obtained using the Philips Gemini PET-CT system showed 19 patients (20%) with suspected lymph node metastases compared with 40 patients (46%) using the GE Discovery MI PET-CT. Sensitivity, specificity, and positive and negative predictive value (PPV and NPV) were 0.30, 0.84, 0.47, and 0.72, respectively, for the Philips Gemini and 0.60, 0.58, 0.30, and 0.83, respectively for GE Discovery MI. Area under the curve (AUC) in a receiver operating characteristics (ROC) analysis was similar between the two PET-CT systems (0.58 and 0.58, P = 0.8).Conclusions: A marked difference in sensitivity and specificity was found for the different PET-CT systems, although similar overall diagnostic performance. This is probably due to differences in both hard- and software, including reconstruction algorithms, and should be considered when new technology is introduced.


Author(s):  
Florian Szigeti ◽  
Gregor Schweighofer-Zwink ◽  
Matthias Meissnitzer ◽  
Cornelia Hauser-Kronberger ◽  
Wolfgang Hitzl ◽  
...  

Abstract Purpose The main objective of this prospective study was to assess the value of gallium-68 prostate-specific membrane antigen ([68 Ga]Ga-PSMA-11) positron emission tomography/computed tomography (PET/CT) in primary N and M staging of intermediate- and high-risk prostate cancer (PCa) patients before planned curative-intent radical prostatectomy (RPE) and extended pelvic lymph node dissection (ePLND). The second objective was to compare the [68 Ga]Ga-PSMA-11 PET/CT findings with standard of care pelvic multi-parametric magnetic resonance imaging (mpMRI) in the detection of locoregional lymph node metastases and intraprostatic prostate cancer. Procedures A total of 81 patients (mean age: 64.5 years, baseline mean trigger PSA (tPSA) 15.4 ng/ml, ± 15.9) with biopsy proven PCa (24 intermediate- and 57 high risk) scheduled for RPE and ePLND were enrolled in this prospective study. In 52 patients [68 Ga]Ga-PSMA-11 PET/CT, pelvic mpMRI, and RPE with ePLND have been performed. Clinical risk stratification and related biomarkers as well as Gleason score (GS) were recorded. The location of the index lesion (IL) was documented systematically for each modality using a standardized segmentation of the prostate in six segments. Distant bone and lymph node metastasis detected by [68 Ga]Ga-PSMA-11 PET/CT were documented. [68 Ga]Ga-PSMA-11 PET/CT findings were correlated with results of mpMRI and histopathology. A consensus of imaging, clinical and/or follow-up findings were used for determining the distant metastases, which were not verified by histopathology. Results In the patient cohort who underwent RPE, [68 Ga]Ga-PSMA-11 PET/CT and mpMRI detected the IL in 86.5% and 98.1% of the patients, respectively. The median of the maximum standardized uptake value (SUVmax) in the intraprostatic IL was 12 (range, 4.7–67.8). Intraprostatic IL of the high-risk patients showed significantly higher SUVmax than those in patients with intermediate risk for distant metastases (n = 48; median: 17.84 vs. 8.77; p = 0.02). In total 729 LN were removed by ePLND in 48 patients. The histopathology verified 26 pelvic lymph node metastases (pLNM) in 20.8% (10/48) of the patients, which have been correctly identified in 60% of the patients on [68 Ga]Ga-PSMA-11 PET/CT, and in 50% on mpMRI. All but one pLNM had a maximum diameter below 10 mm. Bone metastases (BM) and distant LNM (dLNM) were found in 17.3% of the patients on [68 Ga]Ga-PSMA-11 PET/CT imaging. 39.0% of the [68 Ga]Ga-PSMA-11 PET-positive BM showed no suspicious morphological correlation on CT. Conclusion [68 Ga]Ga-PSMA-11 PET/CT shows high diagnostic performance for N and M staging of patients with intermediate- and high-risk prostate cancer and seems to be superior to pelvic mpMRI in the detection of locoregional lymph node metastases. A significant correlation was found between SUVmax of the intraprostatic index lesion and risk stratification based on tPSA level and GS. The results of this study emphasize again on the role of metabolic molecular imaging using specific tracers in selected patients, leading to tailored therapy approach.


2017 ◽  
Vol 121 (3) ◽  
pp. 421-427 ◽  
Author(s):  
Giorgio Gandaglia ◽  
Emanuele Zaffuto ◽  
Nicola Fossati ◽  
Marco Bandini ◽  
Nazareno Suardi ◽  
...  

Urology ◽  
2006 ◽  
Vol 68 (4) ◽  
pp. 883-887 ◽  
Author(s):  
Stephen F. Wyler ◽  
Tullio Sulser ◽  
Hans-Helge Seifert ◽  
Robin Ruszat ◽  
Thomas H. Forster ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document