Sensor fault diagnosis in a wastewater treatment process

2006 ◽  
Vol 53 (1) ◽  
pp. 251-257 ◽  
Author(s):  
C. Lee ◽  
S.W. Choi ◽  
I.-B. Lee

There are many sensors in a wastewater treatment process (WWTP) plant for monitoring process performance and condition. Sensor validation is essential to the success of process monitoring. In this paper, various sensor faults which can occur in WWTP are identified for taking proper remedial action at an early time. A proposed sensor fault isolation method is based on the variable reconstruction using principal component analysis (PCA). Even though several methods have been developed to identify sensor faults, they are only applicable to a static process. In other words, they cannot be successfully used to monitor severe dynamic processes such as WWTPs. We have removed this limitation by developing reconstruction methods based on a dynamic version of PCA. Artificial scenarios of sensor faults generated from the simulation benchmark have been used to validate the proposed sensor identifying methodology. Also, it is compared to a previous method to show its relative superiority in sensor fault validation in the WWTP.

2012 ◽  
Vol 178-181 ◽  
pp. 599-602
Author(s):  
Shu Xin Du ◽  
Yuan Qing Wu ◽  
Zhi Bao Yuan

In the wastewater treatment process, it is necessary to detect the concentrations of organic matter in order to monitor the operation and adjust the process parameters. Based on fluorescence excitation-emission matrix spectrometry, Chemical oxygen demand (COD) of effluent wastewater in the primary sedimentation tank, the secondary sedimentation tank and the final sedimentation tank of Hengdian Wastewater Treatment Plant, Zhejiang Province, is detected respectively based on fluorescence excitation-emission matrix spectrometry. In order to compare the modeling performance, principal component regression (PCR), partial least squares (PLS), parallel factor analysis (PARAFAC) and multi-way partial least squares (N-PLS) are respectively used to build the calibration models between the fluorescence spectrometry and COD. Experimental results show PLS is better than PARAFAC and N-PLS in the aspect of modeling performance for detecting COD in the wastewater.


1995 ◽  
Vol 31 (5-6) ◽  
pp. 85-89 ◽  
Author(s):  
S. J. Turner ◽  
G. D. Lewis

Over a 12 month period F-specific bacteriophages, faecal coliforms and enterococci were compared as microbial indicator organisms for the quality of a wastewater treatment (oxidation pond) system. Results suggest that enterococci may be the most useful indicator for oxidation pond systems.


Sign in / Sign up

Export Citation Format

Share Document