In this paper, the physico-chemical treatment of municipal wastewater for the simultaneous removal of pollutant indicators (chemical oxygen demand (COD) and total coliforms) and organic contaminants (total phenols) was investigated and assessed. A secondary settled effluent was subjected to coagulation, disinfection and absorption in a multifunctional reactor by dosing, simultaneously, aluminum polychloride (dose range: 0–150 μL/L), natural zeolites (dose range: 0–150 mg/L), sodium hypochlorite (dose range: 0–7.5 mg/L) and powder activated carbon (dose range: 0–30 mg/L). The treatment process was optimized using computational fluid dynamics (CFD) and response surface methodology. Specifically, a Latin square technique was employed to generate 16 combinations of treating agent types and concentrations which were pilot tested on an 8 m3/h multifunctional reactor fed by a secondary effluent with COD and total coliform concentrations ranging from ≈20 to 120 mg/L and from 105 to 106 CFU/100 mL, respectively. Results were promising, indicating that removal yields up to 71% in COD and 5.4 log in total coliforms were obtained using an optimal combination of aluminum polychloride (dose range ≈ 84–106 μL/L), powder activated carbon ≈ 5 mg/L, natural zeolite (dose range ≈ 34–70 mg/L) and sodium hypochlorite (dose range ≈ 3.4–5.6 mg/L), with all treating agents playing a statistically significant role in determining the overall treatment performance. Remarkably, the combined process was also able to remove ≈ 50% of total phenols, a micropollutant known to be recalcitrant to conventional wastewater treatments.

1972 ◽  
Vol 7 (1) ◽  
pp. 1-12
Author(s):  
A. Benedek

Abstract Recent developments in the application of activated carbon to wastewater treatment are reviewed. Particular emphasis is placed on the physico-chemical treatment of municipal waste. Technological development, adsorptive behaviour, and research needs serve as the three primary discussion topics.


2013 ◽  
Vol 9 (2) ◽  
pp. 166-173

The present study investigated tertiary physico-chemical treatment of the secondary effluent from the Chania municipal Wastewater Treatment Plant (WTP). Laboratory experiments were carried out with the aim of studying coagulation efficiency regarding reduction of turbidity, soluble COD and phosphorus both in a conventional Coagulation-Settling treatment scheme, as well as by means of Contact Filtration. The results showed that high doses of coagulants (0,5 mmol Me+3 l-1 or higher) are required to achieve significant removals of turbidity after settling. At these high doses, soluble COD can be removed by about 50%, while soluble Phosphorus by 80-95%. Ferric Chloride demonstrated slightly better removal ability as compared to Alum. The Chania WTP effluent was also treated by Contact Filtration, using a very low dose of coagulants, 0,1 mmol Me+3 l-1. Turbidity was removed by around 50%, while at this low coagulant dose removals of COD and Phosphorus were insignificant. Filtration was effective in the first 35cm of the filter bed. No significant differences were observed between the coagulants Alum and FeCl3 in the elimination of turbidity. Nevertheless, with the use of Alum a smaller filter headloss was observed, during the first two hours of continuous filtration, in comparison with the use of FeCl3 (nearly double). No difference was observed between the headloss developed at a filter depth of 5cm as compared to that developed at a depth of 70cm. This indicates that the headloss increase was due to the accumulation of suspended and colloidal solids within the first layers of the sand filter.


2021 ◽  
Vol 958 (1) ◽  
pp. 012020
Author(s):  
M Mayacela ◽  
L Maldonado ◽  
F Morales ◽  
B Suquillo

Abstract In Ecuador, contaminated water is discharged directly into the sewage system. The treatments carried out for the elimination of wastewater pollutants are classified into three types: Physical, Chemical and Biological. One of the treatments that is frequently used is the physico-chemical treatment in which various reactive substances are used, which is why in this research several reactive substances of Ecuadorian origin, including activated carbon, peat, limestone, volcanic pyroclasts, zeolite clinoptilolite and zeolite modernite, are physically characterized. For this purpose, some laboratory tests were carried out based on national and international standards in order to obtain the granulometry, compactness coefficient, porosity, sphericity and permea-bility.


2012 ◽  
Vol 66 (10) ◽  
pp. 2115-2121 ◽  
Author(s):  
M. Boehler ◽  
B. Zwickenpflug ◽  
J. Hollender ◽  
T. Ternes ◽  
A. Joss ◽  
...  

Micropollutants (MP) are only partly removed from municipal wastewater by nutrient removal plants and are seen increasingly as a threat to aquatic ecosystems and to the safety of drinking water resources. The addition of powder activated carbon (PAC) is a promising technology to complement municipal nutrient removal plants in order to achieve a significant reduction of MPs and ecotoxicity in receiving waters. This paper presents the salient outcomes of pilot- and full-scale applications of PAC addition in different flow schemes for micropollutant removal in municipal wastewater treatment plants (WWTPs). The sorption efficiency of PAC is reduced with increasing dissolved organic carbon (DOC). Adequate treatment of secondary effluent with 5–10 g DOC m−3 requires 10–20 g PAC m−3 of effluent. Counter-current use of PAC by recycling waste PAC from post-treatment in a contact tank with an additional clarifier to the biology tank improved the overall MP removal by 10 to 50% compared with effluent PAC application alone. A dosage of 15 g PAC m−3 to a full-scale flocculation sand filtration system and recycling the backwash water to the biology tank showed similar MP elimination. Due to an adequate mixing regime and the addition of adapted flocculants, a good retention of the fine fraction of the PAC in the deep-bed filter were observed (1–3 g TSS m−3; TSS: total suspended solids). With double use of PAC, only half of the PAC was required to reach MP removal efficiencies similar to the direct single dosage of PAC to the biology tank. Overall, the application of PAC in WWTPs seems to be an adequate and feasible technology for efficient MP elimination (>80%) from wastewater comparable with post ozonation.