scholarly journals A NUMERICAL RESEARCH OF THE RANGE OF NORMAL MODES OF AN OPEN INHOMOGENEOUS WAVEGUIDE WITH CIRCULAR CROSS-SECTION

Author(s):  
E. Yu. Smol'kin ◽  
◽  
M. O. Snegur ◽  
E. A. Khorosheva ◽  
◽  
...  
2018 ◽  
Vol 8 (1) ◽  
pp. 322-328
Author(s):  
Moloshnyi Oleksandr ◽  
Szulc Przemyslaw

Abstract The paper concerns the analysis of the cavitation processes in the flow passages of the radial labyrinth pump. The object of the analysis contains the active (moving) and the passive (stationary) discs with straight channels trajectory and semi-circular cross-section. The conversion of the mechanical energy into hydraulic based on the exchange of the momentum between the liquid remaining in the moving and the stationary areas of the discs as well as on the centrifugal increase of the moment of momentum. The analysis of the cavitation processes was realized by the experimental research and the numerical simulation. In the article, the comparison of the cavitation characteristics was carried out. The numerical simulation had given similar results to the experimental one, the process of the cavitation was visualized. Furthermore, numerical investigations helped to describe the cavitation development. The results of the numerical research such as the distributions of the velocity, pressure and vapor volume fraction in the passages were presented. At first, cavitation starts on the back side and on the top of the wall between channels of the active disc. Further, the cavitation areas are growing along the axis of the channels. Eventually, they separation was observed and vortices of the vapour-gas mixture in the middle of the channels were formed. This phenomenon is so-called super cavitation vortices.


2018 ◽  
Vol 14 (1) ◽  
pp. 1
Author(s):  
Prof. Dr. Jamal Aziz Mehdi

The biological objectives of root canal treatment have not changed over the recentdecades, but the methods to attain these goals have been greatly modified. Theintroduction of NiTi rotary files represents a major leap in the development ofendodontic instruments, with a wide variety of sophisticated instruments presentlyavailable (1, 2).Whatever their modification or improvement, all of these instruments have onething in common: they consist of a metal core with some type of rotating blade thatmachines the canal with a circular motion using flutes to carry the dentin chips anddebris coronally. Consequently, all rotary NiTi files will machine the root canal to acylindrical bore with a circular cross-section if the clinician applies them in a strictboring manner


Sign in / Sign up

Export Citation Format

Share Document