scholarly journals Computational fluid dynamics assessment: Volume 2, Isothermal simulations of the METC bench-scale coal-water slurry combustor: Final report

1988 ◽  
Author(s):  
I. Celik ◽  
M. Chattree
2014 ◽  
Vol 592-594 ◽  
pp. 869-873 ◽  
Author(s):  
Arunanshu Chakravarthy ◽  
Satish Kumar ◽  
S.K. Mohapatra

The rheological behaviour of concentrated coal-water slurries prepared from three different Indian coals were investigated using an Anton Paar rheometer. The perspective was laid in to study the effect of solids concentration on the rheological behaviour of coal water slurry. It was observed that coal water slurry exhibited non-Newtonian pseudoplastic fluid behaviour at concentrations above 30 % by weight. The apparent viscosity varied with the amount of coal in the slurry. The rheological data were utilized to predict the pressure drop characteristics of coal water slurry flowing through a 53 mm diameter slurry pipeline using ANSYS Fluent 14.0 computational fluid dynamics code.


Author(s):  
Junfeng Lian ◽  
Liangmin Sun ◽  
Chong Jiang ◽  
Wentao Li ◽  
Yichun Zhu ◽  
...  

Abstract Quasi-collimated beam apparatus (QCBA), a typical bench scale UV apparatus, is crucial for the biodosimetry determination of UV dose in target reactors. However, the key parameters for the QCBA construction are usually estimated via rule-of-thumb calculations. Computational fluid dynamics models are applied in this study to simulate the UV fluence rate (FR) distributions in QCBAs. QCBAs with either a cylindrical tube or successive apertures irradiate quasi parallel light into selected dishes. The simulated Petri factor (PF) in the target QCBAs with a single aperture were all >0.84, and increased with the extended distance (L1) from the UV lamp to the upper aperture. QCBAs with two successive apertures are recommended compared with those with three apertures or cylindrical tube. A trend of FR distribution from dispersed to concentrated is observed when L1 or the interval distance between each aperture increases in a dual-aperture QCBA. QCBAs with multiple lamps were favorable to increase the UV output power, while having a nearly negligible loss of parallelism. An actual QCBA was constructed, and the maximal and average FR, and PF values in a 60-mm dish were 0.159 and 0.164 W/m2, and 0.967, respectively, in accordance with the simulated results.


2014 ◽  
Vol 254 ◽  
pp. 125-130 ◽  
Author(s):  
Qinghua Guo ◽  
Yan Gong ◽  
Jianliang Xu ◽  
Guangsuo Yu ◽  
Fuchen Wang

Sign in / Sign up

Export Citation Format

Share Document