A New Short Validated U-HPLC Method for the Determination of Recombinant Human Insulin in Microspheres

2018 ◽  
Vol 14 (5) ◽  
pp. 501-512
Author(s):  
Pravin Wakte ◽  
Gauravkumar Agrawal ◽  
Santosh Shelke
2010 ◽  
Vol 7 (s1) ◽  
pp. S449-S457 ◽  
Author(s):  
B. A. Moussa ◽  
F. Farouk ◽  
H. M. E. Azzazy

A modified RP-HPLC method was developed for the quantitative determination of recombinant human insulin in bulk and pharmaceutical dosage form with reduced retention time. Study of the effects of the column temperature, pH of the mobile phase and presence of vial additives (phenol andm-cresol), or impurities (A-21 Disamido) on the accuracy of the assay were assessed. Separation was achieved using a Hypersil BDS C-18 column and the mobile phase was composed of solution A (aqueous solution of 28.3 anhydrous Na2SO4g/L, pH 2.3) and solution B (28.5 g anhydrous Na2SO4g/L in 50:50 mixture of water and acetonitrile, pH 2.3) in a ratio 48:52 (v/v) at 45–50°C. The column temperature was 40°C, the flow rate was 1 mL/min and detection was performed at 216 nm. The procedures were validated according to international conference on harmonization (ICH) guidelines. Recovery study was done applying standard addition technique for further validation of the procedure. The retention time of recombinant human insulin was 19.7 min as compared to 29 min obtained by the reference method. Analytical conditions fluctuations or presence of vial additives or impurities did not show any significant effect on the accuracy of the method. The prepared standard insulin solution in 0.01 N HCl was found to be stable for 5 days. Statistical comparison showed no significant difference between the described method and reference method regarding the accuracy and precision. The modified method can be applied for routine quality control applications for determination of recombinant human insulin.


2012 ◽  
Vol 2 (2) ◽  
pp. 364-367 ◽  
Author(s):  
Saida Naik Dheeravath ◽  
◽  
Kasani Ramadevi ◽  
Zilla Saraswathi ◽  
Dheeravath Maniklal ◽  
...  

2019 ◽  
Vol 9 (o3) ◽  
Author(s):  
Imad Tarek Hanoon ◽  
Abed Mohammed Daheir AL-Joubory 2 ◽  
Marwa Mohamed Saied 3

A simple , specific, accurate and precise RP-HPLC method was developed for determination of Irbesartan (IRB) in pharmaceutical dosage forms in tablets products and sachet using symmetry (L 1 ) column at 30°C . The signal was detected at 225 nm. A mobile phase dissolve 0.5 g of buffer potassium phosphate in 100 ml distilled water and adjust pH 2.7 , methanol and acetonitrile at ratio (40 :30 :30 ) . and flow rate 1.2ml/min -1 at pH=7.2 a mobile phase The percent recovery was detected 101 % and the linearity of concentration was 10-50 µg.ml -1 and supported this method by using (FT.I.R.) spectrum method for organic spectrophotometer to prove the chemical structure of this drug and some physical properties . we are obtained the result is identical of other literature . The proposed method was applied successfully for determination of the IRB in tablets products.


Sign in / Sign up

Export Citation Format

Share Document