scholarly journals Extractive Spectrophotometric Determination of Niobium (V) Using 3- Hydroxy-2-(4'-Methoxyphenyl)-4-Oxo-4H-l-Benzopyran as a Complexing Agent

2012 ◽  
Vol 6 (1) ◽  
pp. 39-44 ◽  
Author(s):  
Nivedita Agnihotri
RSC Advances ◽  
2015 ◽  
Vol 5 (80) ◽  
pp. 65321-65327 ◽  
Author(s):  
Chunlei Fan ◽  
Shengxu Luo ◽  
Rong Liu

BTF is exists with spirolactone species with adding Cu2+, which leads to the absorbance intensity is decreased gradually and the decrease of the absorbance value is linear for Cu2+.


2014 ◽  
Vol 11 (1) ◽  
pp. 147-157
Author(s):  
Baghdad Science Journal

The new organic reagent 2-[Benzo thiazolyl azo]-4,5-diphenyl imidazole was prepared and used as complexing agent for separation and spectrophotometric determination of Cu2+ ion in some samples include plants, soil, water and human blood serum. Initially determined all factors effect on extraction method and the results show optimum pH was (pHex=9), optimum concentration was 40?g/5mLCu2+ and optimum shaking time was (15min.), as well stoichiometry study appears the complex structure was 1:1 Cu2+: BTADPI. Interferences effect of cations were studied. Synergism effect shows MIBK gave increasing in distribution ratio (D). Organic solvent effect appears there is no any linear relation between dielectric constant for organic solvent used and distribution ration (D). Thermodynamically found the reaction was Endothermic reaction, with ?Hex= 0.0131 KJ.mole-1,?Gex=-54.20 KJ.mole-1 ,?Sex= 167.84 J.mole-1.Beer’s law was obeyed over the concentration 1-30?g/5mL, and ?=922.90 Lmol-1.cm-1,with detection limit 1.7×10-5and Sandell’s sensitivity 6.8× 10-7 gcm-2.


2009 ◽  
Vol 34 (2) ◽  
pp. 7-13 ◽  
Author(s):  
P. A. Antunes ◽  
G. Bannach ◽  
G. O. Chierice ◽  
E. T. G. Cavalheiro

A direct spectrophotometric method for simultaneous determination of Co(II) and Ni(II), with diethanoldithiocarbamate (DEDC) as complexing agent, is proposed using the maximum absorption at 360 and 638 nm (Co(II)/DEDC) and 390 nm (Ni/DEDC). Adjusting the best metal/ligand ratio, supporting eletrolite, pH, and time of analysis, linear analytical curves from 1.0 10-6-4.0 10-4 for Co(II) in the presence of Ni 1.0 10-6-1.0 10-4 mol L-1 were observed. No further treatment or calculation processes have been necessary. Recoveries in different mixing ratios were of 99%. Interference of Fe(III), Cu(II), Zn(II) and Cd(II), and anions as NO3-, Cl-, ClO4-, citrate and phosphate has been evaluated. The method was applied to natural waters spiked with the cations.


Sign in / Sign up

Export Citation Format

Share Document