scholarly journals Long Term Survivorship of a Severely Notched Femoral Stem after Replacing the Fractured Ceramic head with a Cobalt-Chromium Head

2016 ◽  
Vol 10 (1) ◽  
pp. 779-784 ◽  
Author(s):  
Andreas Panagopoulos ◽  
Irini Tatani ◽  
Panagiotis Megas

Background: Although ceramic head fracture occurs infrequently today, in the event of a fracture, the resulting revision surgery can prove very challenging, since the ceramic particles lodge into the surrounding soft tissue and can cause rapid implant failure Case Presentation: A case of long term survivorship of a severed notched femoral stem after replacing the fractured femoral head with a cobalt-chromium one is reported in a 40-year old woman with hip dysplasia who underwent an uncomplicated total hip arthroplasty. The incident of ceramic femoral head fracture occurred 14 months postoperatively without reporting any significant trauma. Intraoperative findings at revision were a multifragmented femoral head and a damaged polyethylene insert along with diffuse metallosis and excessive wear of the cone of the stem. Both the stem and the acetabular component were stable. After removal of ceramic fragments, metallotic tissue excision and careful lavage of the joint, the inlay was replaced by a similar one and a cobalt-chromium femoral head was placed to the existing notched taper of the firmly incorporated stem. At the 13th year follow up examination, the patient had no pain, used no walking aids, and had normal activity with no signs of wearing or loosening in the plain x-rays. Conclusion: Despite current recommendations of using ceramic femoral heads in cases of fracture or to revise the severely damaged stems we were able to provide a long term survivorship up to 13 years postoperatively of a cobalt-chromium femoral head applied to a severe damaged stem.

VCOT Open ◽  
2021 ◽  
Vol 04 (01) ◽  
pp. e58-e64
Author(s):  
Marcos Garcia ◽  
Camille Bismuth ◽  
Claire Deroy-Bordenave

AbstractThe aim of this study was to report the outcome in a 6-year-old male English Setter dog that suffered a combination of divergent elbow dislocation and open distal ulnar fracture. This study is a case report. After surgical reduction in the elbow luxation, the dog was treated with the TightRope fixation system used as replacement of the lateral collateral ligament, a radioulnar positional screw, and external skeletal fixation. Removal of all implants was performed 3 months postoperatively. The 6-month follow-up visit found the dog without lameness, displaying normal activity, and with normal elbow range of motion and normal Campbell's test. Successful surgical management was achieved with good long-term results using TightRope, a positional screw, and an external skeletal fixator.


2020 ◽  
Vol 5 (4) ◽  
pp. 2473011420S0032
Author(s):  
Hong S. Lee ◽  
Kiwon Young ◽  
Tae-Hoon Park ◽  
Hong Seop Lee

Category: Ankle Introduction/Purpose: Failed total ankle arthroplasty (TAA) often results in significant bone loss and requires salvage arthrodesis. The aim of this study was to investigate the outcomes of Salvage arthrodesis with allo-bone block for failed TAA. Methods: This study included 8 patients who underwent salvage arthrodesis with femoral head allograft for failed TAA from August 2012 to March 2018 because of loosing of TAA implant. The mean age of the patients was 71 years (range, 54-81 years), and the mean follow-up period was 32 months (range, 12 to 84 months). Allograft problem and alignment of joint were evaluated radiographically. American Orthopaedic Foot & Ankle Society (AOFAS) scores, Foot and Ankle Outcome Score (FAOS), and visual analogue scale (VAS) pain scores were recorded preoperatively and at the time of final followup. Functional questionnaires were used to assess the duration for which the patient could walk continuously, use of walking aids, consumption of pain medication, and the patient’s subjective assessment of the percentage of overall improvement compared with before the salvage arthrodesis. Results: The allograft was retained without collapse for a mean of 24 months (range, 12 to 36 months) in four patients. Collapse of the allograft was observed in four patients at a mean of 11 months (range, 9 to 16 months), 1 of 4 patients were conserved to retrograde intramedullary nail at postoperative 12 months because of with implant failure and nonunion. The mean AOFAS and VAS pain scores improved from 12 (range, 8 to 40) preoperatively to 63 (range, 38 to 75) postoperatively (p = 0.001) and from 7 (range, 6 to 10 to 3 (range, 2 to 8) (p = 0.001), respectively. At the final follow-up evaluation, 6 of 8 patients were able to walk continuously at least 30 minutes with walking aid. Conclusion: The successful rate of salvage arthrodesis with femoral head allograft was 75% (Six of total 8 patients). The incidence rate of allograft collapse was 50% (Four of total 8 patients).


2021 ◽  
Vol 103-B (12) ◽  
pp. 1815-1820
Author(s):  
Stefan Huhnstock ◽  
Ola Wiig ◽  
Else Merckoll ◽  
Svein Svenningsen ◽  
Terje Terjesen

Aims The aim of this study was to assess the prognostic value of the modified three-group Stulberg classification, which is based on the sphericity of the femoral head, in patients with Perthes’ disease. Methods A total of 88 patients were followed from the time of diagnosis until a mean follow-up of 21 years. Anteroposterior pelvic and frog-leg lateral radiographs were obtained at diagnosis and at follow-up of one, five, and 21 years. At the five- and 21-year follow-up, the femoral heads were classified using a modified three-group Stulberg classification (round, ovoid, or flat femoral head). Further radiological endpoints at long-term follow-up were osteoarthritis (OA) of the hip and the requirement for total hip arthroplasty (THA). Results There were 71 males (81%) and 17 females. A total of 13 patients had bilateral Perthes’ disease; thus 101 hips were analyzed. At five-year follow-up, 37 hips were round, 38 ovoid, and 26 flat. At that time, 66 hips (65%) were healed and 91 (90%) were skeletally immature. At long-term follow-up, when the mean age of the patients was 28 years (24 to 34), 20 hips had an unsatisfactory outcome (seven had OA and 13 had required THA). There was a strongly significant association between the modified Stulberg classification applied atfive-year follow-up and an unsatisfactory outcome at long-term follow-up (p < 0.001). Between the five- and 21-year follow-up, 67 hips (76%) stayed in their respective modified Stulberg group, indicating a strongly significant association between the Stulberg classifications at these follow-ups (p < 0.001). Conclusion The modified Stulberg classification is a strong predictor of long-term radiological outcome in patients with Perthes’ disease. It can be applied at the healing stage, which is usually reached five years after the diagnosis is made and before skeletal maturity. Cite this article: Bone Joint J 2021;103-B(12):1815–1820.


1988 ◽  
Vol 13 (4) ◽  
pp. 458-462
Author(s):  
H. TEISEN ◽  
J. HJARBAEK
Keyword(s):  
X Rays ◽  

The X-rays of 17 patients with fresh fractures of the lunate bone have been reviewed. The fractures were classified according to their radiological appearances and according to the vascular anatomy of the lunate. A long term X-ray follow-up examination was performed.


Author(s):  
Renée Huggard ◽  
Grace Wicks ◽  
Gordon Corfield

Abstract Objective The aim of this study was to assess the short-term clinical outcome in dogs following a hip hemi-arthroplasty for the treatment of primary pathological disorders of the hip and as a salvage procedure following failure of the cup component of a total hip replacement. Materials and Methods Medical records of dogs that had a unilateral hip hemi-arthroplasty performed between 2015 and 2020 were reviewed. Data collected included follow-up orthopaedic examinations performed at 0, 2, 8 and 52 weeks postoperatively, pelvic radiography at 0, 8 and 52 weeks postoperatively and an owner questionnaire (Helsinki chronic pain index [HCPI]). Results Eleven unilateral hip hemi-arthroplasty procedures were identified. The median age at time of surgery was 3.6 years (8 months–10 years) and the median follow-up time was 13 months (range: 2 months–3 years). The HCPI for all dogs at follow-up was median 8 ± 7.30 (range: 5–25). Total HCPI was < 12 for 7/10 dogs and ≥ 12 for 3 dogs. Pelvic radiographs at 1 year confirmed osteointergration of the femoral stem implant and no evidence of implant subsidence or progression of osteoarthritis. However, there was some evidence of mild lucency of the acetabular bed around the prosthetic femoral head and mild peri-acetabular sclerosis in four cases. Conclusion Hip hemi-arthroplasty provides a clinically acceptable treatment for disabling disease of the coxofemoral joint with 10/11 patients achieving acceptable short-term clinical function. Long-term assessment of the hip hemi-arthroplasty and comparison with total hip replacement is indicated.


Coatings ◽  
2020 ◽  
Vol 10 (5) ◽  
pp. 442 ◽  
Author(s):  
Georg Hauer ◽  
Lukas Leitner ◽  
Marc C. Ackerl ◽  
Sebastian Klim ◽  
Ines Vielgut ◽  
...  

Background: The impact of titanium nitride (TiN) coating on implant components is controversial. TiN coating is proposed as having superior biomechanical properties compared to conventional cobalt-chromium (CoCr) alloy. This study compared long-term clinical data as well as meteoro-sensitivity in patients who underwent total knee arthroplasty (TKA), with either CoCr alloy or TiN coating. Methods: In this retrospective observational study, the clinically approved cemented “low contact stress” (LCS) TKA with conventional CoCr coating, was compared to un-cemented TiN-coated “advanced coated system” (ACS) TKA. Propensity score matching identified comparable patients based on their characteristics in a one-to-one ratio using the nearest-neighbor method. The final cohort comprised 260 knees in each cohort, with a mean follow-up of 10.1 ± 1.0 years for ACS patients and 14.9 ± 3.0 years for the LCS group. Physical examinations, meteoro-sensitivity, and knee scoring were assessed. Results: The clinical and functional Knee Society Score (KSS) (82.6 vs. 70.8; p < 0.001 and 61.9 vs. 71.1; p = 0.011), the postoperative Visual Analogue Scale (VAS) (2.9 vs. 1.4; p = 0.002), and the postoperative Tegner Score (2.6 vs. 2.2; p = 0.001) showed significant intergroup differences. The postoperative Western Ontario & McMaster Universities Osteoarthritis Index (WOMAC) was similar (79.9 vs. 81.3; p = 0.453) between groups. Meteoro-sensitivity of the artificial joint was significantly more prevalent in the ACS patient cohort (56% vs. 23%; p < 0.001). Conclusion: This study suggests that TiN coating does not provide improved clinical outcomes in this patient cohort after a long-term follow-up. Interestingly, sensitivity to weather changes were more correlated with un-cemented ACS implants.


1992 ◽  
Vol 2 (2) ◽  
pp. 43-46
Author(s):  
U. Fusco ◽  
R. Capelli ◽  
A. Avai ◽  
M. Gerundini ◽  
L. Colombini ◽  
...  

Between 1980 and 1987 we have implanted 46 isoelastic cementless THR in 40 patients affected with rheumatoid arthritis. We have reviewed 38 hips clinically and by X-ray. The mean follow-up was 8,5 years. Harris hip scores ranged from 30.6 preoperatively to 73,4 post-operatively when reviewed. While on the other hand Merle D'Aubigné hip scores ranged from 7,06 pre-operatively to 15,59 post-operatively. All patients have been satisfied, and X-rays showed an improvement for both Charnely and Gruen X-ray score.


Sign in / Sign up

Export Citation Format

Share Document