scholarly journals Reevaluation of enzyme-linked immunosorbent assay with ultraviolet-treated polystyrene microtiter plates for measurement of antibodies to dsDNA.

1996 ◽  
Vol 19 (2) ◽  
pp. 163-167
Author(s):  
Junichi Kaburaki ◽  
Takashi Ogasawara ◽  
Masakatsu Hayakawa ◽  
Masataka Kuwana ◽  
Takeshi Tojo ◽  
...  
Blood ◽  
1983 ◽  
Vol 62 (4) ◽  
pp. 744-749 ◽  
Author(s):  
JD Tamerius ◽  
JG Curd ◽  
P Tani ◽  
R McMillan

Abstract The selection of platelet donors for patients who are refractory to random donor platelets often presents a difficult clinical problem. We describe an enzyme-linked immunosorbent assay (ELISA) for evaluating alloantibodies in refractory patients. Platelets from prospective donors are immobilized on microtiter plates and, after incubation with test serum and washing, platelet-bound IgG is detected with enzyme- linked anti-human IgG. Platelets from 46 prospective donors were tested. Twenty-two were judged compatible (reciprocal of the antibody titer less than 16) and, of these, 15 were used as platelet donors; each gave a measurable platelet increment after transfusion. The magnitude of the response was roughly proportional to the assay results. Platelets from donors giving antibody titers less than 4 resulted in platelet increments at 1 hr ranging from 4,890 to 22,200 (median 12,600), while platelets from donors giving titers of 8 or 16 resulted in lesser increments (550–4548). Conversely, 5 of the 24 patients found incompatible by the assay (titer greater than 16) gave no platelet increment, and in 3 instances, the recipient developed fever and chills after the transfusion. The assay is sensitive, simple, and adaptable to the clinical laboratory. Platelets from volunteer donor panels can be plated and stored for up to 6 mo.


Blood ◽  
1983 ◽  
Vol 61 (2) ◽  
pp. 311-317 ◽  
Author(s):  
CA Schiffer ◽  
V Young

Abstract An enzyme-linked immunosorbent assay (ELISA) for the measurement of circulating platelet antibody and platelet-associated IgG (PAIgG) is described. The test is done in microtiter plates and rapidly provides quantitative and highly reproducible results. Alloantibodies from 28 of 30 multiple transfused patients and isoantibodies from 3 of 4 patients with immune thrombocytopenic purpura (ITP) were detected. PAIgG was elevated in all 4 patients with ITP, and HLA and platelet-specific antigens were reliably detected using HLA typing sera and anti-PIA1 antibody, respectively. Platelets preserved wither by dessication in the wells of the microtiter plates or in liquid suspension in saline at 4 degrees C gave results comparable to values using fresh platelets. Storage periods ranged from 30 days for dessicated platelets to more than 1 yr for platelets stored in suspension. The ability to utilize preserved platelets may allow relatively convenient screening of large numbers of potential platelet donors for alloimmunized patients.


2002 ◽  
Vol 50 (22) ◽  
pp. 6266-6270 ◽  
Author(s):  
Simone Vincenzi ◽  
Gianni Zoccatelli ◽  
Fabio Perbellini ◽  
Corrado Rizzi ◽  
Roberto Chignola ◽  
...  

Blood ◽  
1983 ◽  
Vol 61 (2) ◽  
pp. 311-317
Author(s):  
CA Schiffer ◽  
V Young

An enzyme-linked immunosorbent assay (ELISA) for the measurement of circulating platelet antibody and platelet-associated IgG (PAIgG) is described. The test is done in microtiter plates and rapidly provides quantitative and highly reproducible results. Alloantibodies from 28 of 30 multiple transfused patients and isoantibodies from 3 of 4 patients with immune thrombocytopenic purpura (ITP) were detected. PAIgG was elevated in all 4 patients with ITP, and HLA and platelet-specific antigens were reliably detected using HLA typing sera and anti-PIA1 antibody, respectively. Platelets preserved wither by dessication in the wells of the microtiter plates or in liquid suspension in saline at 4 degrees C gave results comparable to values using fresh platelets. Storage periods ranged from 30 days for dessicated platelets to more than 1 yr for platelets stored in suspension. The ability to utilize preserved platelets may allow relatively convenient screening of large numbers of potential platelet donors for alloimmunized patients.


1989 ◽  
Vol 35 (8) ◽  
pp. 1770-1772 ◽  
Author(s):  
S H Chui ◽  
K C Wan ◽  
C W Lam ◽  
W H Lewis

Abstract We describe a simple enzyme-linked immunosorbent assay (ELISA) in which microtiter plates are used for determining the free thyroxin concentration (FT4) in serum. Only commercially available chemicals and reagents are needed, including the antiserum. The working range is 1 to 60 ng/L. Turnaround time is about 4 h. Within-run coefficients of variation (CV) for FT4 concentrations of 9.0, 19.0, and 35.0 ng/L were less than 5%; between-run CVs were 10% to 11%. Results by a radioimmunoassay method for 150 sera correlated well (r = 0.922).


1988 ◽  
Vol 34 (9) ◽  
pp. 1767-1771 ◽  
Author(s):  
R Saïle ◽  
C Delpierre ◽  
P Puchois ◽  
G Hocke ◽  
C Cachera ◽  
...  

Abstract We describe a noncompetitive enzyme-linked immunosorbent assay for amyloid A apolipoprotein in human serum (apo SAA) in which specific antibodies against synthetic peptides are used. Microtiter plates were used as solid phase and coated with affinity-purified antibodies raised against SAA1-(95-104) peptide. After incubation with delipidated plasmas, the bound apo SAA was revealed by labeled antibodies raised against SAA1-(58-69) peptide. The assay offers several advantages over existing techniques: sensitivity, specificity, simplicity, and non-use of radioisotopes. Results correlate well with those by a nephelometric method in which polyclonal antibodies are used.


Sign in / Sign up

Export Citation Format

Share Document