Image Fusion Augmented Angiography Improves Right Adrenal Vein Cannulation Success Rate in Adrenal Vein Sampling

Author(s):  
Iris Lee ◽  
Kenneth K. Lau
2015 ◽  
Vol 5 (3) ◽  
Author(s):  
Reza Aminnejad ◽  
Seyed Sajjad Razavi ◽  
Seyed Amir Mohajerani ◽  
Seyed Alireza Mahdavi

2021 ◽  
Vol 8 (2) ◽  
pp. 129
Author(s):  
Reena Mahajan ◽  
Suchitra Malhotra

<p><strong>Background: </strong>Ultrasound (USG) guided Internal jugular venous (IJV) cannulation is preferred than traditional approach due to increase in success rate, reduction in time taken and attempts of successful cannulation and less complications. The purpose of our study was to observe and compare three different real time 2-dimensional US-guided approaches and to determine which approach improves rate of successful cannulation, decreases complications along with shorter average time taken for the procedure. Primary outcomes of the study were venous access time, catheterization time and success rate. Secondary outcomes were number of patients requiring second attempt and complications observed.</p><p><strong>Methods: </strong>120 adult patients were randomly divided into three groups according to real time US guided cannulation done with SAX-OP approach, LAX-IP approach and OAX-IP approach. Parameters like venous access time, catheterization time, number of patients requiring second attempt and complications were noted.</p><p><strong>Results: </strong>Venous access time was shortest in LAX group 21.84±3.67 seconds which was just significant statistically. Catheterization time was shortest in LAX group 241±123 seconds. Cannulation success rate was highest in LAX group 98% and was statistically significant. Patients requiring second attempt was least in LAX group 2.5%. Posterior IJV wall puncture was observed in 10% patients in SAX group and none in LAX and OAX group which was statistically significant.</p><p><strong>Conclusions:</strong> LAX-IP showed better performance in terms of higher cannulation success, lesser average venous access time and catheterization time and lesser complications. On toggling USG probe, both IJV and carotid artery can be differentiated and carotid puncture could be avoided. Hence LAX approach is safer and effective approach.</p>


2020 ◽  
Author(s):  
Montoro José Ignacio Martínez ◽  
Fuentes Miguel Damas ◽  
Valero Andrea Fernández ◽  
César María José Picón ◽  
Madueño Francisco José Tinahones

2011 ◽  
Vol 165 (2) ◽  
pp. 301-306 ◽  
Author(s):  
Matthias J Betz ◽  
Christoph Degenhart ◽  
Evelyn Fischer ◽  
Anna Pallauf ◽  
Volker Brand ◽  
...  

ObjectiveAdrenal vein sampling (AVS) is considered the gold standard in the differential diagnosis of primary aldosteronism (PA), but success rates vary between centers. We hypothesized that rapid (intraprocedure) cortisol measurement can improve performance in a center with initially low AVS success rate.DesignWe analyzed 46 patients with confirmed PA studied between 2008 and 2010. Forty-seven PA patients studied between 2004 and 2008 identified by retrospective chart review served as controls. All patients were treated at a single tertiary care university hospital.MethodsStarting in 2008, rapid cortisol assays (RCA) were performed in all patients during the AVS procedure. A cortisol gradient of ≥2.0 between adrenal vein and a femoral vein sample was used as success criterion. Up to two repeat samples were drawn if adrenal vein cortisol was below this threshold.ResultsDuring the control period 26 of 47 AVS were successful (55%). After introduction of RCA, 39 out of 46 AVS (85%) were successful (P=0.003). In 21 of the 46 cases (46%) a resampling was necessary. The increase in overall success was due to an increase in successful right AVS (85 vs 62% before introduction of RCA; P=0.02) and a training effect (P=0.024 for trend).ConclusionRCA during AVS are useful in centers with an initially low AVS success rate.


2009 ◽  
Vol 249 (2) ◽  
pp. 318-321 ◽  
Author(s):  
Richard J. Auchus ◽  
Christina Michaelis ◽  
Frank H. Wians ◽  
Bart L. Dolmatch ◽  
Shellie C. Josephs ◽  
...  

2020 ◽  
Author(s):  
Jiebo Wang ◽  
Liangcheng Zhang ◽  
Zisong Zhao ◽  
Zhongmeng Lai ◽  
Qijian Huang ◽  
...  

Abstract Background: Given the low first-pass success rate of the conventional short-axis (SAX) or long-axis (LAX) approach, ultrasound-guided radial artery cannulation in adults with radial artery diameters less than 2.2 mm may still be challenging. In this study, we compare the efficacy of modified long-axis in-plane(M-LAIP) versus short-axis out-of-plane (SAOP) or conventional palpation(C-P) approaches for ultrasound-guided radial artery cannulation.Methods: This was a prospective, randomized and controlled trial, conducted from 1 July 2018 to 24 November 2018. A total of 201 patients (age 18 to 85 years, the diameter of the radial artery less 2.2 mm) were included. All patients were randomized 1:1:1 to the M-LAIP, SAOP or conventional palpation (C-P) approach. The primary outcome was the cannulation success rate. Secondary outcomes included first location time and cannulation time, number of attempts. The Chi-square (χ2) test was used to compare categorical data between 3 groups.Results: The cannulation success rate was significantly higher in the M-LAIP group than in the SAOP or C-P groups (first success rate: 80.3% vs 53.8% or 33.8%; p < 0.001; total success rate: 93.9% vs 78.5% or 50.8%; p < 0.001). First location time (seconds) was significantly longer in the M-LAIP group (31(28-35[12-44])) than in the SAOP (15(14-17[10-21]); p < 0.001) and C-P groups (12(8-13.5 [6-37]). However, the cannulation time (seconds) in the M-LAIP group (29(24-45[16-313])) was significantly shorter than that in the SAOP (45(28.5-135.5[14-346]); p = 0.002) and the C-P groups (138(27-308[12-363]); p < 0.001). The number of attempts was lower in the M-LAIP group compared with SAOP or C-P group (1.29±0.63 vs 1.8±0.89 or 2.22±0.93, p < 0.001).Conclusions: The use of the M-LAIP approaches significantly improved the success rate of radial artery cannulation in adults with radial artery diameters less than 2.2 mm, compared with that achieved with the use of traditional short-axis out-of-plane approach.Trial registration: ClinicalTrials.gov; No: ChiCTR-IOR-17011474; URL: http: // www. chictr.org. cn/index.aspx. Registered 24 June 2018.


Sign in / Sign up

Export Citation Format

Share Document