Objective: This study was to develop and validate a liquid chromatography–tandem mass spectrometry (LC–MS/MS) for the quantification of lenvatinib (LT) in human plasma.Methods: A simple, sensitive and specific LC–MS/MS method was developed for quantification of LT in human plasma using LTD4 as internal standard (IS). The analytical method consists of liquid–liquid extraction of plasma sample followed by the determination of LT by a LC–MS/MS. The analyte was separated on a Zorbax Eclipse XDB-C18 (150×4.6 mm, 5 μ) column with an isocratic mobile phase of acetontrile:0.1% formic acid (80:20 v/v) at a flow rate of 0.6 mL/minutes. The protonated ions were formed by a turbolon spray in a positive mode were used to detect analyte and IS. The MS/MS detection was made by monitoring the fragmentation of m/z 427.10→370.10 for LT and m/z 430.30→370.10 for IS on a MS.Result: The method was validated with the correlation coefficients of (r2) ≥0.995 over a linear concentration range of 10.20-501.60 pg/mL. This method demonstrated intra- and inter-day precision within 1.06-2.42% and 0.03-0.55% and accuracy within 95.64-100.08% and 97.16-100.07%.Conclusion: This method is suitable and convenient to pharmacokinetics and bioavailability studies for estimation of LT in biological samples by LC–MS/MS.

2018 ◽  
Vol 25 (4) ◽  
pp. 372-380 ◽  
Author(s):  
Sireesha Dodda ◽  
Ajitha Makula ◽  
Srinivasa R Polagani ◽  
Raj N Kandhagatla

A method for bioanalysis of pentoxifylline in human plasma was developed using liquid chromatography–tandem mass spectrometry, which is simple, specific, and sensitive. Pentoxifylline D5 was used as the internal standard. Employing only 100 µl of human plasma, processing was done with solid-phase extraction technique. The analyte and the internal standard were separated from endogenous components on Ace phenyl column using a mixture of 5 mM ammonium acetate buffer and high performance liquid chromatography grade acetonitrile (60:40, v/v) as mobile phase at a flow rate of 1 ml/min. The linearity of the method was in the range of 3–1200 ng/ml with r2 > 0.99. Positive ion MRM mode was used for the detection of the analyte and the internal standard. The method was validated as per the US Food and Drug Administration guidelines and the results were within the acceptance limits. The proposed method was applied for comparative pharmacokinetic study of pentoxifylline after oral administration of 400 and 600 mg tablets to South Indian male subjects under fed conditions.


Sign in / Sign up

Export Citation Format

Share Document