scholarly journals Regional Conduction Velocity Calculation based on Local Activation Times: A Simulation Study on Clinical Geometries

Author(s):  
Bhawna Verma ◽  
Axel Loewe ◽  
Armin Luik ◽  
Claus Schmitt ◽  
Olaf Doessel
2021 ◽  
Vol 12 ◽  
Author(s):  
Mark Nothstein ◽  
Armin Luik ◽  
Amir Jadidi ◽  
Jorge Sánchez ◽  
Laura A. Unger ◽  
...  

BackgroundRate-varying S1S2 stimulation protocols can be used for restitution studies to characterize atrial substrate, ionic remodeling, and atrial fibrillation risk. Clinical restitution studies with numerous patients create large amounts of these data. Thus, an automated pipeline to evaluate clinically acquired S1S2 stimulation protocol data necessitates consistent, robust, reproducible, and precise evaluation of local activation times, electrogram amplitude, and conduction velocity. Here, we present the CVAR-Seg pipeline, developed focusing on three challenges: (i) No previous knowledge of the stimulation parameters is available, thus, arbitrary protocols are supported. (ii) The pipeline remains robust under different noise conditions. (iii) The pipeline supports segmentation of atrial activities in close temporal proximity to the stimulation artifact, which is challenging due to larger amplitude and slope of the stimulus compared to the atrial activity.Methods and ResultsThe S1 basic cycle length was estimated by time interval detection. Stimulation time windows were segmented by detecting synchronous peaks in different channels surpassing an amplitude threshold and identifying time intervals between detected stimuli. Elimination of the stimulation artifact by a matched filter allowed detection of local activation times in temporal proximity. A non-linear signal energy operator was used to segment periods of atrial activity. Geodesic and Euclidean inter electrode distances allowed approximation of conduction velocity. The automatic segmentation performance of the CVAR-Seg pipeline was evaluated on 37 synthetic datasets with decreasing signal-to-noise ratios. Noise was modeled by reconstructing the frequency spectrum of clinical noise. The pipeline retained a median local activation time error below a single sample (1 ms) for signal-to-noise ratios as low as 0 dB representing a high clinical noise level. As a proof of concept, the pipeline was tested on a CARTO case of a paroxysmal atrial fibrillation patient and yielded plausible restitution curves for conduction speed and amplitude.ConclusionThe proposed openly available CVAR-Seg pipeline promises fast, fully automated, robust, and accurate evaluations of atrial signals even with low signal-to-noise ratios. This is achieved by solving the proximity problem of stimulation and atrial activity to enable standardized evaluation without introducing human bias for large data sets.


PLoS ONE ◽  
2021 ◽  
Vol 16 (10) ◽  
pp. e0258285
Author(s):  
Matthias Lange ◽  
Annie M. Hirahara ◽  
Ravi Ranjan ◽  
Gregory J. Stoddard ◽  
Derek J. Dosdall

Slow conduction areas and conduction block in the atria are considered pro-arrhythmic conditions. Studies examining the size and distribution of slow conduction regions in the context of persistent atrial fibrillation (AF) may help to develop improved therapeutic strategies for patients with AF. In this work, we studied the differences of size and number in slow conduction areas between control and persistent AF goats and the influence of propagation direction on the development of these pathological conduction areas. Epicardial atrial electrical activations from the left atrial roof were optically mapped with physiological pacing cycle lengths and for the shortest captured cycle lengths. The recordings were converted to local activation times and conduction velocity measures. Regions with slow conduction velocity (less than 0 . 2 m s) were identified. The size of the connected regions and the number of non-connected regions were counted for propagation from different orthogonal directions. We found that regions of slow conduction significantly increases in our 15 persistent AF goat recordings in response to premature stimulation (24.4±4.3% increase to 36.6±4.4%, p < 0.001). This increase is driven by an increase of size from (3.70±0.89[mm2] to 6.36±0.91[mm2], p = 0.014) for already existing regions and not by generation of new slow conduction regions (11.6±1.8 vs. 13±1.9, p = 0.242). In 12 control goat recordings, no increase from baseline pacing to premature pacing was found. Similarly, size of the slow conduction areas and the count did not change significantly in control animals.


2018 ◽  
Vol 4 (1) ◽  
pp. 247-250
Author(s):  
Armin Müller ◽  
Ekaterina Kovacheva ◽  
Steffen Schuler ◽  
Olaf Dössel ◽  
Lukas Baron

AbstractThe human heart is an organ of high complexity and hence, very challenging to simulate. To calculate the force developed by the human heart and therefore the tension of the muscle fibers, accurate models are necessary. The force generated by the cardiac muscle has physiologically imposed limits and depends on various characteristics such as the length, strain and the contraction velocity of the cardiomyocytes. Another characteristic is the activation time of each cardiomyocyte, which is a wave and not a static value for all cardiomyocytes. To simulate a physiologically correct excitation, the functionality of the cardiac simulation framework CardioMechanics was extended to incorporate inhomogeneous activation times. The functionality was then used to evaluate the effects of local activation times with two different tension models. The active stress generated by the cardiomyocytes was calculated by (i) an explicit function and (ii) an ode-based model. The results of the simulations showed that the maximum pressure in the left ventricle dropped by 2.3% for the DoubleHill model and by 5.3% for the Lumens model. In the right ventricle the simulations showed similar results. The maximum pressure in both the left and the right atrium increased using both models. Given that the simulation of the inhomogeneously activated cardiomyocytes increases the simulation time when used with the more precise Lumens model, the small drop in maximum pressure seems to be negligible in favor of a simpler simulation model