scholarly journals Influence of the outlet air temperature on the thermohydraulic behaviour of air coolers

2003 ◽  
Vol 57 (4) ◽  
pp. 159-164
Author(s):  
Emila Djordjevic ◽  
Slobodan Serbanovic ◽  
Dejan Milosevic ◽  
Aleksandar Tasic ◽  
Bojan Djordjevic

The determination of the optimal process conditions for the operation of air coolers demands a detailed analysis of their thermohydraulic behaviour on the one hand, and the estimation of the operating costs, on the other. One of the main parameters of the thermohydraulic behaviour of this type of equipment, is the outlet air temperature. The influence of the outlet air temperature on the performance of air coolers (heat transfer coefficient overall heat transfer coefficient, required surface area for heat transfer air-side pressure drop, fan power consumption and sound pressure level) was investigated in this study. All the computations, using AirCooler software [1], were applied to cooling of the process fluid and the condensation of a multicomponent vapour mixture on two industrial devices of known geometries.

Author(s):  
Ahmet Selim Dalkiliç ◽  
Ali Celen ◽  
Mohamed M. Awad ◽  
Somchai Wongwises

Heat exchangers using in-tube condensation have great significance in the refrigeration, automotive and process industries. Effective heat exchangers have been rapidly developed due to the demand for more compact systems, higher energy efficiency, lower material costs and other economic incentives. Enhanced surfaces, displaced enhancement devices, swirl-flow devices and surface tension devices improve the heat transfer coefficients in these heat exchangers. This study is a critical review on the determination of the condensation heat transfer coefficient of pure refrigerants flowing in vertical and horizontal tubes. The authors’ previous publications on this issue, including the experimental, theoretical and numerical analyses are summarized here. The lengths of the vertical and horizontal test sections varied between 0.5 m and 4 m countercurrent flow double-tube heat exchangers with refrigerant flowing in the inner tube and cooling water flowing in the annulus. The measured data are compared to theoretical and numerical predictions based on the solution of the artificial intelligence methods and CFD analyses for the condensation process in the smooth and enhanced tubes. The theoretical solutions are related to the design of double tube heat exchangers in refrigeration, air conditioning and heat pump applications. Detailed information on the in-tube condensation studies of heat transfer coefficient in the literature is given. A genetic algorithm (GA), various artificial neural network models (ANN) such as multilayer perceptron (MLP), radial basis networks (RBFN), generalized regression neural network (GRNN), and adaptive neuro-fuzzy inference system (ANFIS), and various optimization techniques such as unconstrained nonlinear minimization algorithm-Nelder-Mead method (NM), non-linear least squares error method (NLS), and Ansys CFD program are used in the numerical solutions. It is shown that the convective heat transfer coefficient of laminar and turbulent condensing film flows can be predicted by means of theoretical and numerical analyses reasonably well if there is a sufficient amount of reliable experimental data. Regression analysis gave convincing correlations, and the most suitable coefficients of the proposed correlations are depicted as compatible with the large number of experimental data by means of the computational numerical methods.


Author(s):  
D.V. Tarasevych ◽  
◽  
O.V. Bogdan ◽  

When choosing architectural and planning solutions, such climatic factors as air temperature and humidity, having scalar quantities, as well as solar radiation, wind and precipitation having vector characteristics, must be taken into account. The calculated climatic parameters for the design of building enclosing structures, heat loss calculations and heat supply regulation are provided in the current documentation on norms and standards. The practical exploitation of various buildings demonstrates that in terms of initial climatic data, the choice of design parameters is not always efficiently justified; hence, the influence of the environment on the heating regime of the structures is insufficient in the estimations and sometimes erroneous. The wind is one of such climatic parameters. Its velocity and repeatability impact the heat exchange of the building structure with the environment as well as the alteration in temperature regime. The wind current towards the building creates additional pressure on the facade of the construction from the wind side direction. This leads, firstly, to air infiltration via the enclosing structures, and secondly, to the rise of heat exchange from the outer surface of the wall on the windward side. Based on estimated and analytical research, the values of the change in wind velocity depending on the altitude were analyzed, and its influence on the heat loss during heating of multi-storey buildings was assessed. The alterations in the wind velocity depending on the altitude were analyzed in the conditions of dense (urban) and broad construction. Besides, the authors presented the dependence of the convective component of the heat transfer coefficient of the outer surface of the structure on the values of the wind velocity. Based on the performed and presented calculations, it can be noticed that the heat transfer of the external structure will be much higher for multi-storey buildings than for mid-rise constructions. Thus, the convective component of the heat transfer coefficient of the outer surface rises by 36 % when the wind velocity increases from 5 m/s to 7 m/s. If not taking into consideration this dependence in the design, it can significantly influence the estimation of heat loss and energy efficiency of buildings, especially when it is about the increased percentage of facades glazing. The authors of the article assessed the heat loss for heating the windward and leeward facades at average values of the outside air temperature during the heating season in Ukraine. Hence, for constructions higher than 70 m with a calculated wind velocity of 5 m/s, heat losses increase from 10 % to 19 %. Such great difference in heat loss between the windward and leeward walls of the building requires increased thermal protection from the prevailing winter winds. Therefore, when designing multi-storey buildings, it is necessary to take into account changes in wind velocity according to the altitude. The obtained results can be useful both for choosing architectural and planning solutions, like the materials for external enclosing structures and for the objective assessment of the wind protection degree of individual buildings and territories.