The Magnitude of the Postural Challenge Impacts on the Exponential Decay of the Baroreflex Impulse Response

Author(s):  
Alberto Porta ◽  
Francesca Gelpi ◽  
Vlasta Bari ◽  
Beatrice Cairo ◽  
Beatrice De Maria ◽  
...  
Geophysics ◽  
2012 ◽  
Vol 77 (4) ◽  
pp. WB137-WB148 ◽  
Author(s):  
Michael W. Asten ◽  
Andrew C. Duncan

The use of simple models for decay of conductive targets under conductive overburden and for the decay of magnetically permeable conductive steel objects allows quantitative consideration of the advantages of the use of magnetic-field detectors in time-domain electromagnetic (TEM) measurements, or more generally, the advantage of step response over impulse response TEM systems. We identified eight advantages of the step response versus impulse-response systems. The first two advantages relate to the inductive limit (early time) decay behavior, in which a target response amplitude is largely dependent on geometrical rather than conductivity parameters. Five further advantages occur when measuring response of a target in a conductive host or under conductive overburden; the maximum target-to-overburden response occurs 25%–30% earlier in time, the earliest target detection time occurs a factor 2–4 earlier, and the amplitude advantage of target-to-overburden response is a factor in the range of 1–10 for the step versus impulse-response systems, respectively. These advantages agree quantitatively with field observations on a chalcopyrite orebody under conductive cover. We used a model response for a conductive permeable sphere to derive mathematically consistent approximations for the power-law and exponential decay behaviors for step and impulse responses of metal objects, from which the onset of late-time exponential decay of EM responses of unexploded ordnance occurs about a factor of two earlier in time for the step response. This earlier-time transition together with the higher signal-to-noise ratio available from the step-response measurement makes measurement of the fundamental time-constant of unexploded ordnance (UXO) possible for medium and large UXO where the time constant is in the range of tens of milliseconds. This time-constant thus becomes accessible as an additional parameter for UXO characterization and discrimination.


1988 ◽  
Vol 42 (3) ◽  
pp. 406-410 ◽  
Author(s):  
M. F. Quinn ◽  
S. Joubian ◽  
F. Al-Bahrani ◽  
S. Al-Aruri ◽  
Oussama Alameddine

A simple deconvolution procedure using FT was developed for determining the average lifetime of samples excited by a nitrogen laser pumped dye laser operating at 428 nm. To overcome the noise limitations imposed by including higher frequency harmonics in the analysis, we used an alternative approach. This approach relied on taking the Fourier transform at 21 subharmonic frequencies and using an appropriate weighting procedure in the calculation of amplitude and lifetime of the sample impulse response. A single exponential decay was assumed.


2007 ◽  
Vol 14 (4) ◽  
pp. 263-266 ◽  
Author(s):  
Yonggang Zhang ◽  
Jonathon A. Chambers ◽  
Saeid Sanei ◽  
Paul Kendrick ◽  
Trevor J. Cox

1991 ◽  
Vol 113 (2) ◽  
pp. 315-316 ◽  
Author(s):  
C. R. MacCluer

The magnitude of the impulse response of a strictly proper stable rational plant at time t is estimated to be of order 0(1/t) where the implied constant is explicitly given in terms of the spectral energy and the real parts of the zeros and poles. When exact location of poles and zeros is uncertain, this estimate can usefully replace the actual but uncertain exponential decay.


2018 ◽  
Vol 138 (3) ◽  
pp. 242-248 ◽  
Author(s):  
Shuji Sato ◽  
Seisuke Nishimura ◽  
Hiroyuki Shimizu ◽  
Hisatoshi Ikeda

Sign in / Sign up

Export Citation Format

Share Document