Self-adaptive resonance frequency tracking for digital notch-filter-based active damping in LCL-filter-based active power filters

Author(s):  
S. Bosch ◽  
D. Lebsanft ◽  
H. Steinhart
Energies ◽  
2019 ◽  
Vol 12 (23) ◽  
pp. 4493
Author(s):  
Tadeusz Platek

This article provides formulae to determine the root mean square (rms) value of a capacitor current in an inductive-capacitive-inductive (LCL) filter used in a parallel active power filter (PAPF) circuit. The article presents an analysis of three components of the capacitor current: a component forced by the usually distorted voltage of the grid; a component forced by the nonlinear load current harmonics and harmonics in the output current of the PAPF that compensates them (a novel aspect presented in this document); and a component forced by the inverters of the PAPF containing carrier and sideband harmonics. The article also presents formulae for determining the rms value of current harmonics in dc-link capacitors forced by the ripple of the ac output current without load of the filter inverters (also novel to this document). The results of the analysis have been confirmed by simulation and experimental research of a commercial active filter consisting of two parallel interleaved voltage inverters. Elements of the LCL filter of the PAPF have been selected according to dependencies available in scientific and technical literature. In addition, the formulae presented in the article are used to verify the correctness of selection of capacitors from the point of view of their catalogue acceptable rms value of capacitor current.


2018 ◽  
Vol 1 (1) ◽  
pp. 54-66
Author(s):  
Rakan Khalil Antar ◽  
Basil Mohammed Saied ◽  
Rafid Ahmed Khalil

A new control strategy for active power filters is proposed, modeled and implemented in order to improve the power quality of a line commutated converter High voltage DC link. The ability of reactive power and harmonics reductions are generally met by using passive and active power filters. In this paper, modified active power filter with a modified harmonics pulse width modulation algorithm is used to minimize the source harmonics and force the AC supply current to be in the same phase with AC voltage source at both sending and receiving sides of a line commutated converter high voltage DC link. Therefore, it is considered as power factor corrector and harmonics eliminator with random variations in the load current. The modified harmonics pulse width modulation algorithm is applicable for active power filter based on a three-phase five-level and seven-level cascaded H-bridge voltage source inverter. Simulation results show that the suggested modified multilevel active power filters improve total harmonics distortion of both voltage and current with almost unity effective power factor at both AC sides of high voltage DC link. Therefore, modified active power filter is an effective tool for power quality improvement and preferable for line commutated converter high voltage DC link at different load conditions.


Sign in / Sign up

Export Citation Format

Share Document