Water Level Control of Flash Chamber in a Spray Flash Desalination System with Valve Dynamics and Flow Rate Limitation

Author(s):  
Yoshitaka Matsuda ◽  
Ryoichi Sakai ◽  
Takenao Sugi ◽  
Satoru Goto ◽  
Takeshi Yasunaga ◽  
...  
2019 ◽  
Vol 35 (5) ◽  
pp. 745-749
Author(s):  
L. E. Christianson ◽  
R. D. Christianson ◽  
A. E. Lipka ◽  
S. Bailey ◽  
J. Chandrasoma ◽  
...  

Abstract. Dependable flow rate measurements are necessary to calculate flow volumes and resulting nutrient loads from subsurface drainage systems and associated conservation practices. The objectives of this study were (1) to develop appropriate weir equations for a new stainless steel-edged 45° V-notch weir developed for AgriDrain inline water level control structures and (2) to determine if the equation was independent of flow depth in the structure. Weirs for 15 cm (6 in.) and 25 cm (10 in.) inline water level control structures were placed at three heights in each structure: at the base, 48 cm from the base, or 97 cm from the base, and the height of the nappe above the weir crest was recorded over a range of flow rates. The resulting data were fitted to equations of the form Q = aHb where Q is the flow rate, H is the height of the nappe above the weir crest, and a and b are fitted parameters. There were no significant differences in the fitted parameters across the two structure sizes or across the three weir placements. The fitted equation for these new stainless steel-edged V-notch weirs was Q = 0.011H2.28 with Q in liters per second and H in centimeters, and Q = 1.44H2.28, with Q in gallons per minute and H in inches. These equations can be used for measuring flow through AgriDrain in-line structures, although in-house weir calibration is highly recommended for specific applications, when possible. Keywords: Drainage, Flow monitoring, Subsurface drainage, V-notch weir, Weir calibration.


Water ◽  
2019 ◽  
Vol 11 (12) ◽  
pp. 2576
Author(s):  
Janusz Kubrak ◽  
Elżbieta Kubrak ◽  
Edmund Kaca ◽  
Adam Kiczko ◽  
Michał Kubrak

This article introduces a flow controller for an upstream water head designed for pipe culverts used in drainage ditches or wells. The regulator is applicable to water flow rates in the range of Qmin < Q < Qmax and the water depth H0, exceeding which causes the gate to open. Qmin flow denotes the minimum flow rate that allows water to accumulate upstream of the controller. Above the maximum flow rate Qmax, the gate remains in the open position. In the present study, the position of the regulator’s gate axis was related to the water depth H0 in front of the device. Derived dependencies were verified in hydraulic experiments. The results confirmed the regulator’s usefulness for controlling the water level.


2002 ◽  
Vol 122 (6) ◽  
pp. 989-994
Author(s):  
Shinichiro Endo ◽  
Masami Konishi ◽  
Hirosuke Imabayashi ◽  
Hayami Sugiyama

Author(s):  
Xin Tian ◽  
Boran Ekin Aydin ◽  
Rudy R. Negenborn ◽  
Nick van de Giesen ◽  
José María Maestre

Sign in / Sign up

Export Citation Format

Share Document