Evaluation of human upper limb motion comfort based on motion capture system

Author(s):  
Tao Qing ◽  
Li Zhao-Bo ◽  
Kang Jinsheng
Sensors ◽  
2020 ◽  
Vol 20 (21) ◽  
pp. 6379 ◽  
Author(s):  
Chang Liu ◽  
Hongbo Liang ◽  
Naoya Ueda ◽  
Peirang Li ◽  
Yasutaka Fujimoto ◽  
...  

A power-assisted exoskeleton should be capable of reducing the burden on the wearer’s body or rendering his or her work improved and efficient. More specifically, the exoskeleton should be easy to wear, be simple to use, and provide power assistance without hindering the wearer’s movement. Therefore, it is necessary to evaluate the backdrivability, range of motion, and power-assist capability of such an exoskeleton. This evaluation identifies the pros and cons of the exoskeleton, and it serves as the basis for its subsequent development. In this study, a lightweight upper-limb power-assisted exoskeleton with high backdrivability was developed. Moreover, a motion capture system was adopted to measure and analyze the workspace of the wearer’s upper limb after the exoskeleton was worn. The results were used to evaluate the exoskeleton’s ability to support the wearer’s movement. Furthermore, a small and compact three-axis force sensor was used for power assistance, and the effect of the power assistance was evaluated by means of measuring the wearer’s surface electromyography, force, and joint angle signals. Overall, the study showed that the exoskeleton could achieve power assistance and did not affect the wearer’s movements.


Healthcare ◽  
2021 ◽  
Vol 9 (8) ◽  
pp. 1076
Author(s):  
Laisi Cai ◽  
Dongwei Liu ◽  
Ye Ma

Low-cost, portable, and easy-to-use Kinect-based systems achieved great popularity in out-of-the-lab motion analysis. The placement of a Kinect sensor significantly influences the accuracy in measuring kinematic parameters for dynamics tasks. We conducted an experiment to investigate the impact of sensor placement on the accuracy of upper limb kinematics during a typical upper limb functional task, the drinking task. Using a 3D motion capture system as the golden standard, we tested twenty-one Kinect positions with three different distances and seven orientations. Upper limb joint angles, including shoulder flexion/extension, shoulder adduction/abduction, shoulder internal/external rotation, and elbow flexion/extension angles, are calculated via our developed Kinect kinematic model and the UWA kinematic model for both the Kinect-based system and the 3D motion capture system. We extracted the angles at the point of the target achieved (PTA). The mean-absolute-error (MEA) with the standard represents the Kinect-based system’s performance. We conducted a two-way repeated measure ANOVA to explore the impacts of distance and orientation on the MEAs for all upper limb angles. There is a significant main effect for orientation. The main effects for distance and the interaction effects do not reach statistical significance. The post hoc test using LSD test for orientation shows that the effect of orientation is joint-dependent and plane-dependent. For a complex task (e.g., drinking), which involves body occlusions, placing a Kinect sensor right in front of a subject is not a good choice. We suggest that place a Kinect sensor at the contralateral side of a subject with the orientation around 30∘ to 45∘ for upper limb functional tasks. For all kinds of dynamic tasks, we put forward the following recommendations for the placement of a Kinect sensor. First, set an optimal sensor position for capture, making sure that all investigated joints are visible during the whole task. Second, sensor placement should avoid body occlusion at the maximum extension. Third, if an optimal location cannot be achieved in an out-of-the-lab environment, researchers could put the Kinect sensor at an optimal orientation by trading off the factor of distance. Last, for those need to assess functions of both limbs, the users can relocate the sensor and re-evaluate the functions of the other side once they finish evaluating functions of one side of a subject.


DYNA ◽  
2015 ◽  
Vol 82 (189) ◽  
pp. 68-75 ◽  
Author(s):  
Mauro Callejas Cuervo ◽  
Gloria M. Díaz ◽  
Andrés Felipe Ruíz-Olaya

2015 ◽  
Vol 24 (40) ◽  
pp. 41
Author(s):  
Mauro Callejas-Cuervo ◽  
Manuel Andrés Vélez-Guerrero ◽  
Andrés Felipe Ruíz-Olaya ◽  
Rafael María Gutiérrez-Salamanca

<p>This article proposes a system for Telerehabilitation of people with motor disorders of the upper limb, by making a literature review about works related with the provision of the physical therapy service with ICT’s use. Likewise, there is a brief description of the modules integrating the system: motion capture system based on inertial sensors and motion capture with camera; joint angle estimator was implemented through Kalman filter; IT app which registers the electronic medical record and finally, the active videogames module.</p>


Sensor Review ◽  
2019 ◽  
Vol 39 (4) ◽  
pp. 504-511 ◽  
Author(s):  
Muhammad Yahya ◽  
Jawad Ali Shah ◽  
Kushsairy Abdul Kadir ◽  
Zulkhairi M. Yusof ◽  
Sheroz Khan ◽  
...  

Purpose Motion capture system (MoCap) has been used in measuring the human body segments in several applications including film special effects, health care, outer-space and under-water navigation systems, sea-water exploration pursuits, human machine interaction and learning software to help teachers of sign language. The purpose of this paper is to help the researchers to select specific MoCap system for various applications and the development of new algorithms related to upper limb motion. Design/methodology/approach This paper provides an overview of different sensors used in MoCap and techniques used for estimating human upper limb motion. Findings The existing MoCaps suffer from several issues depending on the type of MoCap used. These issues include drifting and placement of Inertial sensors, occlusion and jitters in Kinect, noise in electromyography signals and the requirement of a well-structured, calibrated environment and time-consuming task of placing markers in multiple camera systems. Originality/value This paper outlines the issues and challenges in MoCaps for measuring human upper limb motion and provides an overview on the techniques to overcome these issues and challenges.


2018 ◽  
Vol 11 (2) ◽  
pp. 93-99
Author(s):  
Zoltán Lénárt ◽  
Gergely Nagymáté ◽  
Andor Szabó

Author(s):  
Jonathan Kenneth Sinclair ◽  
Lindsay Bottoms

AbstractRecent epidemiological analyses in fencing have shown that injuries and pain linked specifically to fencing training/competition were evident in 92.8% of fencers. Specifically the prevalence of Achilles tendon pathology has increased substantially in recent years, and males have been identified as being at greater risk of Achilles tendon injury compared to their female counterparts. This study aimed to examine gender differences in Achilles tendon loading during the fencing lunge.Achilles tendon load was obtained from eight male and eight female club level epee fencers using a 3D motion capture system and force platform information as they completed simulated lunges. Independent t-tests were performed on the data to determine whether differences existed.The results show that males were associated with significantly greater Achilles tendon loading rates in comparison to females.This suggests that male fencers may be at greater risk from Achilles tendon pathology as a function of fencing training/ competition.


2006 ◽  
Vol 99 (8) ◽  
pp. 08B312 ◽  
Author(s):  
S. Hashi ◽  
M. Toyoda ◽  
M. Ohya ◽  
Y. Okazaki ◽  
S. Yabukami ◽  
...  

2021 ◽  
Vol 11 (13) ◽  
pp. 5865
Author(s):  
Muhammad Ahsan Gull ◽  
Mikkel Thoegersen ◽  
Stefan Hein Bengtson ◽  
Mostafa Mohammadi ◽  
Lotte N. S. Andreasen Struijk ◽  
...  

Wheelchair mounted upper limb exoskeletons offer an alternative way to support disabled individuals in their activities of daily living (ADL). Key challenges in exoskeleton technology include innovative mechanical design and implementation of a control method that can assure a safe and comfortable interaction between the human upper limb and exoskeleton. In this article, we present a mechanical design of a four degrees of freedom (DOF) wheelchair mounted upper limb exoskeleton. The design takes advantage of non-backdrivable mechanism that can hold the output position without energy consumption and provide assistance to the completely paralyzed users. Moreover, a PD-based trajectory tracking control is implemented to enhance the performance of human exoskeleton system for two different tasks. Preliminary results are provided to show the effectiveness and reliability of using the proposed design for physically disabled people.


Sign in / Sign up

Export Citation Format

Share Document