scholarly journals Seismic Performance of Masonry Cross Vaults through Shaking Table Testing on a Scaled Model

2021 ◽  
Author(s):  
N. Bianchini ◽  
N. Mendes ◽  
P. Candeias ◽  
M. Rossi ◽  
C. Calderini ◽  
...  
2010 ◽  
Vol 163-167 ◽  
pp. 1281-1285
Author(s):  
Bin Wang ◽  
Huan Jun Jiang ◽  
Jian Bao Li ◽  
Wen Sheng Lu ◽  
Xi Lin Lu

The reinforced concrete (RC) frame-tube structure considered in the study has two towers with lapping transfer columns. The lapping transfer columns, considering aesthetic requirement in elevation, lead to a complex vertical force transfer system. The large irregularity in elevation, according to Chinese code, necessitates a detailed study. A 1/15-scaled model of the high-rise building was tested on a shaking table to evaluate its seismic performance. The model was subjected to earthquake inputs representing frequent, basic, rare, and extremly rare earthquakes. The results of shaking table test in terms of the global and local responses as well as the dynamic properties are presented. The tests demonstrate that the designed structural system satisfies the pre-defined performance objectives and the lapping transfer columns have good seismic peformance. To better control seismic damages of the building, some suggestions for improving the design of this structure are also put forward at last.


2012 ◽  
Vol 11 (4) ◽  
pp. 1157-1190 ◽  
Author(s):  
Paulo B. Lourenço ◽  
Leonardo Avila ◽  
Graça Vasconcelos ◽  
J.Pedro Pedro Alves ◽  
Nuno Mendes ◽  
...  

2019 ◽  
Vol 2019 ◽  
pp. 1-14
Author(s):  
Xu Duan ◽  
Qi Dong ◽  
Wanjun Ye

Utility tunnel is a kind of underground tunnel structure that carries more than two types of public utility lines, and the utility tunnels built by the prefabricated method have been adopted in many modern cities due to their easy maintenance and environmental protection capabilities. However, knowledge about the seismic performance of the prefabricated utility tunnel and pipelines inside is quite limited. In this paper, a prefabricated utility tunnel newly built in Xi’an, China, is taken as the prototype; a series of shaking table tests are conducted to investigate the seismic performance of the prefabricated utility tunnel in loess foundation, using El Centro earthquake wave as the input loading. Details of the experimental setup focus on the design of the soil container, scaled model (1 : 10), sensor arrangement, and test cases. Dynamic responses including evaluation of boundary effect, the amplification factor of the ground and structure, distribution of soil pressure, characteristics of predominant frequencies, and the damage phenomena are analyzed. Dynamic strain obtained by Fiber Bragg Grating sensors releases the critical positions of the prefabricated utility tunnel during the earthquake. Moreover, the dynamic responses of the pipelines contained in the utility tunnel are also analyzed. From aforementioned results, the seismic performance of the prefabricated utility tunnel has been revealed. The results will provide a reference for the seismic design of prefabricated utility tunnels.


2015 ◽  
Vol 82 ◽  
pp. 186-198 ◽  
Author(s):  
Qing-Hua Han ◽  
Ying Xu ◽  
Yan Lu ◽  
Jie Xu ◽  
Qiu-Hong Zhao

Sign in / Sign up

Export Citation Format

Share Document