scholarly journals Shaking table testing of an existing masonry building: assessment and improvement of the seismic performance

2013 ◽  
Vol 43 (2) ◽  
pp. 247-266 ◽  
Author(s):  
Nuno Mendes ◽  
Paulo B. Lourenço ◽  
Alfredo Campos-Costa
2012 ◽  
Vol 11 (4) ◽  
pp. 1157-1190 ◽  
Author(s):  
Paulo B. Lourenço ◽  
Leonardo Avila ◽  
Graça Vasconcelos ◽  
J.Pedro Pedro Alves ◽  
Nuno Mendes ◽  
...  

2021 ◽  
Author(s):  
N. Bianchini ◽  
N. Mendes ◽  
P. Candeias ◽  
M. Rossi ◽  
C. Calderini ◽  
...  

2011 ◽  
Vol 250-253 ◽  
pp. 1196-1205
Author(s):  
Zhong Fan Chen ◽  
Fei Lu ◽  
Yang Yuan ◽  
Sha Sha Miao

Rowlock cavity wall was widely used in rural house in Southern Jiangsu Province from 1980s to 1990s. As one type of masonry structures, the seismic performance of rowlock cavity wall has rarely been studied on. Based on the report of General Seismic Investigation in Jiangsu Qidong, one 1/2-scale rowlock cavity wall structure was modeled as the existing rural house, and was tested on shaking table in lab of Southeast University. After analyzing the failure state of the model, and examining the structural parameters such as natural frequency, damping ratio, floor acceleration, floor shift, strain and crack of the model in load condition of different earthquake wave and intensity, the seismic performance of rowlock wall structure was assessed. And the seismic capacity of the whole model and each piece of rowlock wall was also analyzed. Based on the mortar strength field inspected in model wall, the seismic capacity of model structure under the action of rarely occurred earthquake of level 6 seismic precautionary intensity was estimated. The result showed that the model structure would collapse under the load condition. Obviously, this can not satisfy the seismic precautionary requirement in Code for Seismic Design of Buildings (GB50011-2001). Therefore, some principal reinforcement suggestions were discussed and proposed for existing rowlock cavity wall buildings. The research result of this paper could provide some theoretical foundation for the Aseismic Residential Project of rural peasant house, and also could be referred to for further research on rowlock cavity wall structures.


2012 ◽  
Vol 588-589 ◽  
pp. 1950-1954
Author(s):  
Hui Su ◽  
Guo Song Han ◽  
Xin Pei Jiang

In order to research the seismic property of masonry building constructed with the construction waste recycled bricks, a four stories building model with 1:3 scale is constructed and tested on the shaking table. Based on the test results, the cracks pattern, displacement response, acceleration response of the building are studied. The failure mechanism of the infill building is investigated. The results show that the construction waste recycled brick is a qualified building material to construct the low rise building.


2010 ◽  
Vol 133-134 ◽  
pp. 635-640 ◽  
Author(s):  
Nuno Mendes ◽  
Paulo B. Lourenço ◽  
A. Campos-Costa

This paper presents a review of the methods for seismic vulnerability assessment, together with an experimental method based on shaking table testing. This method is applied to a Portuguese masonry building typology with stone walls and timber floors, subjected to increasing earthquake damage. Traditional-like materials and techniques are used in the building. The vulnerability curves are presented and the damage indicator is correlated with the crack patterns and EMS 98.


2012 ◽  
Vol 174-177 ◽  
pp. 2012-2015
Author(s):  
Xiao Long Zhou ◽  
Ying Min Li ◽  
Lin Bo Song ◽  
Qian Tan

There are two typical seismic damage characteristics to the masonry building with frame shear wall structure at first two stories, and the lateral stiffness ratio of the third storey to the second storey is one of the key factors mostly affecting the seismic performance of this kind of building. However, some factors are not considered sufficiently in current Chinese seismic codes. According to the theory of performance-based seismic design, the seismic performance of this kind of structure is analyzed in this paper by taking time-history analysis on models which with different storey stiffness ratios. The results show that when the lateral stiffness ratio controlled in a reasonable range, the upper masonry deformation can be ensured in a range of elastic roughly, and the bottom frame can be guaranteed to have sufficient deformation and energy dissipation capacity. Finally, according to the seismic performance characteristics of masonry building with frame shear wall structure at first two stories, especially the characteristics under strong earthquakes, a method of simplified calculation model for the upper masonry is discussed in this paper.


2015 ◽  
Vol 82 ◽  
pp. 186-198 ◽  
Author(s):  
Qing-Hua Han ◽  
Ying Xu ◽  
Yan Lu ◽  
Jie Xu ◽  
Qiu-Hong Zhao

Sign in / Sign up

Export Citation Format

Share Document