Survey of self-reported radiation safety practices among North American veterinary technicians involved in equine radiography using portable x-ray equipment

2021 ◽  
Vol 259 (8) ◽  
pp. 919-926
Author(s):  
Alexandra F. Belotta ◽  
Monique N. Mayer ◽  
Niels K. Koehncke ◽  
James Carmalt ◽  
Fernando P. Freitas ◽  
...  
2018 ◽  
Vol 33 (4) ◽  
pp. e38-e39
Author(s):  
Collins Melissa ◽  
Corridon Emily ◽  
Reene Samantha

2021 ◽  
pp. rapm-2020-102002
Author(s):  
David Anthony Provenzano ◽  
Samuel Ambrose Florentino ◽  
Jason S Kilgore ◽  
Jose De Andres ◽  
B Todd Sitzman ◽  
...  

IntroductionInterventional pain procedures have increased in complexity, often requiring longer radiation exposure times and subsequently higher doses. The practicing physician requires an in-depth knowledge and evidence-based knowledge of radiation safety to limit the health risks to themselves, patients and healthcare staff. The objective of this study was to examine current radiation safety practices and knowledge among interventional pain physicians and compare them to evidence-based recommendations.Materials and methodsA 49-question survey was developed based on an extensive review of national and international guidelines on radiation safety. The survey was web-based and distributed through the following professional organizations: Association of Pain Program Directors, American Academy of Pain Medicine, American Society of Regional Anesthesia and Pain Medicine, European Society of Regional Anesthesia and Pain Therapy, International Neuromodulation Society, and North American Neuromodulation Society. Responses to radiation safety practices and knowledge questions were evaluated and compared with evidence-based recommendations. An exploratory data analysis examined associations with radiation safety training/education, geographical location, practice type, self-perceived understanding, and fellowship experience.ResultsOf 708 responding physicians, 93% reported concern over the health effects of radiation, while only 63% had ever received radiation safety training/education. Overall, ≥80% physician compliance with evidence-based radiation safety practice recommendations was demonstrated for only 2/15 survey questions. Physician knowledge of radiation safety principles was low, with 0/10 survey questions having correct response rates ≥80%.ConclusionWe have identified deficiencies in the implementation of evidence-based practices and knowledge gaps in radiation safety. Further education and training are warranted for both fellowship training and postgraduate medical practice. The substantial gaps identified should be addressed to better protect physicians, staff and patients from unnecessary exposure to ionizing radiation during interventional pain procedures.


2020 ◽  
Vol 43 (3) ◽  
pp. 765-779
Author(s):  
Zoe Brady ◽  
Heather Scoullar ◽  
Ben Grinsted ◽  
Kyle Ewert ◽  
Helen Kavnoudias ◽  
...  

2008 ◽  
Vol 42 (5) ◽  
pp. 247-248
Author(s):  
N. N. Blinov ◽  
E. B. Kozlovskii
Keyword(s):  

2006 ◽  
Vol 21 (4) ◽  
pp. 320-322 ◽  
Author(s):  
P. Ch. Sahu ◽  
N. R. Sanjay Kumar ◽  
N. V. Chandra Shekar ◽  
N. Subramanian

An incident beam X-ray collimator for Mao-Bell type diamond anvil cell (DAC) has been developed. Alignment of the collimator is carried out in situ while viewing the image of the collimated X-ray spot formed on a thin layer of fluorescent material spread on the diamond anvil culets with the help of a microscope. Special precaution has been taken to meet the radiation safety requirements during alignment and routine use. This collimator is of immense help for laboratory based high pressure X-ray diffraction experiments.


Sign in / Sign up

Export Citation Format

Share Document