Eye Movements Simultaneously Recorded by Electrooculographic and Photoelectric Methods

1979 ◽  
Vol 48 (2) ◽  
pp. 619-624 ◽  
Author(s):  
Jin Ong ◽  
Gene A. Harman

Three types of eye movements, saccadic, reading, and pursuit, were recorded from 6 college subjects, two in each by the electrooculographic and photoelectric methods simultaneously. A deviation index (DI), which is the standard deviation divided by the mean, was devised to compare the precision of recording amplitude deflection, and a proportion index (PI), which is M1 divided by M2, was devised to compare the mean amplitude indirectly between these two methods. Results showed that the proportion indexes of three types of eye movements were comparable, and the mean index of 0.54 indicated that the amplification in the electrooculographic method was about half as much as that in the photoelectric. The mean deviation index of 0.132 vs 0.135 was, again, comparable, meaning that these two methods of recording amplitude deflections are of about the same degree of magnitude and precision. Certain qualitative differences regarding the amplitude and velocity peak deflection between these two methods were also noted.

2019 ◽  
Vol 2019 ◽  
pp. 1-5
Author(s):  
Cristiana Valente ◽  
Elisa D’Alessandro ◽  
Michele Iester

Aim. To evaluate the agreement between different methods in detection of glaucomatous visual field progression using two classification-based methods and four statistical approaches based on trend analysis. Methods. This is a retrospective and longitudinal study. Twenty Caucasian patients (mean age 73.8 ± 13.43 years) with open-angle glaucoma were recruited in the study. Each visual field was assessed by Humphrey Field Analyzer, program SITA standard 30-2 or 24-2 (Carl Zeiss Meditec, Inc., Dublin, CA). Full threshold strategy was also accepted for baseline tests. Progression was analyzed by using Hodapp–Parrish–Anderson classification and the Advanced Glaucoma Intervention Study visual field defect score. For the statistical analysis, linear regression (r2) was calculated for mean deviation (MD), pattern standard deviation (PSD), and visual field index (VFI), and when it was significant, each series of visual field was considered progressive. We also used Progressor to look for a significant progression of each visual field series. The agreement between methods, based on statistical analysis and classification, was evaluated using a weighted kappa statistic. Results. Thirty-eight visual field series were analyzed. The mean follow-up time was 6.2 ± 1.53 years (mean ± standard deviation). At baseline, the mean MD was −7.34 ± 7.18 dB; at the end of the follow-up, the mean MD was −9.25 ± 8.65 dB; this difference was statistically significant (p<0.001). The agreement to detect progression was fair between all methods based on statistical analysis and classification except for PSD r2. A substantial agreement (κ = 0.698 ± 0.126) was found between MD r2 and VFI r2. With the use of all the statistical analysis, there was a better time-saving. Conclusions. The best agreement to detect progression was found between MD r2 and VFI r2. VFI r2 showed the best agreement with all the other methods. GPA2 can help ophthalmologists to detect glaucoma progression and to help in treatment decisions. PSD r2 was the worse method to detect progression.


2020 ◽  
Vol 2020 ◽  
pp. 1-9
Author(s):  
Harsh Kumar ◽  
Mithun Thulasidas

Purpose. To compare visual field results obtained using Melbourne Rapid Fields (MRF) iPad-based perimeter software and Humphrey Field Analyzer (HFA) 24-2 Swedish Interactive Threshold Algorithm (SITA) standard program in glaucoma patients. Design. A cross-sectional observational study. Methods. In this single-centre study involving patients diagnosed with glaucoma, the perimetric outcomes of MRF were compared against those returned from the HFA 24-2 SITA standard. Outcomes included mean deviation (MD), pattern standard deviation (PSD), visual field index (VFI)/visual capacity (VC), foveal threshold, test time, number of points depressed at P<5% on PSD probability plot, and glaucoma hemifield test/color coded indicator. Results. The study included 28 eyes of 28 glaucoma patients. Mean (standard deviation) test times were 342.07 (56.70) seconds for MRF and 375.11 (88.95) for HFA 24-2 SITA standard P=0.046. Mean MD was significantly lower for MRF (Δ = 3.09, P<0.001), and mean PSD was significantly higher for MRF (Δ = 1.40, P=0.005) compared with HFA. The mean foveal threshold for the MRF was significantly lower than the mean HFA foveal threshold ((Δ = 9.25, P<0.001). The number of points depressed at P<5% on the PSD probability plot was significantly less for MRF P<0.001. Other perimetric outcomes showed no significant differences between both. Bland–Altman plots showed that considerable variability existed between the programs. Conclusion. MRF is a good cost-effective, time-saving, user-friendly tool for monitoring visual fields in settings where access to traditional perimetry is limited. The lack of Internet strength in rural areas and questionable detection of early cases may be two points in MRF fields requiring an upgrade.


2011 ◽  
Vol 4 (7) ◽  
pp. 1541-1550 ◽  
Author(s):  
F. Zus ◽  
G. Beyerle ◽  
S. Heise ◽  
T. Schmidt ◽  
J. Wickert ◽  
...  

Abstract. Results from GRAS (GNSS Receiver for Atmospheric Sounding) RO (Radio Occultation) data recorded in RS (Raw Sampling) mode processed at the GFZ (German Research Centre for Geoscience) Potsdam are presented. The experimental processing software POCS-X includes FSI (Full Spectrum Inversion) in order to cope with multi-path regions and enables in connection with RS data to retrieve atmospheric refractivity profiles down to the Earths surface. Radio occultation events observed between 30 September and 30 October 2007 are processed and the retrievals are validated against co-located ECMWF (European Centre for Medium-Range Weather Forecasts) profiles. The intercomparison indicates good quality of the retrieved profiles. In the altitude range 8 to 25 km the standard deviation is below 1 %. The mean deviation in this altitude range tends to be negative. At 30 km the negative bias reaches about −0.4 %. Below 8 km the standard deviation increases, reaching 2.5 % at 2 km. Below 2 km the mean deviation tends to be negative, reaching −1.9 % close to the ground. The negative bias mainly stems from the tropical lower troposphere; there, the negative bias reaches −3 %. The tropospheric penetration depth obtained from RS data shows a vast improvement compared to the tropospheric penetration depth typically obtained from CL (Closed Loop) data; 50 % of all retrieved profiles reach 720 m.


2019 ◽  
Vol 3 ◽  
pp. 1-10
Author(s):  
Jyotirmoy Sarkar ◽  
Mamunur Rashid

Background: Sarkar and Rashid (2016a) introduced a geometric way to visualize the mean based on either the empirical cumulative distribution function of raw data, or the cumulative histogram of tabular data. Objective: Here, we extend the geometric method to visualize measures of spread such as the mean deviation, the root mean squared deviation and the standard deviation of similar data. Materials and Methods: We utilized elementary high school geometric method and the graph of a quadratic transformation. Results: We obtain concrete depictions of various measures of spread. Conclusion: We anticipate such visualizations will help readers understand, distinguish and remember these concepts.


1947 ◽  
Vol 7 (01) ◽  
pp. 23-28
Author(s):  
R. E. Beard

The standard deviation of the distribution of sickness is a statistic that appears to have been ignored by British Actuaries, with the exception of Sir G. F. Hardy who derived an approximation in his well-known Essay (J.I.A.Vol. XXVII, 1889, p. 245). By considering the graduated results of the A.O.F. Experience 1871–75 he concluded that the mean deviation of expected sickness was approximately 2√(expected weeks of sickness).This note has arisen from some investigations being made into the statistics of non-life business, from which it appeared that the results obtained could be used to place the derivation of the standard deviation of expected sickness on a more satisfactory basis, and it is being put forward in the hope that some member with access to the necessary statistics will be able to make a more detailed study of this problem.


2013 ◽  
Vol 2013 ◽  
pp. 1-7 ◽  
Author(s):  
Isabel Pinilla ◽  
Antonio Ferreras ◽  
Miriam Idoipe ◽  
Ana I. Sanchez-Cano ◽  
Diana Perez-Garcia ◽  
...  

Purpose. To evaluate the ability of frequency-doubling technology (FDT) perimetry in detecting visual field defects in young adults with type I diabetes prior to retinopathy or with minor retinovascular changes.Methods. This comparative cross-sectional study included 30 healthy subjects and 73 age-matched patients with type I diabetes mellitus. All subjects underwent a full ocular examination including an FDT with the threshold C-20-5 strategy. Only one eye per subject was randomly included in the statistical analysis. FDT results and time to perform the test were compared between the groups.Results. The mean age was 27.1 years in the control group and 26.6 years in the diabetic group (P=0.875). The mean period from the onset of diabetes was12.6±6.7years, while minimal retinovascular changes were observed in 18 eyes. Mean deviation of FDT did not differ between the groups. Although global indices of FDT were within normal limits, pattern standard deviation of FDT was higher in the diabetic group (P=0.035). The area under the receiver operating characteristic curve was 0.647 for pattern standard deviation of FDT (standard error = 0.052;P=0.017).Conclusion. FDT can detect retinal dysfunctions in diabetic patients prior to the onset of significant vascular complications.


2021 ◽  
Author(s):  
Benedict Troon

Measure of dispersion is an important statistical tool used to illustrate the distribution of datasets.The use of this measure has allowed researchers to define the distribution of various datasets especially the measures of dispersion from the mean. Researchers have been able to develop measures of dispersion from the mean such as mean deviation, mean absolute deviation, variance and standard deviation. Studies have shown that standard deviation is currently the most efficient measure of variation about the mean and the most popularly used measure of variation about the mean around the world because of its fewer shortcomings. However, studies have also established that standard deviation is not 100% efficient because the measure is affected by outlier in thedatasets and it also assumes symmetry of datasets when estimating the average deviation about the mean a factor that makes it to be responsive to skewed datasets hence giving results which are biased for such datasets. The aim of this study is to make a comparative analysis of the precision of the geometric measure of variation and standard deviation in estimating the average variationabout the mean for various datasets. The study used paired t-test to test the difference in estimates given by the two measures and four measures of efficiency (coefficient of variation, relative efficiency, mean squared error and bias) to assess the efficiency of the measure. The results determined that the estimates of geometric measure were significantly smaller than those of standard deviation and that the geometric measure was more efficient in estimating the average deviation for geometric, skewed and peaked datasets. In conclusion, the geometric measure was not affected by outliers and skewed datasets, hence it was more precise than standard deviation.


Sign in / Sign up

Export Citation Format

Share Document