scholarly journals Simultaneous chiral separation and determination of carvedilol and 5′-hydroxyphenyl carvedilol enantiomers from human urine by high performance liquid chromatography coupled with fluorescent detection

2013 ◽  
Vol 11 (12) ◽  
pp. 2076-2087 ◽  
Author(s):  
Sylwia Magiera ◽  
Weronika Adolf ◽  
Irena Baranowska

AbstractA sensitive and specific high performance liquid chromatography coupled with fluorescent detection (HPLC-FL) and tandem mass spectrometry detection (HPLC-MS/MS) methods for separation and determination of carvedilol (CAR) enantiomers and 5′-hydroxyphenyl carvedilol (5′-HCAR) enantiomers has been developed and validated. The analysed compounds were extracted from human urine by solid phase extraction. Good enantioseparation of the studied enantiomers was achieved on CHIRALCEL® OD-RH column using 0.05% trifluoroacetic acid and 0.05% diethylamine in water and acetonitrile in a gradient elution. The mass spectrometric data were acquired using the multiple reaction monitoring mode by positive electrospray ionisation. The method was validated over the concentration range from 25.0 ng mL−1 to 200 ng mL−1 for the analysed compounds. The limit of quantification varied from 14.2 ng mL−1 to 24.2 ng mL−1. Both the repeatability and inter-day precisions were below 10.0%, and the accuracy varied from −13.2% to 3.77%. The extraction recoveries ranged from 79.2% to 108%. The present paper reports the method for the simultaneous determination of CAR enantiomers and their metabolite enantiomers (5′-HCAR) in human urine samples. This newly developed method was successfully used to analyse the aforementioned analytes in human urine samples obtained from patients suffering from cardiovascular disease.

Author(s):  
Tomasz Tuzimski ◽  
Szymon Szubartowski

In this study, we propose a simple, cost-effective, and sensitive high-performance liquid chromatography method with fluorescence detection (HPLC-FLD) for the simultaneous determination of the three bisphenols (BPs): bisphenol A bis (2,3-dihydroxypropyl) ether (BADGE 2H2O), bisphenol F (BPF), and bisphenol E (BPE) in human urine samples. The dispersive solid phase extraction (d-SPE) coupled with solid phase extraction (SPE) procedure performed well for the analytes with recoveries in the range of 74.3–86.5% and relative standard deviations (RSD%) less than 10%. The limits of quantification (LOQs) for all investigated analytes were in the range of 11.42–22.35 ng mL−1. The method was validated at three concentration levels (1 × LOQ, 1.5 × LOQ, and 3 LOQ). During the bisphenols HPLC-FLD analysis, from 6 min a reinforcement (10 or 12) was used, therefore analytes might be identified in the small volume human urine samples. The results demonstrated clearly that the approach developed provides reliable, simple, and rapid quantification and identification of three bisphenols in a urine matrix and could be used for monitoring these analytes.


Sign in / Sign up

Export Citation Format

Share Document