scholarly journals Determination of Chlorotetracycline and Doxycycline in Medicated Feedingstuffs by Liquid Chromatography

2012 ◽  
Vol 56 (3) ◽  
pp. 329-333 ◽  
Author(s):  
Ewelina Patyra ◽  
Ewelina Kowalczyk ◽  
Krzysztof Kwiatek

Abstract High performance liquid chromatography method with diode array detection (HPLC-DAD) was developed and optimised for the determination of tetracyclines (TCs) in medicated feedingstuffs. The extraction of the analyte from feedingstuffs was performed with Na2EDTA-McIlvaine buffer (pH 2.5 and pH 4). The extracts were cleaned up by solid phase extraction using octadecyl cartridges (C18). The samples were dried up and redissolved in the mixture of oxalic acid and methanol. Separation was performed on reserved phase column (Phenomenex C18, 250 x 4.6 mm, 5 μm) by multistep gradient elution, which provided better chromatographic separation. The analysis was performed at a wavelength of 390 nm. Validation study of the method revealed that all obtained calibration curves showed good linearity R= 0.9985 for doxycycline (DC) and R= 0.9981 for chlorotetracycline (CTC) over the range of 25-2,000 mg/kg. The analytical procedure was successfully adapted for quantitative determination of DC and CTC in medicated feedingstuff samples. Validation included determination of specificity, linearity, and repeatability. Mean recovery for spiked samples was 93.1% for CTC and 93.2% for DC. The results of validation of the analytical procedure proved that presented method is efficient, precise and useful for quantification of DC and CTC in medicated feedingstuffs.

2013 ◽  
Vol 340 ◽  
pp. 388-391 ◽  
Author(s):  
Xiang Ke Cao ◽  
Qing Zeng Qian ◽  
Jun Wang Tong ◽  
Qian Wang

By solid - phase extraction high performance liquid chromatography determination of nonylphenol, Octylphenol in aquatic product residues, to establish more accurate, fast, effective detection method. Sample is 3 trichloroacetic acid solution after extraction, using anion exchange solid phase extraction column purification by reversed phase high performance liquid chromatography method for determination. Column is Shim-pack VP-ODS 250mm x4.6mm, detection wavelength is225 nm, mobile phase of methanol - water ( volume ratio of 75:25), flow rate is 0.8 mL/min, injection volume is 20 ìL. Octylphenol, nonylphenol respectively in 0.14¡«97.63 ìg/mL ( R=0.9995),0.02¡«51.04 ì g/mL ( R=0.9997) concentration and peak area show a good linear relationship, octylphenol nonylphenol and the recovery is 87.9%¡«93.8%, relative standard deviation is 1.4%¡«3.8%. Solid - phase extraction high performance liquid chromatography method for determination of aquatic product of octylphenol and nonylphenol residue is accurate, rapid, high sensitivity, suitable for aquatic products of octylphenol nonylphenol and detection.


Sign in / Sign up

Export Citation Format

Share Document