scholarly journals Pengaruh Variasi Tegangan Tabung Sinar-X terhadap Signal to Noise Ratio (SNR) dengan Penerapan Anode Heel Effect menggunakan Stepwedge

2020 ◽  
Vol 22 (1) ◽  
pp. 20
Author(s):  
Puja Satwika Luh Gede ◽  
Ni Nyoman Ratini ◽  
Maghfirotul Iffah

It has been conducted research to determine the effect of X-ray tube voltage variation (kV) on Signal to Noise Ratio (SNR) values by applying the Anode Heel Effect using stepwedge with the addition of 1.5 mm thickness each step. The stepwedge used was 1.5-31.5 mm. The X-ray tube voltage variations used were 40, 50, 60, 70, 80, and 90 kV. Analysis of the effect of X-ray tube voltage variation on SNR values is determined using IMB SPSS Statistics 26 with a simple regression test. The test results showed that variations in X-ray tube voltage affect SNR values, where the greater the variation in X-ray tube voltage then the SNR value would get smaller. The optimal SNR value of 72.685 was obtained at a tube tension of 40 kV and a stepwedge thickness of 27.0 mm.

2022 ◽  
Vol 93 (1) ◽  
pp. 015006
Author(s):  
Xiaolong Zhao ◽  
Ming Ye ◽  
Zhi Cao ◽  
Danyang Huang ◽  
Tingting Fan ◽  
...  

2011 ◽  
Vol 110 (10) ◽  
pp. 109902 ◽  
Author(s):  
Michael Chabior ◽  
Tilman Donath ◽  
Christian David ◽  
Manfred Schuster ◽  
Christian Schroer ◽  
...  

2020 ◽  
Vol 4 (3) ◽  
pp. 75-82
Author(s):  
Ni Nyoman Ratini ◽  
I Made Yuliara ◽  
Windaryoto Windaryoto

It was researched on the application of Anoda Heel Effect (AHE) with a step wedge on the effect of Signal To Noise Ratio (SNR) on Computed Radiography (CR) has been carried out. This research was conducted on a 21 step wedge with two treatments, namely the application of AHE and without the application of AHE. This measurement is repeated three times on radiographs to obtain a total image of six images (without the application of AHE as many as three images and with the application of AHE as many as three images). The results of taking radiographs using AHE and without AHE were measured using the RadiAnt Dicom Viewer program. The SNR value on the step wedge image without the AHE application has an average of 26.89. The SNR value on the step wedge image using AHE is 60.54. The results of the correlation test (Pearson correlation test) on the SNR showed that there was a significant and very strong effect of the application of AHE on the step wedge on the SNR in CR (p-value <0.001 and the R-value ranging from 0.600 to 0.799).


2004 ◽  
Vol 78 (6) ◽  
pp. 915-919 ◽  
Author(s):  
N. Kalivas ◽  
L. Costaridou ◽  
I. Kandarakis ◽  
D. Cavouras ◽  
C.D. Nomicos ◽  
...  

Author(s):  
Timur Gureyev ◽  
David M. Paganin ◽  
Alex Kozlov ◽  
Harry Quiney

2005 ◽  
Vol 77 (20) ◽  
pp. 6563-6570 ◽  
Author(s):  
Zeng Ping Chen ◽  
Julian Morris ◽  
Elaine Martin ◽  
Robert B. Hammond ◽  
Xiaojun Lai ◽  
...  

2016 ◽  
Vol 22 (3) ◽  
pp. 536-543 ◽  
Author(s):  
Jong Seok Jeong ◽  
K. Andre Mkhoyan

AbstractAcquiring an atomic-resolution compositional map of crystalline specimens has become routine practice, thus opening possibilities for extracting subatomic information from such maps. A key challenge for achieving subatomic precision is the improvement of signal-to-noise ratio (SNR) of compositional maps. Here, we report a simple and reliable solution for achieving high-SNR energy-dispersive X-ray (EDX) spectroscopy spectrum images for individual atomic columns. The method is based on standard cross-correlation aided by averaging of single-column EDX maps with modifications in the reference image. It produces EDX maps with minimal specimen drift, beam drift, and scan distortions. Step-by-step procedures to determine a self-consistent reference map with a discussion on the reliability, stability, and limitations of the method are presented here.


2013 ◽  
Vol 55 (10) ◽  
pp. 548-552
Author(s):  
T Saravanan ◽  
K Arunmuthu ◽  
John Philip ◽  
B Purna Chandra Rao ◽  
T Jayakumar

Sign in / Sign up

Export Citation Format

Share Document