Depth dose measurement in water phantom for two X-ray energies (6MeV and 10MeV) in comparison with actual planning

2019 ◽  
pp. 1689-1693
Author(s):  
Raghdah H. Hasan ◽  
Samar I. Essa ◽  
Manwar A. AL-Naqqash

The purpose of this study is to measure doses delivered at different depths in water phantom at vertical position in comparison with the actual planning in order to verify the dose delivered to the tumor in addition to the measurement of the effect penumbra dose to assess the dose leaking to the healthy soft tissue.      Percentage depth dose (PDD) values was measured at field sizes (5×5,10×10,15×15, and 20×20) cm2, and the depth dose was measured between (0-16) cm deep at 4cm intervals, for both energies 6 MeV and 10 MeV X-ray beam. Other readings were taken at different distances 1cm and 2cm outside of the actual beam in orthogonal directions at depth of 4 cm. These measurements were designed to measure the penumbra dose produced outside the central beam.      Results show that the high similarity between water phantom and actual tissue for this reason water is taken as phantom for Quality Assurance (QA) and calculation the depth dose. The similar results may appear strange as the actual planning depth dose is taken in the chest wall where there is bone and soft tissue. The increase in the field size, increases the percentage of surface dose, this could be caused by an increase in the amount of scattering in the larger fields. There is almost no difference in depth dose between homogenous and non homogenous planning also similar to the water phantom. Because of higher photon energy 6MeV and 10MeV the bone has no influence in absorption from the soft tissue. A slight change in the depth dose with increase in the field size may be caused by the scattered radiation.

2018 ◽  
Vol 16 (37) ◽  
pp. 1-6
Author(s):  
Samar I. Essa

Radiotherapy is the branch of clinical medicine concerned with the application of ionizing radiation in the treatment of disease. And it is used to killing of cancer cells in a tissue using ionizing radiation while keeping the sparing of healthy cells at acceptable level. X-ray beams are used to deposit absorbed dose at depth within a patient at the site of the tumor. The aim of this work is studying the relationship between the depth dose and the field size in water phantom and homogenous actual planning. In our work, the dose distribution at different depths (zero-18 cm) deep at1cm interval treated with field size (10×10 and 20×20) cm2 were studied.Results show that high similarity between water phantom and actual planning for this reason water is taken as phantom for Quality Assurance (QA) and calculation the depth dose. When increasing the field size, the percentage of surface dose increases that this could be caused by an increase of the amount of scattering in the larger fields.Conclusion: There is almost no difference in depth dose between homogenous planning and water phantom.


PLoS ONE ◽  
2021 ◽  
Vol 16 (2) ◽  
pp. e0246845
Author(s):  
Su Chul Han ◽  
Jihun Kim ◽  
Min Cheol Han ◽  
Kyung Hwan Chang ◽  
Kwangwoo Park ◽  
...  

This study evaluates the changes occurring in the X-ray energy of a linear accelerator (LINAC) using a Daily QA3 detector system. This is accomplished by comparing the Daily QA3 results against those obtained using a water phantom. The X-energy levels of a LINAC were monitored over a duration of 1 month using the Daily QA3 system. Moreover, to account for the uncertainty, the reproducibility of the Daily QA3 ionization-chamber results was assessed by performing repeated measurements (12 per day). Subsequently, the energy-monitoring results were compared with the energy-change results calculated using the water-phantom percentage depth dose (PDD) ratio. As observed, the 6- and 10-MV beams experienced average daily energy-level changes of (-0.30 ± 0.32)% and (0.05 ± 0.38)%, respectively, during repeated measurements. The corresponding energy changes equaled (-0.30 ± 0.55)% and (-0.05 ± 0.48)%, respectively, when considering the measurement uncertainty. The Daily QA3 measurements performed at 6 MV demonstrated a variation of (2.15 ± 0.81)% (i.e., up to 3%). Meanwhile, the corresponding measurements performed using a water phantom demonstrated an increase in the PDD ratio from 0.577 to 0.580 (i.e., approximately 0.5%). At 10 MV, the energy variation in the Daily QA3 measurements equaled (-0.41 ± 0.82)% (i.e., within 1.5%), whereas the corresponding water phantom PDD ratio remained constant at 0.626. These results reveal that the Daily QA3 system can be used to monitor small energy changes occurring within radiotherapy machines. This demonstrates its potential for use as a secondary system for monitoring energy changes as part of the daily quality-assurance workflow.


2018 ◽  
Vol 18 (03) ◽  
pp. 280-284 ◽  
Author(s):  
Mohamed Bencheikh ◽  
Abdelmajid Maghnouj ◽  
Jaouad Tajmouati

AbstractAimThe purpose of this study is to introduce a new approach to assess the dosimetry quality of photon beam with energy and irradiation field size. This approach is based on percentage depth dose (PDD) fragmentation for investigating the dosimetry quality.Materials and methodsFor the investigation of the dosimetry quality of 6 and 18 MV photon beams, we have proceeded to fragment the PDD at different field sizes. This approach checks the overall PDD and is not restricted to the exponential decay regions, as per the International Atomic Energy Agency Technical Reports Series No 398 and the American Association of Physicist in Medicine Task Group 51 recommendations.Results and discussionThe 6 MV photon beam deposited more energy in the target volume than the 18 MV photon beam. The dose delivered by the 6 MV beam is greater by a factor of 1·5 than that delivered by the 18 MV beam in the build-up region and the dose delivered by the 6 MV beam is greater by a factor of 2·6 than that delivered by the 18 MV beam in the electronic equilibrium and the exponential decay regions.ConclusionThe dose measured at different points of the beam is higher for 6 MV than for 18 MV photon beam. Therefore, the 6 MV beam is more dosimetrically efficient than the 18 MV beam. Using the proposed approach, we can assess the dosimetry quality by taking into account overall PDD not only in the exponential decay region but also in the field.


2021 ◽  
Vol 229 ◽  
pp. 01041
Author(s):  
Kamal Saidi ◽  
Redouane El Baydaoui ◽  
Hanae El Gouach ◽  
Othmane Kaanouch ◽  
Mohamed Reda Mesradi

TrueBeam STx latest generation linear accelerators (linacs) installed at Sheikh Khalifa International University Hospital in Casablanca, Morocco. The aim of this is to present and compare the result of the Electron commissioning measurement on TrueBeam Stx and clinac iX installed at Sheikh Khalifa International University Hospital in Casablanca, Morocco. A compariaon of eMC calculations and measurements for TrueBeam Stx were evaluated. Dosimetric parameters are systematically measured using a large water phantom 3D scanning system MP3 Water Phantom (PTW, Freiburg, Germany). The data of the electron beams commissioning including depth dose curves for each applicator, depth dose curves without applicator and the profile in air for a large field size 40x 40cm2, and the Absolute Dose (cGy/MU) for each applicator. All the data were examined and compared for five electron beams (E6MeV, E9MeV, E12MeV, E16MeV and E20MeV) of Varian’s TrueBeam STx and Clinac iX machines. A comparison, between measurement PDDs and calculated by the Eclipse electron Monte Carlo (eMC) algorithm were performed to validate Truebeam Stx commissioning. All this measurements were performed with a Roos and Markus plane parallel chamber. Our measured data indicated that electron beam PDDs from the TrueBeam Stx machine are well matched to those from our Varian Clinac iX machine. Significant differences between TrueBeam and Clinac iX were found in in‐air profiles and open field output. Maximum depth dose for the TrueBeam Stx and Clinac iX for the following energies (6, 9, 12, 16, 20 MeV) are respectively (1.15; 1.89; 2.6; 3.1; and 2.35) and (1.24; 1.95; 2.70; 2.99 and 2.4cm). For the TrueBeam Stx and Clinac iX the quality index R50 for applicator 15x15 cm2 are in the tolerance intervals. Surface dose increases by increasing energy for both machines. The Absolute Dose (cGy/MU) calibrated for both machine in Dmax at 1cGy/MU for the reference field size cone 15x15 cm2. Bremsstrahlung tail Rp per energy levels as follows for the TrueBeam Stx : 6 MeV – 2.85 cm, 9 MeV – 4.28 cm, 12 MeV – 5.97 cm, 16 MeV – 7.88 cm and 20 MeV – 9.86 cm. and for the Clinac iX : 6 MeV – 2.86 cm, 9 MeV – 4.32 cm, 12 MeV – 5.96 cm, 16 MeV – 7.93 cm and 20 MeV – 10.08 cm. A good agreement between modeled and measured data is observed.


1993 ◽  
Vol 34 (1) ◽  
pp. 92-98 ◽  
Author(s):  
J. Persliden ◽  
M. Sandborg

Conversion factors between the energy imparted to the patient in pediatric radiography and air collision kerma integrated over beam area are presented. The values have been derived from Monte Carlo calculations in soft tissue phantoms and extend results published earlier to cover children from early infancy to the age of 15 years. Variations related to phantom size as well as to focus-phantom distance, radiation field size, orientation of view (a.p., lateral), tube potential, and beam filtration are given. We show that the conversion factor increases with increasing half-value layer of the X-ray beam and the anterioposterior width of the simulated child. Increasing the focus-phantom distance increases the conversion factor, while increasing the field size decreases the factors due to more scattered radiation escaping laterally from the phantom.


2016 ◽  
Vol 27 (1) ◽  
pp. 18-20
Author(s):  
Uum Yuliani ◽  
Ridwan Ramdani ◽  
Freddy Haryanto ◽  
Yudha Satya Perkasa ◽  
Mada Sanjaya

Varian linac modeling has been carried out to obtain Percentage Depth Dose (PDD) and profiles using variations gantry angle 0o, 15o, 30o , 45o in the vertical axis of the surface, field size 10x10 cm2, photon beam 4 MV and Monte Carlo simulations. Percentage Depth Dose and profile illustrates dose distributions in a phantom water measuring 40x40x40 cm3, changes gantry is one of the factors that determine the distribution of the dose to the patient research shows changes in Dmax in the Percentage Depth Dose is affected by changes in the angle gantry resulted in the addition of the area build up so it can be used for therapy in the region and produce skin sparing effects that can be used to protect the skin from exposure to radiation. The graph result is profiles obtained show lack simetrisan in areas positive quadrant has a distribution of fewer doses than the quadrant of negative as well as the slope of the surface so that it can be used for some cases treatments that require a depth and a certain slope, dose calculations are more accurate and can minimize side effects.


2010 ◽  
Vol 37 (6Part21) ◽  
pp. 3274-3274
Author(s):  
T Gorjiara ◽  
R Hill ◽  
Z Kuncic ◽  
C Baldock

Author(s):  
Mohd Fahmi Mohd Yusof ◽  
Nur Natasha Md Othman ◽  
Reduan Abdullah ◽  
Ahmad Bazlie Abdul Kadir ◽  
Husaini Salleh