In vitro validation of a 3-dimensional transrectal ultrasound system for prostate biopsiess

2007 ◽  
Vol 30 (4) ◽  
pp. 77
Author(s):  
Derek Cool ◽  
Shi Sherebrin ◽  
Jonathan Izawa ◽  
Joseph Chin ◽  
Aaron Fenster

Introduction: Transrectal ultrasound (TRUS) prostate biopsy (Bx) is currently confined to 2D information to both target and record 3D Bx locations. Accurate placement of Bx needles cannot be verified without 3D information, and recording Bx sites in 2D does not provide sufficient information to accurately guide the high incidence of repeat Bx. We have designed a 3D TRUS prostate Bx system that augments the current 2D TRUS system and provides tools for biopsy-planning, needle guidance, and recording of the biopsy core locations entirely in 3D. Methods: Our Bx system displays a 3D model of the patient’s prostate, which is generated intra-procedure from a collection of 2D TRUS images, representative of the particular prostate shape. Bx targets are selected, needle guidance is facilitated, and 3D Bx sites are recorded within the 3D context of the prostate model. The complete 3D Bx system was validated, in vitro, by performing standard ten-core Bx on anatomical phantoms of two patient’s prostates. The accuracy of the needle-guidance, Bx location recording, and 3D model volume and surface topology were validated against a CT gold standard. Results: The Bx system successfully reconstructed the 3D patient prostate models with a mean volume error of 3.2 ± 7.6%. Using the 3D system, needles were accurately guided to the pre-determined targets with a mean error of 2.26 ± 1.03 mm and the 3D locations of the Bx cores were accurately recorded with a mean distance error of 1.47 ± 0.79 mm. Conclusion: We have successfully developed a 3D TRUS prostate biopsy system and validated the system in vitro. A pilot study has been initiated to apply the system clinically.

2021 ◽  
Author(s):  
Davut Ibrahim Mahcicek ◽  
Dursun Korel Yildirim ◽  
Gokce Kasaci ◽  
Ozgur Kocaturk

Abstract In clinical routine, the prostate biopsy procedure is performed with the guidance of transrectal ultrasound (TRUS) imaging to diagnose prostate cancer. However, the TRUS-guided prostate biopsy brings reliability concerns due to the lack of contrast difference between prostate tissue and lesions. In this study, a novel hydraulic needle delivery system that is designed for performing MRI-guided prostate biopsy procedure with transperineal approach is introduced. The feasibility of the overall system was evaluated through in-vitro phantom experiments under an MRI guidance. The in vitro experiments performed using a certified prostate phantom (incorporating MRI visible lesions). MRI experiments showed that overall hydraulic biopsy needle delivery system has excellent MRI compatibility (SNR Loss < 3%), provides acceptable targeting accuracy (average 2.05±0.46 mm) and procedure time (average 40 minutes).


2008 ◽  
Author(s):  
Jeffrey Bax ◽  
Derek Cool ◽  
Lori Gardi ◽  
Jacques Montreuil ◽  
Elena Gil ◽  
...  

2009 ◽  
Vol 28 (11) ◽  
pp. 1561-1568 ◽  
Author(s):  
Yujun Guo ◽  
Priya N. Werahera ◽  
Ramkrishnan Narayanan ◽  
Lu Li ◽  
Dinesh Kumar ◽  
...  

2009 ◽  
Vol 8 (2) ◽  
pp. 99-103 ◽  
Author(s):  
Valerie H. Chen ◽  
Vladimir Mouraviev ◽  
Janice M. Mayes ◽  
Leon Sun ◽  
John F. Madden ◽  
...  

2016 ◽  
Vol 54 (12) ◽  
pp. 1343-1404
Author(s):  
LS Spitzhorn ◽  
MA Kawala ◽  
J Adjaye
Keyword(s):  

2020 ◽  
Author(s):  
H Gaitantzi ◽  
C Cai ◽  
S Asawa ◽  
K Böttcher ◽  
M Ebert ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document