scholarly journals Pencegahan Kesalahan Alarm dalam Sistem Pendeteksi Dini Kebakan dan Pemadaman Berbasis Internet of Things

Author(s):  
Mumuh Muharam ◽  
Melda Latif ◽  
Baharuddin Baharuddin ◽  
Ibnum Richaflor

False alarm in fire detection can cause a huge loss. False alarm is generated by unwanted signal of smoke detector such as outdoor smoke or smoking. Therefore, it is designed a system that can reduce false alarm. The purposed system is built based on three components, those are sensors, actuators and data communication.  Sensors are smoke, flame and camera sensor. Smoke sensor is used as the first thing to sense a signal from the system that warns the system there is a fire. Flame sensor and camera are used to confirm that a signal of fire whether false alarm or not. Internet of Things (IoT) is applied to control the system. The result show that the system is applicable.

2012 ◽  
Vol 605-607 ◽  
pp. 1851-1854
Author(s):  
Yan Qiu Wang ◽  
Yan Wen Wang ◽  
Chun Mei Pei ◽  
Xiu Qing Yang ◽  
Hai Rong Ye

Characteristics of fire detection signal are proposed that, in fire case non-fire signals caused by other factors can not be separated from fire signals and in non-fire case non-fire signals may produce changes similar to fire signals. An intelligent algorithm is pointed out to reduce false alarm rate and miss alarm rate, it can improve fire alarm accuracy. The intelligent algorithm includes digital filter, sensitivity autoregulation, drift aotocompensation and rising rate analysis, and it is useful in practical engineering.


Author(s):  
EVA AISAH HW ◽  
ROHMAT TULLOH ◽  
SUGONDO HADIYOSO ◽  
DADAN NUR RAMADAN

ABSTRAKKebakaran rumah seringkali disebabkan oleh kelalaian manusia. Oleh karena itu diperlukan sebuah sistem yang dapat mendeteksi kebakaran secara online realtime. Pada studi ini, dirancang dan diimplementasikan sebuah sistem pendeteksi kebakaran dengan sejumlah sensor untuk mengukur beberapa parameter lingkungan. Sistem ini dilengkapi dengan pengambil keputusan menggunakan metode fuzzy logic. Parameter lingkungan yang diukur mencakup suhu ruangan, asap dan api yang kemudian dapat dimonitor secara real-time melalui web interface menggunakan Internet of Things platform. Pengujian menunjukkan bahwa detektor dapat mendeteksi api dengan jarak hingga 100 cm dengan akurasi mencapai 100%. Pengujian sensor suhu menunjukkan akurasi 98.79%, sementara itu detektor asap memperoleh akurasi 77.81%. Sistem ini mampu mengirimkan data dengan rata-rata delay transmisi 0.62 detik. Sistem usulan ini diharapkan dapat menyediakan pemantauan kondisi suatu ruangan secara real-time.Kata kunci: Kebakaran, Real-Time, Deteksi, Fuzzy, Internet Of Things ABSTRACTHouse fires are often caused by human error. Therefore, we need a system that can detect fires online real-time. In this study, a fire detection system with a number of sensors is designed and implemented to measure several environmental parameters. This system is equipped with a decision maker using the fuzzy logic method. The environmental parameters measured include room temperature, smoke and fire which can then be monitored in real time via a web interface using the Internet of Things platform. Tests show that the detector can detect fires with a distance of up to 100 cm with an accuracy of up to 100%. The temperature sensor test shows an accuracy of 98.79%, while the smoke detector generates an accuracy of 77.81%. This system is capable of sending data with an average transmission delay of 0.62 seconds. This proposed system is expected to provide realtime monitoring of the condition of a room.Keywords: Fire, Real-time, detection, Fuzzy, internet of things


Internet of Things (IoT) is a connection of interconnected any things deployed in different applications. The IoT is emerging as a technique for real-time monitoring the environment like Earthquake early detection. Snow level monitoring, forest fire detection, Gas level monitoring in a Smart Kitchen. IoT based sensor network need secure communication, processing, analytics and transient storage for better monitoring of smart environments. In this article, the authors proposed a secure framework for data collection and further processing from the sensors network to the core of the network using Fog-Cloud based architecture. The paper implemented the proposed framework taking different sensors deploy in an IoT based smart kitchen environment. For experimental purpose, Raspberry Pi used as a fog node and local cloud server to monitor the environment in real-time, SQLite is used as buffer storage. The experimental setup and result show that the proposed framework is secure to monitoring in a sensor network.


2011 ◽  
Vol 8 (2) ◽  
pp. 155-161 ◽  
Author(s):  
Jovan Ristic ◽  
Dragana Radosavljevic

Analogue (and addressable) fire detection systems enables a new quality in improving sensitivity to real fires and reducing susceptibility to nuisance alarm sources. Different decision algorithms types were developed with intention to improve sensitivity and reduce false alarm occurrence. At the beginning, it was free alarm level adjustment based on preset level. Majority of multi-criteria decision work was based on multi-sensor (multi-signature) decision algorithms - using different type of sensors on the same location or, rather, using different aspects (level and rise) of one sensor measured value. Our idea is to improve sensitivity and reduce false alarm occurrence by forming groups of sensors that work in similar conditions (same world side in the building, same or similar technology or working time). Original multi-criteria decision algorithms based on level, rise and difference of level and rise from group average are discussed in this paper.


2006 ◽  
Vol 15 (2) ◽  
pp. 197 ◽  
Author(s):  
Francisco Castro Rego ◽  
Filipe Xavier Catry

In the management of forest fires, early detection and fast response are known to be the two major actions that limit both fire loss and fire-associated costs. There are several inter-related factors that are crucial in producing an efficient fire detection system: the strategic placement and networking of lookout towers, the knowledge of the fire detection radius for lookout observers at a given location and the ability to produce visibility maps. This study proposes a new methodology in the field of forest fire management, using the widely accepted Fire Detection Function Model to evaluate the effect of distance and other variables on the probability that an object is detected by an observer. In spite of the known variability, the model seems robust when applied to a wide variety of situations, and the results obtained for the effective detection radius (13.4 km for poor conditions and 20.6 km for good conditions) are in general agreement with those proposed by other authors. We encourage the application of the new approach in the evaluation or planning of lookout networks, in addition to other integrated systems used in fire detection.


2021 ◽  
pp. 118-123
Author(s):  
В.Н. Круглеевский ◽  
В.В. Вислогузов ◽  
A.A. Таранцев ◽  
С.Н. Турусов

В настоящей статье рассматриваются вопросы развития пожарных извещателей, контролирующих появление дыма, превышение заданного значения температуры и скорости ее роста, наличие угарного газа и использующих мультикритериальные алгоритмы для оценки обоснованности сигналов тревоги. Анализируются результаты проведенных отечественными организациями сравнительных испытаний мультикритериальных и традиционных «пороговых» пожарных извещателей и возможности их применения на судах в составе систем пожарной сигнализации. Определено, что при повторении одних и тех же модельных очагов пожаров зафиксированные значения контролируемых параметров отличались незначительно. При этом для каждого модельного очага можно было обнаружить свои характерные черты. Сделан вывод о том, что внедрение мультикритериальных алгоритмов обработки информации в судовые системы обнаружения пожаров не только сокращает время обнаружения пожара, но и позволяет расширить функциональные возможности системы. Используя мультикритериальные пожарные извещатели в системах пожарной сигнализации можно будет распознавать, что именно горит: дизельное топливо, ветошь, изоляция электрического кабеля или что-либо другое. Отмечается, что требования к судовым мультикритериальным системам сигнализации обнаружения пожара нашли свое отражение в Правилах классификации и постройки морских судов Российского морского регистра судоходства. This article discusses the development of fire detectors that control the appearance of smoke, the excess of a given temperature and the rate of its growth, the presence of carbon monoxide and use multicriteria algorithms to assess the validity of alarm signals. The results of comparative tests of multicriteria and traditional fire detectors conducted by domestic organizations and the possibility of their use on ships as part of fire alarm systems are analyzed. It was determined that when the same model fires were repeated, the recorded values of the controlled parameters differed slightly. At the same time, for each model focus, it was possible to detect its own characteristic features. It is concluded that the introduction of multicriteria algorithms for information processing in ship fire detection systems not only reduces the time of fire detection, but also allows you to expand the functionality of the system. Using multi-criteria fire detectors in fire alarm systems,it will be possible to recognize what exactly is burning: diesel fuel, rags, electrical cable insulation, or anything else. It is noted that the requirements for ship multicriteria fire detection alarm systems are reflected in the Rules for the Classification and Construction of Marine Vessels of the Russian Maritime Register of Shipping.