scholarly journals Design and Analysis of Earthing System for Wind Turbine Generators from Lightning Discharge Currents

2021 ◽  
Author(s):  
◽  
Raghavender Goud Deshagoni

<p>Currently, wind power production is undergoing rapid growth due to the escalating interest in green energy generation. As a result, generators are now choosing to locate wind turbine generators (WTGs) in areas where there is more lightning activity, and earthing problems can be exacerbated further by the soil resistivity being higher than where turbines are usually located. In addition, the desire to capture more energy from the wind has given way to larger WTGs, further increasing the probability of lightning strikes to the structure. This heightened regularity has emphasized the need for an effective grounding system, capable of dissipating the large currents discharged by the lightning into the lightning protection system. This “effective grounding system” must offer a low impedance by limiting the ground potential rise, which is critical due to the wider frequency content of the lightning discharge currents (ranging from DC to several MHz).  The design of an effective grounding system for WTGs depends on the calculation of the minimum length of the earth electrodes, soil resistivity and its frequency-dependency, and the impact of WTG foundation. The calculation of the length of earth electrodes needs an accurate measurement of soil resistivity and modeling of the measured resistivity. Hence, this research considers the measured soil resistivity values of an Australian wind farm and presents an analysis of the soil stratification to identify the optimum soil models. The influence of the soil layers on the WTG grounding system is also investigated to install the earth electrodes. As the resistivity of the soil is frequency-dependent, an analysis is performed to evaluate the effect of the frequency-dependent soil parameters on the WTG grounding system at various frequencies of lightning discharge current. In addition, the impact of the rebar of the WTG foundation on the grounding system is evaluated as the rebar shares the lightning discharge currents. The effective length of the earth electrodes is frequency-dependent, and rebar determines the impedance of the grounding system at high-frequencies. The next step in the grounding design is the design of earth electrodes.  The current dissipating capacity of the earth electrodes depends on soil resistivity, dimensions of the earth electrodes, and burial depth of the electrodes. However, the traditional practice of designing earth electrodes is based on the soil resistivity alone, considering the uniform soil resistivity model. The conventional method of designing earth electrodes based on the uniform soil resistivity is not practical due to non-homogeneous behavior of the soil resistivity. To enhance the WTG earthing system design, this research proposes a novel method to calculate the minimum length of an earth electrode for uniform and two-layer based soil models considering electrode dimensions and burial depth. The grounding impedance achieved when electrode lengths are calculated using the proposed method is compared to grounding impedance values computed using the conventional method. This comparison shows that the proposed method is an improvement on the current convention. In particular, the proposed method gives a grounding impedance value of less than 10 Ω at low frequencies for all soil resistivity values. This results in a reduction in the potential rise of up to 64% compared to the peak potential value in the conventional method. The benefits offered by the proposed method mean that it can be employed to calculate electrode lengths for the required resistance values based on soil resistivity, electrode dimensions, and burial depth. Such a design may serve as a starting point for an engineer wishing to design a WTG earthing system.  Another challenge noted is the practice of assessing the effectiveness of the WTG grounding system. The conventional method is based on achieving a low-frequency resistance of 10 Ω according to the standard IEC 61400-24 and the performance of the grounding system at high frequencies is not considered. Hence, identification of the high-frequency components of the relevant lightning discharge currents is important to understand the performance of the grounding system. An analysis of the wind turbine earthing system for different lightning discharge current wave shapes is performed considering the lightning current waveforms and parameters mentioned in the IEC 61400-24 standard and evaluated the various frequency components and their influence on the WTG grounding system. It is identified that the impedance of the grounding system is minimum for the first short positive stroke current parameters for all the soil resistivity values compared to the first short negative and the subsequent short current wave shapes, although the peak current magnitude is highest for this wave shape. From the analysis of WTG grounding system based on various parameters, this research presents a procedure for assessing the effectiveness of WTG lightning protection system with a focus on the grounding system. It is identified that the effectiveness of the grounding system can be improved by proper design of earth electrodes, optimum soil stratification, and selecting low resistivity soil sites. Finally, various earth electrode configurations are evaluated to identify the better electrode configuration for WTG grounding system.  This thesis provides an in-depth analysis of WTG grounding systems to protect WTGs from lightning strikes. The contributions of this research will help wind farm architects to design effective grounding systems leading to effective lightning protection systems. Finally, the contributions will help to increase the adoption of wind power, resulting in more renewable energy generation. The outcome of this research can be realized to reduce the downtime of WTGs by incorporating the effectiveness of lightning protection system component into the wind farm optimization process. Also, a generalized procedure for calculating the minimum length of earth electrodes for all the soil models can be developed in the future.</p>

2021 ◽  
Author(s):  
◽  
Raghavender Goud Deshagoni

<p>Currently, wind power production is undergoing rapid growth due to the escalating interest in green energy generation. As a result, generators are now choosing to locate wind turbine generators (WTGs) in areas where there is more lightning activity, and earthing problems can be exacerbated further by the soil resistivity being higher than where turbines are usually located. In addition, the desire to capture more energy from the wind has given way to larger WTGs, further increasing the probability of lightning strikes to the structure. This heightened regularity has emphasized the need for an effective grounding system, capable of dissipating the large currents discharged by the lightning into the lightning protection system. This “effective grounding system” must offer a low impedance by limiting the ground potential rise, which is critical due to the wider frequency content of the lightning discharge currents (ranging from DC to several MHz).  The design of an effective grounding system for WTGs depends on the calculation of the minimum length of the earth electrodes, soil resistivity and its frequency-dependency, and the impact of WTG foundation. The calculation of the length of earth electrodes needs an accurate measurement of soil resistivity and modeling of the measured resistivity. Hence, this research considers the measured soil resistivity values of an Australian wind farm and presents an analysis of the soil stratification to identify the optimum soil models. The influence of the soil layers on the WTG grounding system is also investigated to install the earth electrodes. As the resistivity of the soil is frequency-dependent, an analysis is performed to evaluate the effect of the frequency-dependent soil parameters on the WTG grounding system at various frequencies of lightning discharge current. In addition, the impact of the rebar of the WTG foundation on the grounding system is evaluated as the rebar shares the lightning discharge currents. The effective length of the earth electrodes is frequency-dependent, and rebar determines the impedance of the grounding system at high-frequencies. The next step in the grounding design is the design of earth electrodes.  The current dissipating capacity of the earth electrodes depends on soil resistivity, dimensions of the earth electrodes, and burial depth of the electrodes. However, the traditional practice of designing earth electrodes is based on the soil resistivity alone, considering the uniform soil resistivity model. The conventional method of designing earth electrodes based on the uniform soil resistivity is not practical due to non-homogeneous behavior of the soil resistivity. To enhance the WTG earthing system design, this research proposes a novel method to calculate the minimum length of an earth electrode for uniform and two-layer based soil models considering electrode dimensions and burial depth. The grounding impedance achieved when electrode lengths are calculated using the proposed method is compared to grounding impedance values computed using the conventional method. This comparison shows that the proposed method is an improvement on the current convention. In particular, the proposed method gives a grounding impedance value of less than 10 Ω at low frequencies for all soil resistivity values. This results in a reduction in the potential rise of up to 64% compared to the peak potential value in the conventional method. The benefits offered by the proposed method mean that it can be employed to calculate electrode lengths for the required resistance values based on soil resistivity, electrode dimensions, and burial depth. Such a design may serve as a starting point for an engineer wishing to design a WTG earthing system.  Another challenge noted is the practice of assessing the effectiveness of the WTG grounding system. The conventional method is based on achieving a low-frequency resistance of 10 Ω according to the standard IEC 61400-24 and the performance of the grounding system at high frequencies is not considered. Hence, identification of the high-frequency components of the relevant lightning discharge currents is important to understand the performance of the grounding system. An analysis of the wind turbine earthing system for different lightning discharge current wave shapes is performed considering the lightning current waveforms and parameters mentioned in the IEC 61400-24 standard and evaluated the various frequency components and their influence on the WTG grounding system. It is identified that the impedance of the grounding system is minimum for the first short positive stroke current parameters for all the soil resistivity values compared to the first short negative and the subsequent short current wave shapes, although the peak current magnitude is highest for this wave shape. From the analysis of WTG grounding system based on various parameters, this research presents a procedure for assessing the effectiveness of WTG lightning protection system with a focus on the grounding system. It is identified that the effectiveness of the grounding system can be improved by proper design of earth electrodes, optimum soil stratification, and selecting low resistivity soil sites. Finally, various earth electrode configurations are evaluated to identify the better electrode configuration for WTG grounding system.  This thesis provides an in-depth analysis of WTG grounding systems to protect WTGs from lightning strikes. The contributions of this research will help wind farm architects to design effective grounding systems leading to effective lightning protection systems. Finally, the contributions will help to increase the adoption of wind power, resulting in more renewable energy generation. The outcome of this research can be realized to reduce the downtime of WTGs by incorporating the effectiveness of lightning protection system component into the wind farm optimization process. Also, a generalized procedure for calculating the minimum length of earth electrodes for all the soil models can be developed in the future.</p>


2020 ◽  
Vol 11 (7-2020) ◽  
pp. 66-72
Author(s):  
Liubov A. Belova ◽  

The earth-termination system for towers of ground-based wind turbines in addition to protective and functional grounding provides lightning protection grounding, which is especially important since the wind turbine is susceptible to lightning strikes. If insufficient protective measures are taken, the risk of damage to a wind turbine due to a lightning strike increases. Therefore, a well-thought-out built-in grounding system for wind turbine towers is needed, which would function as necessary and guarantee long-term mechanical strength and corrosion resistance. The configuration of grounding systems for wind turbines is discussed in IEC 61400-24, which deals with the topic of lightning protection for wind turbines, including detailed information on the choice of lightning protection measures and surge protection. It is advisable to create a lightning protection concept at the initial stage of planning a wind turbine in order to avoid later costly repairs and retrofitting.


Author(s):  
Muhammad Adnan ◽  
Zulkurnain Adul Malek ◽  
Nur Syazwani Mohd Din ◽  
Muhammad Irfan Jambak ◽  
Zainuddin Nawawi ◽  
...  

<table width="593" border="1" cellspacing="0" cellpadding="0"><tbody><tr><td valign="top" width="387"><p>The role of the grounding system in the safety of the power system and protection of personnel is obvious during an unexpected short circuit or lightning discharge at the substation. The aim of this work is to analyze the effects of several parameters: lightning impulse front time, soil resistivity and types of grid materials on the grounding system of the Substation. The ground potential rise (GPR), touch voltage and step voltage of a 50 m x 60 m grounding grid buried at a depth of 0.5 m were computed using CDEGS when injected by impulse with different front times. Results show that the shorter the front time of lightning impulse waveform, the higher the value of GPR, touch voltage and step voltage. Meanwhile, when the value of soil resistivity is increased, the value of GPR, touch voltage and step voltage is also increased. Lastly, different types of grid conductor materials give different values of GPR, touch voltage and step voltage. However, it can be said that the differences are too small to be of any significance.</p><p> </p></td></tr></tbody></table>


2014 ◽  
Vol 584-586 ◽  
pp. 2695-2699
Author(s):  
Wen Bo Yu ◽  
Xiao Lin Luo ◽  
Bing Chen ◽  
Wen Xiang Wang

Wind power has become one of the most potential and vital green energy sources. Location of the wind farm has a better wind resource,and it is also relatively open. Lightning accident in the wind farm happened occasionally, in order to avoid the situation, which impulse current damages the wind turbine, in the accident, lightning protection grounding system of wind turbine is essential .In this paper, according to the experience of Dongshan wind farm project , the method of how to design the wind turbines and booster station grounding grid as required, the calculation of ground resistance and specific measures to reduce grounding resistance of wind turbine grounding device are discussed.


Author(s):  
Xu Pei-Zhen ◽  
Lu Yong-Geng ◽  
Cao Xi-Min

Background: Over the past few years, the subsynchronous oscillation (SSO) caused by the grid-connected wind farm had a bad influence on the stable operation of the system and has now become a bottleneck factor restricting the efficient utilization of wind power. How to mitigate and suppress the phenomenon of SSO of wind farms has become the focus of power system research. Methods: This paper first analyzes the SSO of different types of wind turbines, including squirrelcage induction generator based wind turbine (SCIG-WT), permanent magnet synchronous generator- based wind turbine (PMSG-WT), and doubly-fed induction generator based wind turbine (DFIG-WT). Then, the mechanisms of different types of SSO are proposed with the aim to better understand SSO in large-scale wind integrated power systems, and the main analytical methods suitable for studying the SSO of wind farms are summarized. Results: On the basis of results, using additional damping control suppression methods to solve SSO caused by the flexible power transmission devices and the wind turbine converter is recommended. Conclusion: The current development direction of the SSO of large-scale wind farm grid-connected systems is summarized and the current challenges and recommendations for future research and development are discussed.


Author(s):  
Toshiki Chujo ◽  
Yoshimasa Minami ◽  
Tadashi Nimura ◽  
Shigesuke Ishida

The experimental proof of the floating wind turbine has been started off Goto Islands in Japan. Furthermore, the project of floating wind farm is afoot off Fukushima Prof. in north eastern part of Japan. It is essential for realization of the floating wind farm to comprehend its safety, electric generating property and motion in waves and wind. The scale model experiments are effective to catch the characteristic of floating wind turbines. Authors have mainly carried out scale model experiments with wind turbine models on SPAR buoy type floaters. The wind turbine models have blade-pitch control mechanism and authors focused attention on the effect of blade-pitch control on both the motion of floater and fluctuation of rotor speed. In this paper, the results of scale model experiments are discussed from the aspect of motion of floater and the effect of blade-pitch control.


Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2319
Author(s):  
Hyun-Goo Kim ◽  
Jin-Young Kim

This study analyzed the performance decline of wind turbine with age using the SCADA (Supervisory Control And Data Acquisition) data and the short-term in situ LiDAR (Light Detection and Ranging) measurements taken at the Shinan wind farm located on the coast of Bigeumdo Island in the southwestern sea of South Korea. Existing methods have generally attempted to estimate performance aging through long-term trend analysis of a normalized capacity factor in which wind speed variability is calibrated. However, this study proposes a new method using SCADA data for wind farms whose total operation period is short (less than a decade). That is, the trend of power output deficit between predicted and actual power generation was analyzed in order to estimate performance aging, wherein a theoretically predicted level of power generation was calculated by substituting a free stream wind speed projecting to a wind turbine into its power curve. To calibrate a distorted wind speed measurement in a nacelle anemometer caused by the wake effect resulting from the rotation of wind-turbine blades and the shape of the nacelle, the free stream wind speed was measured using LiDAR remote sensing as the reference data; and the nacelle transfer function, which converts nacelle wind speed into free stream wind speed, was derived. A four-year analysis of the Shinan wind farm showed that the rate of performance aging of the wind turbines was estimated to be −0.52%p/year.


Sign in / Sign up

Export Citation Format

Share Document