Personificación de Modelos de Elementos Finitos de Cuerpo Humano

Author(s):  
Ana Piqueras Lorente ◽  
Johan Iraeus ◽  
Francisco José López Valdés ◽  
Ana Isabel Lorente Corellanos ◽  
Óscar Juste Lorente ◽  
...  

The goal of this study was to quantify the effect of improving the geometry of a human body model on the accuracy of the predicted kinematics for 4 post-mortem human subject sled tests. Three modifications to the computational human body model THUMS were carried out to evaluate if subject personification can increase the agreement between predicted and measured kinematics of post-mortem human subjects in full frontal and nearside oblique impacts. The modifications consisted of: adjusting the human body model mass to the actual subject mass, morphing it to the actual anthropometry of each subject and finally adjustment of the model initial position to the measured position in selected post-mortem human subject tests. A quantitative assessment of the agreement between predicted and measured response was carried out by means of CORA analysis by comparing the displacement of selected anatomical landmarks (head CoG, T1 and T8 vertebre and H-Point). For all three scenarios, the more similar the human body model was to the anthropometry and posture of the sled tested post-mortem human subject, the more similar the predictions were to the measured responses of the post-mortem human subject, resulting in higher CORA score.

Author(s):  
Bu S. Park ◽  
Sunder S. Rajan ◽  
Leonardo M. Angelone

We present numerical simulation results showing that high dielectric materials (HDMs) when placed between the human body model and the body coil significantly alter the electromagnetic field inside the body. The numerical simulation results show that the electromagnetic field (E, B, and SAR) within a region of interest (ROI) is concentrated (increased). In addition, the average electromagnetic fields decreased significantly outside the region of interest. The calculation results using a human body model and HDM of Barium Strontium Titanate (BST) show that the mean local SAR was decreased by about 56% (i.e., 18.7 vs. 8.2 W/kg) within the body model.


2009 ◽  
Vol 23 (17) ◽  
pp. 3586-3590 ◽  
Author(s):  
NUTTACHAI JUTONG ◽  
APIRAT SIRITARATIWAT ◽  
DUANGPORN SOMPONGSE ◽  
PORNCHAI RAKPONGSIRI

Electrostatic discharge (ESD) effects on GMR recording heads have been reported as the major cause of head failure. Since the information density in hard-disk drives has dramatically increased, the GMR head will be no longer in use. The tunneling magnetoresistive (TMR) read heads are initially introduced for a 100 Gbit/in2 density or more. Though the failure mechanism of ESD in GMR recording heads has not been explicitly understood in detail, a study to protect from this effect has to be done. As the TMR head has been commercially started, the ESD effect must be considered. This is the first time that the TMR equivalent circuit has been reported in order to evaluate the ESD effect. A standard human body model (HBM) is discharged across R+ and R- where the capacitances of flex on suspension (FOS) are varied. It is intriguingly found that the electrical characteristics of the TMR head during the discharge period depend on the discharge position. This may be explained in terms of the asymmetry impedance of TMR by using adapted Thevenin's theory. The effect of FOS components on TMR recording heads is also discussed.


Sign in / Sign up

Export Citation Format

Share Document