scholarly journals THE EFFECT OF CULTIVATION CONDITIONS ON GROWTH AND THERAPEUTIC ACTIVITY OF PLEUROTUS ERYNGII

Author(s):  
T. A. Krupodorova ◽  
V. Yu. Barshteyn
2005 ◽  
pp. 269-276
Author(s):  
Mirjana Stajic ◽  
Sonja Duletic-Lausevic ◽  
Jelena Vukojevic

Pleurotus eryngii produced laccase (Lac) both under conditions of submerged fermentation (SF) and solid-state fermentation (SSF) using all of the investigated carbon and nitrogen sources, while significant peroxidases production occurred only under SSF conditions. The highest levels of Lac activity were found under SF conditions of dry ground mandarine peels (999.5 U/l). After purification of extracellular crude enzyme mixture of P. eryngii which was grown under SF conditions with dry ground mandarine peels it was revealed two peaks of Lac activity and one peak of activity against phenol red in absence of external Mn2+ which was very low (1.4 U/l). Results obtained by purification also showed that the levels of phenol red oxidation in absence of external Mn2+ were higher than phenol red oxidation levels in presence of external Mn2+. In the medium with the best carbon source for Lac production (dry ground mandarine peels), (NH4)2SO4, with a nitrogen concentration of 20 mM, was the most optimum nitrogen source among 8 investigated sources.


1987 ◽  
Vol 26 (03) ◽  
pp. 143-146 ◽  
Author(s):  
H. Fill ◽  
M. Oberladstätter ◽  
J. W. Krzesniak

The mean activity concentration of1311 during inhalation by the nuclear medicine personnel was measured at therapeutic activity applications of 22 GBq (600 mCi) per week. The activity concentration reached its maximum in the exhaled air of the patients 2.5 to 4 hours after oral application. The normalized maximum was between 2 • 10−5 and 2 • 10−3 Bq-m−3 per administered Bq. The mean activity concentration of1311 inhaled by the personnel was 28 to 1300 Bq-m−3 (0.8 to 35 nCi-rrf−3). From this the1311 uptake per year was estimated to be 30 to 400 kBq/a (x̄ = 250, SD = 50%). The maximum permitted uptake from air per year is, according to the German and Austrian radiation protection ordinances 22/21 µiCi/a (= 8 • 105 Bq/a). At maximum 50% and, on the average, 30% of this threshold value are reached. The length of stay of the personnel in the patient rooms is already now limited to such an extent that 10% of the maximum permissible whole-body dose for external radiation is not exceeded. Therefore, increased attention should be paid also to radiation exposure by inhalation.


Sign in / Sign up

Export Citation Format

Share Document