scholarly journals Stability indicating RP-HPLC method development and validation for the simultaneous determination of Sofosbuvir and Velpatasvir in tablet dosage forms

2017 ◽  
Vol 5 (04) ◽  
pp. 10-16 ◽  
Author(s):  
Jahnavi Bandla ◽  
S. Ganapaty

Stability indicating RP-HPLC method was developed for the simultaneous quantitation of Sofosbuvir and Velpatasvir in its pharmaceutical dosage form and validated. The drugs were separated on Discovery C18 (150mm x 4.6mm, 5μ) column using 0.01N potassium dihydrogen phosphate buffer and acetonitrile (50:50%v/v) as mobile phase on isocratic mode. The mobile phase is pump into the column at flow rate of 1.0ml/min and column oven temperature is maintained at 30ºC. The drugs were detected at a wavelength 240nm. The retention time for Sofosbuvir and Velpatasvir were found to be 2.32min and 3.34min respectively. The developed method is validated in accordance with ICH guidelines. The method was found to be accurate, precise, specific and robust. The method obeys Beer’s law at a concentration range of 100μg/ml – 600μg/ml of Sofosbuvir and 25μg/ml – 150μg/ml of Velpatasvir, with correlation coefficient of 0.999 for both the drugs. The drugs were found to be stable and less prone to degradation when they are subjected to various stress conditions.

Author(s):  
Ramesh Jayaprakash ◽  
Senthil Kumar Natesan

Objective: The present study was aimed to develop a rapid, accurate, linear, sensitive and validate stability-indicating high performance liquid chromatographic [RP-HPLC] method for determination of vildagliptin and metformin in pharmaceutical dosage form.Methods: The chromatographic separation was performed on kromasil-C18 column [4.5 x 250 mm; 5 µm] using a mobile phase consisting of 0.05 mmol potassium dihydrogen phosphate buffer: acetonitrile [80:20 v/v], [pH adjusted to 3.5 using orthophosphoric acid]. The flow rate is 0.9 ml/min and the detection was carried out at 263 nm.Results: The chromatographic condition, the peak retention time of metformin and vildagliptin were found to be 2.215 min and 2.600 min respectively. Stress testing was performed in accordance with an international conference on harmonization [ICH] Q1A R2 guidelines. The method was validated as per ICH Q2 R1 guidelines. The calibration curve was found to be linear in the concentration range of 5-17.5 µg/ml and 50-175 µg/ml for vildagliptin and metformin. The limit of detection and quantification was found to be 0.0182 µg/ml and 0.0553 µg/ml for vildagliptin and 0.4451 µg/ml and 1.3490 µg/ml for metformin respectively.Conclusion: A new sensitive, simple and stability indicating reverse-phase high-performance liquid chromatography [RP-HPLC] method has been developed and validated for the determination of vildagliptin and metformin. The proposed method can be used for routine determination of vildagliptin and metformin.


2020 ◽  
Vol 13 (1) ◽  
pp. 44-51
Author(s):  
S.Afreen Sultana ◽  
Patta. Salomi ◽  
T. VimalakKannan ◽  
K.Ravindra Reddy

In present study, accurate, precise, rapid and sensitive stability indicting HPLC-UV method has been established for quantification of Telmisartan, Cilnidipine and Chlorthalidone simultaneously in Tablet and bulk. Telmisartan, Cilnidipine and Chlorthalidone were resoluted on Sunsil C18 column (4.6mmx250mm; 5μm) using mobile phase containing Acetonitrile and Potassium dihydrogen phosphate in 50:50(v/v) ratio with flow rate of 1ml/min at 238 nm. Concentrations were linear over the range of 40-120 μg/ml for Telmisartan, 10-30 μg/ml for Cilnidipine and 6.25-18.75 μg/ml for Chlorthalidone. The percentage recovery was found to be 99.70-100.51% for Telmisartan, 98.41-100.49% for Cilnidipine and 99.34-100.48% for Chlorthalidone. % RSD for peak area was 0.069% for Telmisartan, 0.058% for Cilnidipine and 0.057% for Chlorthalidone shows that the proposed method is precise. Force-degradation studies have not shown any observable change in the results and hence the proposed method is stability indicating and hence the method is suitable for routine analysis of Telmisartan, Cilnidipine and Chlorthalidone in bulk and tablet dosage form.


Author(s):  
Krutika Patel ◽  
Sudheer Kumar Verriboina ◽  
S.G. Vasantharaju

A simple, accurate, specific and stability-indicating RP-HPLC method was developed for simultaneous determination of chlorzoxazone, diclofenac sodium and paracetamol, using C18 Vydac Monomeric 120A (250 × 4.6mm, 5μ) at 40ºC. The mobile phase contains a mixture of 20mM potassium dihydrogen phosphate buffer (pH 6.2 adjusted with potassium hydroxide) and acetonitrile (30:70 v/v). The flow rate was 1ml/min and detection was carried out at 275nm using PDA detector. The retention time of paracetamol, chlorzoxazone and diclofenac sodium were 3.28mins, 13.27mins and 15.61mins respectively. The analytical curve was linear over a concentration range of 0.65- 6.5μg/ml for paracetamol, 1-10μg/ml for chlorzoxazone and 0.1-1μg/ml for diclofenac sodium. The drugs in bulk and tablet were subjected to acid and alkali hydrolysis, oxidation, thermal and photolytic degradation. This method can be successfully employed for simultaneous quantitative analysis of Chlorzoxazone, Diclofenac sodium and Paracetamol in bulk drug and tablet formulation.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (05) ◽  
pp. 68-71
Author(s):  
A Lakshmana Rao ◽  
◽  
T. Prasanthi ◽  
E. L Anusha

A simple, accurate and precise RP-HPLC method was developed for the simultaneous estimation of the linagliptin and empagliflozin in tablet dosage form. Chromatogram was run through Kromasil 250 x 4.6 mM, 5mM column, mobile phase containing 0.1% o-phosphoric acid buffer and acetonitrile in the ratio of 60:40%v/v was pumped through column at a flow rate of 1 mL/min. The optimized wavelength was 230 nm. Retention times of linagliptin and empagliflozin were found to be 2.759 min and 2.139 min. %RSD of the Linagliptin and Empagliflozin were found to be 0.5 and 0.6 respectively. Percentage assay was obtained as 99.91% and 100.15% for linagliptin and empagliflozin, respectively. LOD, LOQ values obtained for linagliptin and empagliflozin were 0.23 μg/ml and 0.44 μg/mL and 0.70 μg/mL and 1.34 μg/mL, respectively. Thus, the current study showed that the developed RP-HPLC method is sensitive and selective for the estimation of linagliptin and empagliflozin in combined dosage form.


Author(s):  
R Sireesha ◽  
P Syam Vijayakar ◽  
V Pavan Kumar ◽  
B Sivagami ◽  
Pranabesh Sikdar ◽  
...  

In the present work RP-HPLC method has been developed for the quantitative estimation of Terbinafine hydrochloride in bulk drug and pharmaceutical formulations. A rapid and sensitive RP-HPLC Method with PDA detection (220 nm) for routine analysis of in Bulk drug and Pharmaceutical formulation was developed. Chromatography was performed with mobile phase containing a mixture of Potassium dihydrogen phosphate and Acetonitrile (65:35 v/v) with flow rate 1.5 ml/min. The linearity was found to be in the range of 50-150 µg/ml with (r2=0.999). The proposed method was validated by determining sensitivity, accuracy, precision, LOD, LOQ and system suitability parameters according to ICH guidrelines.


Author(s):  
Bhoomi Dineshkumar Patel ◽  
Nidhi J. Dharsandiya ◽  
Ankit Chaudhary

The objective of the study is a simple, precise and accurate stability RP-HPLC method has been developed and subsequently validated for the estimation of Teneligliptin and its impurity in tablet formulation. The adequate separation was carried out using Grace Smart C18 column (250mm x 4.6mm, 5?m particle size), mixture of 0.05M Potassium dihydrogen phosphate PH 4.0 and Acetonitrile 80:20 % v/v as a mobile phase with a flow rate of 1 ml/min and the effluent was monitored at 242 nm using PDA detector. The retention time of Teneligliptin, Impurity B and Impurity G were 7.443 min, 6.650 min and 8.473 min respectively. Linearity for Teneligliptin, Impurity B and Impurity G were found in the range of 500-3000 µg/ml (R2 = 0.998), 5-15 µg/ml (R2 = 0.994) and 5-15 µg/ml (R2 = 0.998) respectively. The accuracy of the present method was evaluated at 50%, 100% and 150%. The % recoveries of drug were found to be in range of 99.315 ± 0.283 for Teneligliptin. Precision studies were carried out and the RSD values were less than two. The method was found to be robust. The proposed method was found to be specific, accurate, precise and robust can be used for simultaneous estimation of these drugs in tablet dosage form.