Heat Transfer Analysis on V Trough Concentrator Based Solar Air Heater with Flexible Absorber Unit

2021 ◽  
Vol 57 (1) ◽  
pp. 68-80
Author(s):  
B. A. Sunil Raj ◽  
M. Eswaramoorthy
1988 ◽  
Vol 110 (2) ◽  
pp. 145-155 ◽  
Author(s):  
F. Issacci ◽  
Y. Zvirin ◽  
G. Grossman

A theoretical method is presented for the investigation of a reflective fin solar air heater. The heat transfer processes include radiation in both the solar and IR spectra, mixed convection (forced and natural) in the air and conduction in the fins. The governing equations have been solved numerically to obtain the velocity and temperature fields in the developing and developed flow regions. The efficiency of the finned structure is then calculated, and the results of a parametric study are shown. It has been found that natural convection effects are significant and strong buoyancy leads to separation and reversed flow. The efficiency increases with lower surface emissivity and lower thermal conductivity of the fins.


Author(s):  
Sumer Singh Patel ◽  
Atul Lanjewar

Abstract The present experimental study is concerned with heat transfer analysis of air flowing in solar air heater duct with a gap in V-rib with symmetrical gap and staggered ribs geometry. The investigated parameters are Reynolds number (Re) of 4000–14,000, relative roughness pitch (p/e) of 12, relative roughness height (e/Dh) of 0.043, angle of attack (α) of 60 deg, relative staggered rib pitch (p′/p) of 0.65, relative gap size (g/e) of 4, relative staggered rib size (r/e) of 4, relative gap position of additional gap in each symmetrical rib elements (d/w) of 0.65, relative gap size of additional gap in each symmetrical rib elements (g′/e) of 1, number of main gaps (Ng) of 1, 2, 3, 4, and number of additional gap (ng) varying from 1 to 5. Fourteen roughened absorber plates were tested. The maximum enhancement in Nusselt number (Nu) and friction factor (f) was 2.34 and 2.79 times that of smooth surface corresponding to the number of main gaps (Ng) of 4 with the number of additional gaps (ng) of 4. The performance of the gap in V-rib with symmetrical gap and staggered rib geometry has been compared with the existing latest V-rib geometry and smooth surface. The proposed gap in V-rib with symmetrical gap and staggered ribs geometry has a better performance than the existing latest V-rib geometry. The following correlations have been developed for heat transfer and friction factor in terms of roughness and operating parameters. Heat transfer:Nur=0.0073(Re)0.9788(Ng)0.2790(ng)0.0184exp[−0.1678(ln(Ng))2]exp[−0.0129(ln(ng))2] Friction factor:fr=0.0477(Re)−0.0678(Ng)0.5919(ng)−0.0562exp[−0.4922(ln(Ng))2]exp[−0.0487(ln(ng))2]


Sign in / Sign up

Export Citation Format

Share Document