Sample Preparation, Identification, and Determination of Twelve Macrolides in Raw Food Materials and Food Products Using High-Resolution Mass Spectrometry

2019 ◽  
Vol 74 (2) ◽  
pp. 63-69 ◽  
Author(s):  
V. G. Amelin ◽  
D. S. Bol’shakov
2020 ◽  
Vol 86 (8) ◽  
pp. 23-31
Author(s):  
V. G. Amelin ◽  
D. S. Bolshakov

The goal of the study is developing a methodology for determination of the residual amounts of quaternary ammonium compounds (QAC) in food products by UHPLC/high-resolution mass spectrometry after water-acetonitrile extraction of the determined components from the analyzed samples. The identification and determination of QAC was carried out on an «UltiMate 3000» ultra-high-performance liquid chromatograph (Thermo Scientific, USA) equipped with a «maXis 4G» high-resolution quadrupole-time-of-flight mass spectrometric detector and an ion spray «ionBooster» source (Bruker Daltonics, Germany). Samples of milk, cheese (upper cortical layer), dumplings, pork, chicken skin and ground beef were used as working samples. Optimal conditions are specified for chromatographic separation of the mixture of five QAC, two of them being a mixture of homologues with a linear structure (including isomeric forms). The identification of QAC is carried out by the retention time, exact mass of the ions, and coincidence of the mSigma isotopic distribution. The limits for QAC detection are 0.1 – 0.5 ng/ml, the determination limits are 1 ng/ml for aqueous standard solutions. The determinable content of QAC in food products ranges within 1 – 100 ng/g. The results of analysis revealed the residual amount of QAC present in all samples, which confirms data of numerous sources of information about active use of QAC-based disinfectants in the meat and dairy industry. The correctness of the obtained results is verified by introduction of the additives in food products at a level of 10 ng/g for each QAC. The relative standard deviation of the analysis results does not exceed 0.18. The duration of the analysis is 30 – 40 min.


2021 ◽  
Vol 87 (10) ◽  
pp. 18-25
Author(s):  
T. M. Baygildiev ◽  
A. V. Braun ◽  
M. F. Vokuev ◽  
I. V. Rybalchenko ◽  
I. A. Rodin

Detection of biologically active components in mixtures of complex composition which include biological fluids (blood, urine, etc.) is the most difficult problem of the analytical chemistry and requires the use of modern highly informative research methods. One of the most effective and universal ways to study the structure of unknown substances is the method of liquid chromatography- high resolution mass spectrometry that combines the possibility of highly selective separation of the mixtures under study, the reliable detection of unknown substances and high sensitivity of the procedure. We propose a method for the simultaneous extraction of highly polar biomarkers of nitrogen mustard — N-triethanolamine (TEA), N-ethyl diethanolamine (EDEA) and N-methyldiethanolamine (MDEA) — from urine with subsequent determination by HPLC and detection by high resolution tandem mass spectrometry. The mass spectra of fragmentation of protonated molecular ions of TEA, EDEA, and MDEA have been studied and possible structural formulas of the fragment ions are given. The sample preparation of urine and mass spectrometric detection in the multiple reaction monitoring mode were optimized. The five-fold dilution with deionized water was chosen as a method of urine sample preparation for analysis. Separation of the components was performed in the reversed-phase chromatography mode with retention times for TEA, EDEA, and MDEA of 2.00, 2.05, and 1.92 min, respectively. The time required to complete all steps of the urine sample analysis did not exceed 25 min. The detection limits in urine were 1 ng/ml for TEA and 2 ng/ml for EDEA and MDEA. The developed approach provides determination of the fact of application of specific nitrogen mustard in enquiry of possible exposure of living organism to the blister agents.


Sign in / Sign up

Export Citation Format

Share Document